start_h3.fm
Starting Up HiPath 3000
Starting Up HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300
Procedure: Reinitialization
Proceed as follows if measures to expand the system configuration require reinitialization of
the numbering plan:
Step
1.
Disconnect the system
from the power supply.
Check that the system is
de-energized.
Expand as required.
2.
Connect system to pow-
er supply
5-14
Activity
A continuous numbering plan is generated (as was the
case when the system was first initialized).
Notes:
Description
Changes to the extension numbers result in chang-
es to the individual, extension-specific data.
Only those ports provided for in accordance with
the maximum configuration are activated if the
maximum line configuration is exceeded (too many
trunk boards).
A mixture of subscriber line circuits and trunk lines
on one S
board can result in gaps in line number-
0
ing. This is because all board ports are initially acti-
vated as trunks and are only subsequently reconfig-
ured.
S
station: If stations are connected to an S
0
(S
bus), their station numbers result from the MSN
0
programmed in the telephone, regardless of the
connection.
If no MSN is programmed on a telephone or if no
MSN can be programmed, the system uses a de-
fault MSN. The default MSN can be administered
by S
port (HiPath 3000/5000 Manager E).
0
The system does not assign the MSN until the S
port is configured on the "EURO bus"; the MSN can
be read out via administration.
HiPath 3000/5000 V9, Service documentation
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
board
0
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents