Service
Guided Maintenance
Table 12-7
HiPath 3000 Class B Error Messages
No.
HiPath 3000/
5000 Manager E:
Event Log Entry
Error Class 23 – Messages from the Device Handler Network
23-060 !system hold, no
buffer available
23-061 !Check config
rules for TMDID
Error Class 26 – Board Administration Messages
26-000 !unknown card
type
26-001 !card out of ser-
vice
26-002 !More than al-
lowed amount of
cards
26-003 !other card type
than old card type
26-004 !card in service
12-82
Meaning
System hold, no
more free buffer
available.
For U.S. only: TM-
DID boards incor-
rectly configured.
Unknown board.
The specified
board is out of or-
der.
The maximum
number permitted
for a certain board
type is exceeded.
Incompatible
board type. The
slot is already pre-
assigned with a dif-
ferent board type.
The specified
board is operation-
al.
Required Measures
Set up a trace using infor-
mation from BLS.
Create a stack dump.
Save a snapshot.
Check TMDID board con-
figuration using informa-
tion from Page 4-48 and
correct if necessary.
System does not support
the board type. Replace
the board with a valid
board type or remove it
from the system.
None
Reduce the number of
boards of this board type.
Note the maximum config-
uration.
Replace the board or use
Assistant T to delete the
preassigned board type so
that the new board is rec-
ognized.
None
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Nur für den internen Gebrauch
Note
The board may
be too old or too
new for the sys-
tem.