Optipoint Recorder Adapter - Siemens HiPath 3000 Series Service Documentation

Table of Contents

Advertisement

Nur für den internen Gebrauch
10.5.3.5

optiPoint recorder adapter

The optiPoint recorder adapter allows an external recorder or a second headset to be connect-
ed.
Warning: The called party must be informed that the call is being recorded.
1
Figure 10-51
optiPoint recorder adapter
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Assignment of both connection jacks:
1
MW6 port for recorder
2
Contacts 2+3 and 4+5 are bridged
internally.
Recorders to be connected must meet the following electrical re-
quirements:
Input impedance: >10 kΩ
Frequency progression: 300 to 3000 Hz ± 3 dB
Beep tone level: -26 dBm to -18 dBm at a 600 Ω load
Max. input level: 650 mVeff from a 600 Ω source
2
MW4 port for second headset
Pin
Signal
1
Free
2
NF
3
NF
4
NF
5
NF
6
Free
Pin
Signal
1
Tx–
2
Rx
3
Rx
4
Tx+
wclient.fm
Workpoint Clients
optiPoint 500
6
1
4
1
10-103