Siemens HiPath 3000 Series Service Documentation page 413

Table of Contents

Advertisement

Nur für den internen Gebrauch
"Silent Reversal", which is used to register the beginning and end of an outgoing call in dif-
ferent countries, is also supported. It can be activated with HiPath 3000/5000 Manager E
(Settings menu: Lines/networking ... -> Trunks -> (double-click) Parameters -> MSI flags -
> Flags -> Silent Reversal).
ÜFS direct inward dialing:
The Austrian direct inward dialing system ÜFS is not supported.
Installation instructions in the U.S. and Canada:
According to U.S. and Canadian installation instructions, analog trunks must be connected
over fuse elements in compliance with UL 497A or CSA C22.2 No. 226.
Front panel, LEDs
Two LEDs indi-
cating the board
status:
LED (red)
LED (green)
Figure 3-98
TMANI8 – front panel, LEDs (S30810-Q2327-Xxx)
An additional shielding panel is not required on the front side of this board, because the EMC
shield is already provided by the front panel.
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Boards for HiPath 3000
Jumper
X100
3 2 1
1
2
3
X101
boards.fm
Peripheral boards
Backplane
port
3-281