Figure 3-87
CAS cable shield contacts
To ensure sufficient electromagnetic shielding (according to EN 55022), both shielded
CAS cables must be contacted at the appropriate points on the HiPath 3550/HiPath 3350.
Procedure:
Fix the cable shielding (B) for both CAS cables (A) via cable binder (C) to the T tongue (D)
of the housing, so a continuously conductive contact is created between the conductive
tape on the cable shielding and the housing (see figure).
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
TCAS-2, TCASR-2 (for selected countries only) – Impedance Converter
F31505-E1-A146
boards.fm
Boards for HiPath 3000
Peripheral boards
3-255