Siemens HiPath 3000 Series Service Documentation page 1053

Table of Contents

Advertisement

Nur für den internen Gebrauch
Table 12-7
HiPath 3000 Class B Error Messages
No.
HiPath 3000/
5000 Manager E:
Event Log Entry
20-037 !CDR Adm. read
failed
20-038 !CDR Data de-
tected
20-039 !CDR Data over-
flow
20-040 !CDR Mem. allo-
cated
20-041 !CDR Mem. re-
leased
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Meaning
Error while reading
administration
structure from the
advanced call data
memory.
An advanced call
data memory was
found during sys-
tem startup.
The advanced call
data memory is
full.
The advanced call
data memory was
successfully creat-
ed.
The advanced call
data memory was
temporarily re-
leased.
Required Measures
Set up a trace using infor-
mation from BLS.
Create a stack dump.
Save a snapshot.
None
Read out call data.
None
None
service.fm
Service
Guided Maintenance
Note
This message is
issued after the
call data memo-
ry has been
completely read
out. It must be
followed by the
"CDR Mem. allo-
cated" message.