Siemens HiPath 3000 Series Service Documentation page 1051

Table of Contents

Advertisement

Nur für den internen Gebrauch
Table 12-7
HiPath 3000 Class B Error Messages
No.
HiPath 3000/
5000 Manager E:
Event Log Entry
18-021 HLM:Lic failure
period stopped li-
cense ok
18-022 HLM: Lic failure
period stopped
default lic
Error Class 19 – Network Services Messages
19-002 !SNTP-Server not
responding
Error Class 20 – Call Processing Messages
20-002 !RS232: DSR not
Ready
20-011 !RS232: DSR
ready
20-013 !not connected
ways
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Meaning
HiPath License
Management: The
connection be-
tween the system
and HiPath 5000
RSM is reestab-
lished.
HiPath License
Management: The
connection be-
tween the system
and HiPath 5000
RSM was not rees-
tablished within 30
days. All licenses
were deleted.
No connection to
the SNTP server.
The RS232/V.24
interface is out of
order.
The RS232/V.24
interface is now
operational.
The maximum
number of connec-
tion paths permit-
ted has been ex-
ceeded.
Required Measures
None
Check and reestablish the
connection to HiPath 5000
RSM.
Load license from the CLS
and relicense the system.
Check the application and
the connection.
Check the interface, the
line, and the application.
None
Use the project planning
tool to test the system con-
figuration.
Set up a trace using infor-
mation from BLS.
Create a stack dump.
Save a snapshot.
service.fm
Service
Guided Maintenance
Note
12-77

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents