Nur für den internen Gebrauch
3.3.18

SLMAV8, SLMAV24

NOTE
>
Danger of damage to property due to surge voltage. The required lightning protec-
tion measures must be taken for this board, see Section 2.1.2, "Lightning Protec-
tion".
Introduction
For HiPath 3000/5000 V8 or later, the following boards can be used to connect analog stations
(analog telephones, Fax Group 3, etc.) in HiPath 3800:
SLMAV8 (S30810-Q2227-X100) = 8 analog T/R interfaces
SLMAV24 (S30810-Q2227-X200) = 24 analog T/R interfaces
The SLMAV8 and SLMAV24 boards are successor modules for the following boards:
SLMA (S30810-Q2191-C300)
SLMA2 (S30810-Q2246-X)
SLMA8 (S30810-Q2191-C100)
SLMAE [SLMAE200] (S30810-Q2225-X200)
SLMAE8 (S30810-Q2225-X100)
Automatic migration to the boards SLMAV8 and SLMAV24 is not possible. The slot in HiPath
3800 must be released via HiPath 3000 Manager E
Main features
Code Receiver: A code receiver is available for each T/R interface (permits DTMF dialing at
analog telephones). This guarantees that all analog terminals connected are fully accessible.
CLIP: These boards support calling name identification presentation (CLIP).
External analog extensions:
External analog extensions may only be connected via the SLMAV board.
For U.S. only: The connection of external analog extensions via OPS signaling (OPS: Off-
Premises-Station) is not supported.
Ring voltage: The SLMAV board generates its own ring voltage of 71 V
age generator is therefore not required.
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
boards.fm
Boards for HiPath 3000
Peripheral boards
. An external ring volt-
eff
3-189