power_calc.fm
Identifying System Power Requirements

Checking Whether the Output of a Power Supply Unit is Sufficient

D.7
Checking Whether the Output of a Power Supply Unit is
Sufficient
Apart from the secondary power requirements, the power output must also be checked to en-
sure that the maximum possible output of the system's power supply unit is sufficient. For this,
the power requirement on the 5-V output format and on the -48-V output format must be exam-
ined separately.
Caution
7
To guarantee smooth system operation, the nominal output of the power supply unit
at the 5-V output and at the -48-V output must be greater than the respective sec-
ondary power requirement.
Procedure
Proceed as follows to identify the secondary power requirement of a system:
1.
Determine secondary power requirement at the 5-V output
5 V power requirement of the boards/components used
=
secondary power requirement at the 5-V output
2.
Determine secondary power requirement at the -48-V output
–48-V power requirement of the boards/components used
+
power requirement of connected workpoint clients (analog and digital telephones),
key modules and adapters
=
secondary power requirement at the -48-V output
Using the specified values, check whether the total power requirement exceeds the maximum
possible output of the power supply unit at the 5-V output or at the -48-V output. If this is the
case, you have the following options:
HiPath 3800
The number of LUNA2 power supply units can be increased.
HiPath 3550 with UPSC-D
The maximum nominal output of the –48-V output can be increased from 53 W to 110 W
by using the external power supply Powerbox PB3000 with LUNA2.
HiPath 3350 with UPSC-D
The maximum nominal output of the –48-V output can be increased from 53 W to 110 W
by using the external power supply Powerbox PB3000 with LUNA2.