Table 12-7
HiPath 3000 Class B Error Messages
No.
HiPath 3000/
5000 Manager E:
Event Log Entry
32-046 EVM error during
DM
32-049 DH_EVM->reset
EVM
32-052 AM com during
DM
32-053 Memory Full
32-055 No Pill File select-
ed
32-058 Philips API ER-
ROR
32-059 I2C failure detect-
ed
Error Class 40 – Messages Concerning MMC Module Access
40-000 !MMC not
plugged or defec-
tive
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Meaning
EVM: EVM error
during Data Mode.
EVM: System -
DH_EVM -> reset
EVM.
EVM: AM Com-
mand during Data
Mode.
EVM: Memory Full.
EVM: No Pill File
Selected.
EVM: Philips API
ERROR.
EVM: I2C failure
detected.
MMC module can-
not be accessed
during startup.
Required Measures
Check available languag-
es on the EVM.
Load a language if neces-
sary.
MMC module is not
connected: –> Con-
nect the MMC.
MMC module is faulty:
–> Replace the MMC.