Hipath 3500 Board Power Requirement - Siemens HiPath 3000 Series Service Documentation

Table of Contents

Advertisement

power_calc.fm
Identifying System Power Requirements

HiPath 3500 Board Power Requirement

D.4
HiPath 3500 Board Power Requirement
Table D-7
Nominal Output of the HiPath 3500 Power Supply Units
Power Supply Unit
UPSC-DR
Powerbox PB3000 with
LUNA2
You must check whether the total power requirement of the boards used and the
>
workpoint clients connected exceeds the maximum possible output of the UPSC-DR
with or without Powerbox PB3000. Section D.7 contains a sample calculation.
Table D-8
HiPath 3500 Board Power Requirement
Board or Component
BS3/1
BS3/3
CBRC
(including subboards) S30810-Q2935-Z301
HXGR3
IVMS8R
Fan for HiPath 3500
P
DM1
SLAD8R
SLU8R
STLS4R
STRBR
T
CASR-2
TLA4R
TMGL4R
TST1
D-8
Part Number
S30122-K7373-A900
S30122-K7373-M900
S30177-U773-X with
S30122-K7686-M1
Part Number
S30807-H5482-X
S30807-H5485-X
S30810-K2943-Z
S30122-K7379-Z
S30807-Q5692-X100
S30810-K2956-X300
S30817-K922-Z301
S30817-K924-Z313
S30817-Q932-Z
S30810-K2945-X
S30817-Q923-Zxxx
S30810-K2918-Z
S30810-K2919-Z
Nur für den internen Gebrauch
Max. Nominal Output in W
5 V
40.0
Net Power Requirement in
5 V
7.0
10.0
2.6
2.0
0.8
1.0
0.5
4.5
0.2
1
5.7
0.8
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
–48 V
53.0
110
W
–48 V
2.0
3.0
0.5
0.3
1.4
5.0
1.0
1
0.1