Siemens HiPath 3000 Series Service Documentation page 736

Table of Contents

Advertisement

start_h5.fm
Startup and Administration HiPath 5000
GetAccount
Data record structure
Table 6-7
GetAccount - Data Record Structure
No.
Pos.
Length
1
1-8
2
9-16
3
17-19
4
20-22
5
23-28
6
29-33
7
34-41
8
42-66
25
9
67-77
11
10
78
11
79-89
11
12
90-100
11
13 101-105
14 106-109
15
110
16
111
6-54
8
Date of call end
Format DD.MM.YY, for example "13.09.00"
8
Time of call end
Format hh:mm:ss, for example "14:14:00"
3
Trunk number
right-aligned with leading blanks, for example " 1"
3
Node ID for HiPath 3000 (matches the configuration in HiPath 3000/
5000 Manager E)
right-aligned with leading blanks
6
Internal extension number
right-aligned with leading blanks
5
Call duration in seconds
8
Call duration
Format hh:mm:ss, for example "00:04:34
For incoming calls: external caller number
For outgoing calls: external call number dialed including the call-
by-call number
left-aligned with succeeding blanks
Number of tariff units
right-aligned with leading blanks
1
Call type
1: incoming
2: outgoing (default)
Account code ACCT
left-aligned with succeeding blanks
MSN used
5
Trunk
right-aligned with leading blanks
4
LCR Selected Route (corresponds to configuration in HiPath 3000/
5000 Manager E)
right-aligned with leading blanks
1
CR
1
LF
Nur für den internen Gebrauch