Siemens HiPath 3000 Series Service Documentation page 494

Table of Contents

Advertisement

boards.fm
Boards for HiPath 3000
Options
Table 3-176
ANI4 (for selected countries only) - LED Statuses for Trunk 1
LED
Red LED - Checksum Status
On
The received caller ID signal has a checksum error.
The LED is reset after the next correct caller ID mes-
sage is received.
Off
Checksum is OK.
ANI4 module contact assignments
Table 3-177
ANI4 (for selected countries only) - Contact Assignments
Contact
Connector X3
Component Side
1
2
b-wire (ring), trunk 1
3
4
b-wire (ring), trunk 2
5
6
b-wire (ring), trunk 3
7
8
b-wire (ring), trunk 4
9
10
GMZ= Call charging module assignment
3-362
Meaning
--
--
--
--
--
GMZ
Connector X3
Solder Side
Not assigned
--
a-wire (tip), trunk 1
--
a-wire (tip), trunk 2
--
a-wire (tip), trunk 3
--
a-wire (tip), trunk 4
--
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Nur für den internen Gebrauch
Action
If the red LED is on after ev-
ery call: the FSK signal is
provided, but is not Bellcore-
compliant on the customer
side. This must be corrected
by the service provider.
Connector X4
a-wire (tip), trunk 1
b-wire (ring), trunk 1
a-wire (tip), trunk 2
b-wire (ring), trunk 2
a-wire (tip), trunk 3
b-wire (ring), trunk 3
a-wire (tip), trunk 4
b-wire (ring), trunk 4