Nur für den internen Gebrauch
4.1.8
Loading the System Software and Installing Subboards on the
CBSAP
Caution
7
Always wear an antistatic wristband when working on the system (especially when
handling boards). Connect the wristband to the slide-in shelf in the cabinet using the
alligator clip.
The boards should be installed in the cabinets as described in Section 4.1.5.
The central control boards are not always fully equipped when delivered. Optional plug-in
boards are packaged individually.
See Section 3.2.3 for information on slots for subboards on the central control board CBSAP.
Caution
7
Place the central control board on a flat surface before installing subboards.
The spacing bolts supplied guarantee the correct insertion of the subboard, so you
should always mount them (see Figure 3-7).
Otherwise you may damage the board.