10.5.4

optiPoint 500 key modules and adapters power supply

Power is generally supplied to optiPoint 500 telephones by the system via the U
When certain optiPoint 500 key modules and adapters are used, the power supply from the
system is not adequate.
Table 10-8 indicates which optiPoint 500 key modules require an additional external power sup-
ply. In this case, the local power supply units described in Section 10.8.1.1 are used.
Table 10-8
Additional External Power Supply for optiPoint 500 Key Modules and Adapters
optiPoint 500 key modules
optiPoint 500 Adapters
optiPoint key module
optiPoint BLF
optiPoint analog adapter
optiPoint ISDN adapter
optiPoint phone adapter
optiPoint acoustic adapter
optiPoint recorder adapter
1
It is assumed that only one key module or adapter is implemented on each optiPoint 500 telephone. An additional external
power supply may be required if several key modules and adapters are implemented on an optiPoint 500 telephone or the
maximum U
interface range is reached by the optiPoint 500 telephone. The telephone test described in Section 12.4.11
P0/E
will establish whether or not additional power is required from a local power supply.
2
The local power supply is series-connected to the optiPoint 500 telephone: the "digital" RJ6 jack on the local power supply
must be connected to the optiPoint 500 telephone. The other RJ6 jack must be connected to the U
system.
3
The local power supply is connected directly to the optiPoint BLF: one of the two RJ6 jacks on the local power supply unit
must be connected with the center jack (indicated by the symbol of a power supply unit) on the optiPoint BLF. A local power
supply can supply a maximum of two optiPoint BLFs.
4
An additional external power supply is required if the floating contacts on the optiPoint acoustic adapters are being used.
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Is an additional external power
supply required?
generally not required
required
required
generally not required
generally not required
required
generally not required
Plug-in power supply
unit connection
1
series-connected
connected directly
series-connected
1
series-connected
1
series-connected
4
series-connected
1
series-connected
wclient.fm
Workpoint Clients
optiPoint 500
interfaces.
P0/E
2
3
2
2
2
2
2
interface on the
P0/E
10-105

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents