power_calc.fm
Identifying System Power Requirements
Identifying the Primary System Power Requirement
Sample calculation for a HiPath 3550
1.
Determine overall secondary power requirement
power requirements of the boards/
components used =
+
power requirement of connected
workpoint clients, key modules and
adapters =
=
overall secondary power requirement
=
2.
Identifying primary power requirement
overall secondary power requirement
=
+
UPSC-D requirement =
Allow for the degree of efficiency of the
power supply unit:
The primary power requirement of HiPath 3550 with the expansion mentioned
amounts to approximately 112.4 W.
D-18
7.50 W
1 x CBCC
12.80 W
1 x HXGS3 (including ventilator
kit)
0.90 W
1 x TS2N
2.40 W
3 x SLU8
2.60 W
1 x 8SLA
5.00 W
1 x SLC16N
24.00 W
12 x BS3/1
4.32 W
6 x optiPoint 500 advance
8.40 W
12 x optiPoint 500 basic
2.40 W
8 x optiPoint 500 entry
0.00 W
2 x Hicom Attendant BLF
0.00 W
2 x optiPoint BLF
0.40 W
8 x optiPoint key module
0.50 W
2 x optiPoint acoustic adapter
1.80 W
6 x analog workpoint clients
74.43 W
74.43 W
12.00 W
86.43 W
x 1.3 = 112.4 W