Siemens HiPath 3000 Series Service Documentation page 636

Table of Contents

Advertisement

inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Digital and analog trunk and subscriber lines of the HiPath 3550 and HiPath 3350 (wall
housing)
If
HiPath 3550
HiPath 3350
Guide the trunk and subscriber lines of all ports connected on a board
through a ferrite sleeve (C39022-Z7000-C6) twice, i.e. in a loop.
More than one trunk or subscriber line can be guided through a ferrite
sleeve. You can guide as many lines through a ferrite sleeve as long as the
ferrite sleeve can still be closed properly. These means there can be no gap
between the two ferrite halves.
The ferrite sleeves should where possible be mounted in the cable duct. If
the number of lines makes this impossible, the ferrite can be attached direct-
ly at the output of the cable duct.
If there are insufficient ferrite sleeves supplied in the accessory pack for all trunk and
>
subscriber lines, additional ferrite sleeves must be ordered:
L30460-X1358-X-* (direct sales) / L30251-U600-A229 (export): Contains 5 fer-
rite sleeves C39022-Z7000-C6
L30460-X1359-X-* (direct sales) / L30251-U600-A230 (export): Contains 9 fer-
rite sleeves C39022-Z7000-C6
4-104
Trunk or subscriber line modules in "large" format:
Guide both standard cables from SUX8 and SUX9 (see Fig. 4-55 ) to the
MDFU through two ferrite sleeves (C39022-Z7000-C6) each. The ferrite
should be placed as far inside the housing as possible.
Trunk or subscriber line modules in "small" format:
Guide the trunk and subscriber lines of all ports connected on a board
through a ferrite sleeve (C39022-Z7000-C6) twice, i.e. in a loop.
More than one trunk or subscriber line can be guided through a ferrite
sleeve. You can guide as many lines through a ferrite sleeve as long as
the ferrite sleeve can still be closed properly. These means there can be
no gap between the two ferrite halves.
The ferrite sleeves should where possible be mounted in the cable duct.
If the number of lines makes this impossible, the ferrite can be attached
directly at the output of the cable duct.
Nur für den internen Gebrauch
Then
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation

Hide quick links: