HiPath 3000/5000 V9
Service documentation
A31003-H3590-S100-7-7620
Siemens Enterprise Communications
www.siemens-enterprise.com

Advertisement

loading

  Summary of Contents for Siemens HiPath 3000 Series

  • Page 1 Documentation HiPath 3000/5000 V9 Service documentation A31003-H3590-S100-7-7620 Siemens Enterprise Communications www.siemens-enterprise.com...
  • Page 2 Communications GmbH & Co. KG 06/2012 Hofmannstr. 51, D-80200 München Siemens Enterprise Communications GmbH & Co. KG is a Trademark Licensee of Siemens AG Reference No.: A31003-H3590-S100-7-7620 The information provided in this document contains merely general descriptions or characteristics of...
  • Page 3: Table Of Contents

    hp3hp5shTOC.fm Contents Nur für den internen Gebrauch Contents 1 Introduction and Important Notes ........1-1 1.1 About this Documentation .
  • Page 4 hp3hp5shTOC.fm Contents Nur für den internen Gebrauch 2.1.5.5 HiPath 3300 System Environment ....... . . 2-15 2.1.6 Central components of the HiPath 3000 system .
  • Page 5 hp3hp5shTOC.fm Contents Nur für den internen Gebrauch 2.5.4.2.6 VPN Networking with Data and Voice Connections....2-75 2.5.4.2.7 IP telephones/clients for ISDN and ITSP Connection in HiPath 3800 . . 2-77 2.5.5 Maximum Number of Devices for Special Cases .
  • Page 6 hp3hp5shTOC.fm Contents Nur für den internen Gebrauch 3.3.2 DIUN2 ............3-84 3.3.3 DIUT2 .
  • Page 7 hp3hp5shTOC.fm Contents Nur für den internen Gebrauch 3.3.47 4SLA (not for U.S.), 8SLA, 16SLA (Not for U.S.) ..... . 3-348 3.3.48 8SLAR .
  • Page 8 hp3hp5shTOC.fm Contents Nur für den internen Gebrauch 4.1.4.3.1 Introduction ..........4-24 4.1.4.3.2 Mounting a System Cabinet using Support and Angle Brackets.
  • Page 9 hp3hp5shTOC.fm Contents Nur für den internen Gebrauch 4.2.3.4 Removing the System Housing Cover ......4-92 4.2.3.5 Attaching the System to the Wall .
  • Page 10 hp3hp5shTOC.fm Contents Nur für den internen Gebrauch 5.2.5 Not for U.S.: Entering the System Number......5-17 5.2.6 Customer-Specific Programming .
  • Page 11 hp3hp5shTOC.fm Contents Nur für den internen Gebrauch 6.9.3.3 Other considerations ......... . 6-46 6.10 Perform HiPath 5000 Basic Configuration .
  • Page 12 hp3hp5shTOC.fm Contents Nur für den internen Gebrauch 9.1.3.3 Installation Options ..........9-14 9.1.3.4 Technical Specifications .
  • Page 13 hp3hp5shTOC.fm Contents Nur für den internen Gebrauch 10.1.5 OpenStage Accessories ......... 10-38 10.1.5.1 External Power Supply .
  • Page 14 hp3hp5shTOC.fm Contents Nur für den internen Gebrauch 10.5.2.3 Possible Configurations for the Key Modules ..... . 10-94 10.5.3 optiPoint 500 Adapters ......... . 10-95 10.5.3.1 optiPoint analog adapter .
  • Page 15 hp3hp5shTOC.fm Contents Nur für den internen Gebrauch 12 Service ............12-1 12.1 System Administration Options .
  • Page 16 hp3hp5shTOC.fm Contents Nur für den internen Gebrauch 12.3.2.1 Inserting and Removing HiPath 3000 Boards ..... . 12-22 12.3.2.2 Exchanging Workpoint Clients ....... . . 12-24 12.3.3 Relocate/Transfer Application Processor Software (APS) .
  • Page 17 hp3hp5shTOC.fm Contents Nur für den internen Gebrauch 12.4.16 HiPath 3000-Error mess. (Entries in the event log for HiPath 3000) ..12-61 12.4.17 HiPath 5000-Error mess. (Event Viewer Entries for HiPath 5000) ..12-88 12.5 Correcting Errors .
  • Page 18 hp3hp5shTOC.fm Contents Nur für den internen Gebrauch 13.6.1.1 Protocols Used..........13-14 13.6.2 Security/Firewall/Packet Filter .
  • Page 19 hp3hp5shTOC.fm Contents Nur für den internen Gebrauch 13.6.17 Quality of Service in HG 1500 ........13-49 13.7 IP Trunking .
  • Page 20 hp3hp5shTOC.fm Contents Nur für den internen Gebrauch F.2 Countries with Country Code “IM”......... F-3 Abbreviations .
  • Page 21: Introduction And Important Notes

    inform.fm Nur für den internen Gebrauch Introduction and Important Notes Introduction and Important Notes HiPath 3000/5000 V9 Service documentation: A31003-H3590-S100-7-7620, HZ700D.50.070, 06/2012 HiPath 3000/5000 is a high-performance, reliable communication platform for medium-sized enterprises. It offers the wide range of functionality of a traditional telephony system, coupled with modern UC communication solutions.
  • Page 22: About This Documentation

    inform.fm Introduction and Important Notes Nur für den internen Gebrauch About this Documentation About this Documentation This documentation describes the communication systems HiPath 3800, HiPath 3550, HiPath 3350, HiPath 3500 and HiPath 3300 and the Real-Time Service Manager HiPath 5000 RSM that are a part of the HiPath 3000 system family. HiPath 3000/5000 is also called “the communication system”...
  • Page 23: Hipath 3000/5000 V9 , Service Documentation

    inform.fm Introduction and Important Notes Nur für den internen Gebrauch About this Documentation HiPath 3000/5000 V9, Service Documentation ● This documentation describes the hardware, assembly and commissioning of the HiPath 3000/5000 and is intended for service technicians. HiPath 3000/5000 V9, Inventory Manager, Operating Instructions ●...
  • Page 24: Manual Structure

    inform.fm Introduction and Important Notes Nur für den internen Gebrauch About this Documentation 1.1.2 Manual Structure This documentation covers the following subjects: Chapter Description Chapter 1, “Introduction and Im- This chapter contains the basic information necessary for portant Notes” working with the product and with this service documenta- tion.
  • Page 25: Hipath 3000/5000 V9 , Service Documentation

    inform.fm Introduction and Important Notes Nur für den internen Gebrauch About this Documentation Chapter Description Appendix A, “System Program- These appendices contain lists with programming codes, IP ming Codes (Expert Mode protocols, port numbers. Codes)” Appendix B, “Codes for Activat- ing/Deactivating Features”...
  • Page 26: Notational Conventions

    inform.fm Introduction and Important Notes Nur für den internen Gebrauch About this Documentation 1.1.3 Notational Conventions The documentation for HiPath 3000/5000 uses various means for presenting different kinds of information. Purpose Style Example Body text that is of particular im- Bold Name must not be deleted.
  • Page 27: Safety Information And Warnings

    inform.fm Introduction and Important Notes Nur für den internen Gebrauch safety information and warnings safety information and warnings General conditions Work on communication systems and devices may only be carried out by qualified per- ● sons. For the purposes of safety information and warnings, qualified persons are persons who are authorized to place into operation, ground, and label systems, devices, and lines in accordance with applicable safety procedures and standards.
  • Page 28: Warning Sign: Danger

    inform.fm Introduction and Important Notes Nur für den internen Gebrauch safety information and warnings Symbols for specifying the source of danger more exactly The following symbols are not usually used in the manual. They explain symbols that may be depicted on the communication systems and equipment. Electricity Weight Heat...
  • Page 29: Warning Sign: Warning

    inform.fm Introduction and Important Notes Nur für den internen Gebrauch safety information and warnings 1.2.2 Warning Sign: WARNING WARNING Risk of electric shock through contact with live wires An electric shock can be life-threatening or lead to serious injuries such as burns. There are additional dangers even when working with low voltage and large cable cross-sections.
  • Page 30 inform.fm Introduction and Important Notes Nur für den internen Gebrauch safety information and warnings WARNING Disconnection from power circuit(s) A disconnect device can be a disconnecting switch (main switch), circuit breaker (fuse/cutout), or power plug that completely disconnects the telecommunication sys- tem and device from the power circuit.
  • Page 31: Warning Sign: Caution

    inform.fm Introduction and Important Notes Nur für den internen Gebrauch safety information and warnings 1.2.3 Warning Sign: CAUTION CAUTION Danger of injury When working on an open communication system or device, make sure that it ● is never left unattended. Risk of injury resulting from heavy items or loads.
  • Page 32: Safety Information For Australia (For Australia Only)

    inform.fm Introduction and Important Notes Nur für den internen Gebrauch safety information and warnings 1.2.4 Safety Information for Australia (for Australia only) Music on Hold and paging devices must be connected to the HiPath 3000 via an ACA ap- ● proved Line Isolation Unit.
  • Page 33: Hipath 3000/5000 V9 , Service Documentation

    inform.fm Introduction and Important Notes Nur für den internen Gebrauch safety information and warnings – Only use grounded soldering irons. Use only original accessories. Failure to observe these instructions may damage the ● equipment or even violate safety and EMC regulations. Before starting wall mounting, check that the wall has sufficient bearing strength.
  • Page 34: Emergencies

    inform.fm Introduction and Important Notes Nur für den internen Gebrauch Emergencies Emergencies Actions in emergencies Remain calm in the event of an accident. ● Disconnect the power before touching the victim. ● If you cannot disconnect the power immediately, use a non-conducting object, such as a ●...
  • Page 35: Correct Disposal And Recycling

    inform.fm Introduction and Important Notes Nur für den internen Gebrauch Correct Disposal and Recycling Correct Disposal and Recycling All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities. The correct disposal and separate collection of your old appliance will help prevent potential negative consequences for the environment and human health.
  • Page 36: Standards And Guidelines For Installation

    inform.fm Introduction and Important Notes Nur für den internen Gebrauch Standards and Guidelines for Installation Standards and Guidelines for Installation 1.6.1 Connection to the Power Circuit HiPath communication systems are approved for connection to TN-S power supply systems. They can also be connected to a TN-C-S power supply system in which the PEN conductor is divided into a ground wire and a neutral wire.
  • Page 37: Shielded Cables For Lan, Wan And Dmz Connections

    inform.fm Introduction and Important Notes Nur für den internen Gebrauch Standards and Guidelines for Installation 1.6.3 Shielded Cables for LAN, WAN and DMZ Connections Compliance with CE requirements on electromagnetic capability of communication systems and their LAN, WAN and DMZ connections requires the following: Communication systems may only be operated using shielded connection cables.
  • Page 38: Lightning Protection

    inform.fm Introduction and Important Notes Nur für den internen Gebrauch Standards and Guidelines for Installation 1.6.4 Lightning Protection NOTE > Lightning protection for the boards Analog and digital subscriber lines are protected on the boards, for up to 2 kV longi- tudinal voltage and 1 kV transverse voltage, against the high-energy surge voltage with a pulse shape of 10/700 µs and 1.2/50 µs that can be induced by lightning.
  • Page 39: Privacy And Data Security

    Employees of Siemens Enterprise Communications GmbH & Co. KG are bound to safeguard trade secrets and personal data under the terms of the company’s work rules.
  • Page 40: Further Information

    Administrator documentation Portuguese ● Service documentation Spanish ● Sales documentation ● Expert Wiki German http://wiki.siemens-enterprise.com Information about communication English systems, telephones and Unified Communications OpenScape Interactive Request German https://osiris.siemens-enterprise.com/ and Information System OSIRIS Knowledge base with questions and answers on products and solutions...
  • Page 41: System Data

    sysdat.fm Nur für den internen Gebrauch System Data System Data Chapter contents This chapter covers the following topics: Topic HiPath 3000, page 2-3 Electrical environment, page 2-3 ● Lightning Protection, page 2-3 ● Individual HiPath 3000 System Models, page 2-4 ●...
  • Page 42 sysdat.fm System Data Nur für den internen Gebrauch Topic Gateway channels (DSP channels), page 2-47 ● Connections to ITSP, page 2-49 ● MOH Channels (G.711, G.723, G.729), page 2-50 ● IP Networking Channels (PBX Networking Channels), page 2-50 ● Bandwidth Control for IP Networking Channels (PBX Networking Channels), page 2-50 ●...
  • Page 43: Hipath 3000

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 HiPath 3000 2.1.1 Electrical environment HiPath 3000 is intended for use in dwellings, businesses, and industry. When the system is op- erated in an industrial environment, additional measures may be necessary for ensuring immu- nity from electromagnetic radiation (refer to Section 2.11).
  • Page 44: Individual Hipath 3000 System Models

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.3 Individual HiPath 3000 System Models This service manual contains information on all HiPath 3000 systems. Information on marketing individual models in different countries can be obtained at the responsible locations. System for standalone installation and for installation in 19-inch cabinets: ●...
  • Page 45: Design And Dimensions Of The Hipath 3000 Systems

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.4 Design and Dimensions of the HiPath 3000 Systems 2.1.4.1 Design and Dimensions of HiPath 3800 Two configurations Depending on the requirements, HiPath 3800 can be used as: a single-cabinet system (basic cabinet BC) ●...
  • Page 46 sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 Dimensions approx. 440 mm approx. 430 mm Figure 2-1 HiPath 3800 Dimensions A31003-H3590-S100-7-7620, 06/2012 HiPath 3000/5000 V9, Service documentation...
  • Page 47: Design And Dimensions Of Hipath 3550

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.4.2 Design and Dimensions of HiPath 3550 Design The housing intended for wall mounting (Figure 2-2) HiPath 3550 contains one shelf with six slot levels. The slot levels (shown in Figure 4-58), numbered in ascending order from the at- tachment side, have the following assignments: Slot levels 1-3: peripheral boards (two slots per level).
  • Page 48: Design And Dimensions Of Hipath 3350

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.4.3 Design and Dimensions of HiPath 3350 Except for the CBCC board, the Octopus F100 communication system is identical in > structure to HiPath 3350. The part number of this CBCC is: S30810-K2935-T401. Design The housing intended for wall mounting (Figure 2-3)HiPath 3350 contains one shelf with three slot levels.
  • Page 49: Design And Dimensions Of Hipath 3500

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.4.4 Design and Dimensions of HiPath 3500 Design The housing intended for use with 19-inch cabinets (Figure 2-4) HiPath 3500 contains four slot levels with the following assignments (represented in Figure 4-66): Slot levels 1-3: slide-in shelves for peripheral boards (2 boards can be plugged in on each ●...
  • Page 50: Design And Dimensions Of Hipath 3300

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.4.5 Design and Dimensions of HiPath 3300 Design The housing intended for use with 19-inch cabinets (Figure 2-5)HiPath 3300 contains three slots with the following assignments (represented in Figure 4-67): Slot level 1: slide-in shelves for two peripheral boards ●...
  • Page 51: System Environment Of The Hipath 3000 Systems

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.5 System Environment of the HiPath 3000 Systems 2.1.5.1 HiPath 3800 System Environment Table 2-1 Boards for HiPath 3800 HiPath 3800 Subscriber Line Modules Central Board Trunk Boards Options IVMN8 CBSAP DIU2U IVMNL...
  • Page 52: Hipath 3550 System Environment

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.5.2 HiPath 3550 System Environment Table 2-2 Boards for HiPath 3550 HiPath 3550 Subscriber Line Modules Central Board Trunk Boards Options HXGS3 CBCC HXGS3 IVMS8 STLS2 SLA8N STLS4 SLA16N STLSX2 SLA24N IMODN STLSX4...
  • Page 53: Hipath 3350 System Environment

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.5.3 HiPath 3350 System Environment Table 2-3 Boards for HiPath 3350 HiPath 3350 Subscriber Line Modules Central Board Trunk Boards Options HXGS3 CBCC HXGS3 IVMP8 STLS2 IVMS8 STLS4 SLU8 STLSX2 STLS2 IMODN STLSX4...
  • Page 54: Hipath 3500 System Environment

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.5.4 HiPath 3500 System Environment Table 2-4 Boards for HiPath 3500 HiPath 3500 Subscriber Line Modules Central Board Trunk Boards Options HXGR3 CBRC HXGR3 IVMS8R STLS4R SLU8R STLSX4R STLS4R CUCR TCASR-2 STLSX4R IMODN...
  • Page 55: Hipath 3300 System Environment

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.5.5 HiPath 3300 System Environment Table 2-5 Boards for HiPath 3300 HiPath 3300 Subscriber Line Modules Central Board Trunk Boards Options HXGR3 CBRC HXGR3 IVMP8R STLS4R IVMS8R STLSX4R SLU8R CUPR TLA4R STLS4R IMODN...
  • Page 56: Central Components Of The Hipath 3000 System

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.6 Central components of the HiPath 3000 system 2.1.6.1 Central components, HiPath 3800 CBSAP The CBSAP board performs all central control and switching functions for HiPath 3800. The following subboards can be used depending on the application: CMS clock module (optional) ●...
  • Page 57: Central Components, Hipath 3550

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.6.2 Central components, HiPath 3550 CBCC The CBCC board performs all central control and switching functions for HiPath 3550. The following subboards (some of which are optional) can be used depending on the applica- tion: CMS clock module small [optional] ●...
  • Page 58: Central Components, Hipath 3350

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.6.3 Central components, HiPath 3350 CBCC The CBCC board performs all central control and switching functions for HiPath 3350. The following subboards (some of which are optional) can be used depending on the applica- tion: CMS clock module small [optional] ●...
  • Page 59: Central Components, Hipath 3500

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.6.4 Central components, HiPath 3500 CBRC The CBRC board performs all central control and switching functions for HiPath 3500. The following subboards (some of which are optional) can be used depending on the applica- tion: CMS clock module small [optional] ●...
  • Page 60: Central Components, Hipath 3300

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.6.5 Central components, HiPath 3300 CBRC The CBRC board performs all central control and switching functions for HiPath 3300. The following subboards (some of which are optional) can be used depending on the applica- tion: CMS clock module small [optional] ●...
  • Page 61: Peripheral Components Of The Hipath 3000 Systems

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.7 Peripheral components of the HiPath 3000 systems 2.1.7.1 Peripheral components, HiPath 3800 Subscriber Line Modules Table 2-6 Subscriber Line Modules for HiPath 3800 Board Capacity Coun- Type/Description Name IVMN8 x These boards are for the integrated voicemail func- tions of HiPath Xpressions Compact.
  • Page 62 sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 Table 2-6 Subscriber Line Modules for HiPath 3800 Board Capacity Coun- Type/Description Name SLMO2 24 48 x The optiPoint and OpenStage telephones are connect- ed via this board. The SLMO board comes in 8- and SLMO8 24-port versions.
  • Page 63 sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 Table 2-7 Trunk Boards for HiPath 3800 Board Capacity Coun- Type/Description Name DIUN2 60 60 x Basic rate interface (BRI) board; can also be used for tie trunk traffic. In HiPath 3000/HiPath 5000 V5.0 and later, the B channels in the DIUN2 board must be licensed.
  • Page 64 sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 Table 2-7 Trunk Boards for HiPath 3800 Board Capacity Coun- Type/Description Name TMC16 x Analog trunk board (ground/loop start) TM2LP x Board with 8 ports to connect LS trunk connections and enables CAS trunk connections TMCAS-2: For selected countries only DIUT2: Up to 3 DIUT2 and/or DIUN2 per system.
  • Page 65 sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 Table 2-8 Tie Trunk Traffic Boards for HiPath 3800 Board Capacity Coun- Type/Description Name TMEW2 x Board for providing four two-way analog tie trunk cir- cuits with E&M signaling. Note on compatibility in E&M networks: TMEW2 does not support E&M interface types 1, 1B, 2, 3, and 5 on the TIEL board.
  • Page 66 sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 Table 2-9 Optional Boards for HiPath 3800 Board Capacity Coun- Type/Description Name REALS Relay con- x The REALS board is located on the basic cabinet’s back- nections plane. It can be used for connecting relays (door opener) and trunk switching (ALUM).
  • Page 67: Peripheral Components, Hipath 3550

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.7.2 Peripheral components, HiPath 3550 Subscriber Line Modules Table 2-10 Subscriber Line Modules for HiPath 3550 Board Capacity Coun- Type/Description Name 4SLA - Board for connecting analog stations (a/b, T/R) 8SLA x Board for connecting analog stations (a/b, T/R) 16SLA...
  • Page 68 sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 Trunk Boards Table 2-11 Trunk Boards for HiPath 3550 Board Capacity Coun- Type/Description Name TCAS-2 2 60 - Board for supporting country-specific CAS (Channel Associated Signaling) protocols - Trunk board for analog lines TLA4 - Trunk board for analog lines TLANI2...
  • Page 69 sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 The maximum number is calculated on the basis of the system-specific capacity limits, See Section 2.3, “System-Specific Capacity Limits for HiPath 3000, HiPath 5000”. Boards for Tie Trunk Traffic Table 2-12 Tie Trunk Traffic Boards for HiPath 3550 Board Capacity...
  • Page 70 sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 Options Table 2-13 Optional Boards for HiPath 3550 Board Capacity Coun- Type/Description Name ALUM4 Trunk failure x Trunk failure transfer lets you transfer loop start transfers trunks directly to internal analog stations in the event of a power failure (note the signaling method used).
  • Page 71: Peripheral Components, Hipath 3350

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.7.3 Peripheral components, HiPath 3350 Subscriber Line Modules Table 2-14 Subscriber Line Modules for HiPath 3350 Board Capacity Coun- Type/Description Name 4SLA - Board for connecting analog stations (a/b, T/R) 8SLA x Board for connecting analog stations (a/b, T/R) 16SLA...
  • Page 72 sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 Trunk Boards Table 2-15 Trunk Boards for HiPath 3350 Board Capacity Coun- Type/Description Name TLA2 - Trunk board for analog lines TLA4 - Trunk board for analog lines TLA8 - Trunk board for analog lines TLANI2 x Trunk board for analog lines including ALUM TLANI4...
  • Page 73 sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 Boards for Tie Trunk Traffic Table 2-16 Tie Trunk Traffic Boards for HiPath 3350 Board Capacity Coun- Type/Description Name HXGS3 x HG 1500 board for connecting the HiPath 3350 system di- rectly to a local data network (Ethernet).
  • Page 74 sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 Table 2-17 Optional Boards for HiPath 3350 Board Capacity Coun- Type/Description Name GEE50 Number of call - This optional board records the country-specific call charge receiv- charge pulses (50 Hz) from the trunk. V24/1 Interfaces x Serial V.24 interface for connecting a PC, printer, or...
  • Page 75: Peripheral Components, Hipath 3500

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 2.1.7.4 Peripheral components, HiPath 3500 Subscriber Line Modules Table 2-18 Subscriber Line Modules for HiPath 3500 Board Capacity Coun- Type/Description Name 8SLAR x Board for connecting analog stations (a/b, T/R) HXGR3 x HG 1500 board for the direct connection of IP workpoint cli- ents.
  • Page 76 sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 Trunk Boards Table 2-19 Trunk Boards for HiPath 3500 Board Capacity Coun- Type/Description Name TCASR-2 2 60 - Board for supporting country-specific CAS (Channel Associated Signaling) protocols STLS4R x Board for ISDN basic access. Permits configuration of ISDN trunks, tie trunks, and subscribers (no feeding) on the same board.
  • Page 77 sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 Boards for Tie Trunk Traffic Table 2-20 Tie Trunk Traffic Boards for HiPath 3500 Board Capacity Coun- Type/Description Name HXGR3 x HG 1500 board for connecting the HiPath 3500 system di- rectly to a local data network (Ethernet).
  • Page 78: Peripheral Components, Hipath 3300

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 Table 2-21 Optional Boards for HiPath 3500 Board Capacity Coun- Type/Description Name STRBR Sensors x Control relay module; provides 4 relays and 4 sensors for controlling external devices or detecting external Relay control events.
  • Page 79 sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 Table 2-22 Subscriber Line Modules for HiPath 3300 Board Capacity Coun- Type/Description Name STLS4R x Board for ISDN basic rate access. Configuration of ISDN trunks, tie trunks, and stations (no feeding) on the same board is possible.
  • Page 80 sysdat.fm System Data Nur für den internen Gebrauch HiPath 3000 Boards for Tie Trunk Traffic Table 2-24 Tie Trunk Traffic Boards for HiPath 3300 Board Capacity Coun- Type/Description Name HXGR3 x HG 1500 board for connecting the HiPath 3300 system di- rectly to a local data network (Ethernet).
  • Page 81: Hipath 5000

    sysdat.fm System Data Nur für den internen Gebrauch HiPath 5000 HiPath 5000 HiPath 5000 Real-Time Services Manager RSM is operated as a central administration unit in an IP network of HiPath 3000 systems. By creating a “Single System Image”, all relevant nodes can be centrally administered.
  • Page 82 sysdat.fm System Data Nur für den internen Gebrauch HiPath 5000 Central resourcing of applications Central administration unit with: (possibly installed on a separate Feature Server ● PC), such as: Presence Manager ● OpenScape Xpressions ● Software Update Manager ● OpenScape Contact Center ●...
  • Page 83: System-Specific Capacity Limits For Hipath 3000, Hipath 5000

    sysdat.fm System Data Nur für den internen Gebrauch System-Specific Capacity Limits for HiPath 3000, HiPath 5000 System-Specific Capacity Limits for HiPath 3000, HiPath 5000 The maximum capacity limits are calculated based on the following assumptions: HiPath 3800: two board slots are reserved for trunks. ●...
  • Page 84 As a guide, configurations that include UCD/ACD, more than one SLC16N, groups with more than 10 stations or OpenScape Office connections should always be inspected using the project planning tool (https:/ /enterprise-businessarea.siemens-enterprise.com/productinfo/document/9fTFkWdA76U_/Hi- Path%203000%20V8%20Planungsanleitung%20Performance%20Calculation%20Tool.xls). Only configurations that do not exceed this limit will be supported.
  • Page 85: Static Configuration Rules

    sysdat.fm System Data Nur für den internen Gebrauch Static Configuration Rules Static Configuration Rules 2.4.1 Resources and Capacity Limits For information on the configuration of HG 1500 boards, refer to the HG 1500 Ad- > ministration Manual. With HiPath 3000/5000, HG 1500 provides the resources listed in Table 2-27 via the HG 1500 boards defined as media gateways (= gateway HG 1500).
  • Page 86 sysdat.fm System Data Nur für den internen Gebrauch Static Configuration Rules Table 2-27 Technical Specifications (Resources) of the HG 1500 Boards Defined as Me- dia Gateways Resource HXGS3 STMI2 HXGR3 with- with 1 PDM1 PDM1 MOH Channels (G.711, G.723, G.729) The number of MoH channels used depends on the configu- ration (HiPath 3000/5000 Manager E).
  • Page 87: Gateway Channels (Dsp Channels)

    sysdat.fm System Data Nur für den internen Gebrauch Static Configuration Rules 2.4.2 Gateway channels (DSP channels) Connections from IP workpoint clients/lines to TDM workpoint clients/lines Gateway connections are required for connections from IP to TDM workpoint clients and lines. A gateway channel is required on the HG 1500 board for each gateway connection. TDM workpoint clients/lines are: stations (optiPoint 500) ●...
  • Page 88 sysdat.fm System Data Nur für den internen Gebrauch Static Configuration Rules Table 2-29 Number of Required Gateway Channels (HG 1500 Boards) IP workpoint clients in the system Required number of gateway channels 0 – 3 4 – 12 13 – 16 17 –...
  • Page 89: Connections To Itsp

    sysdat.fm System Data Nur für den internen Gebrauch Static Configuration Rules 2.4.3 Connections to ITSP Overview HG 1500 supports connections to the Internet telephony service provider (ITSP) and thus the use of Internet telephony in HiPath 3000/5000 V6.0 SMR-09 or later, particularly DID-enabled DSL connections with phone number range.
  • Page 90: Moh Channels (G.711, G.723, G.729)

    sysdat.fm System Data Nur für den internen Gebrauch Static Configuration Rules 2.4.4 MOH Channels (G.711, G.723, G.729) A DSP channel is reserved on an HG 1500 board for each codec used for MOH. Up to five co- decs can be configured for MOH for every HG 1500 board. Examples: Only the codec G.711 is used for MOH: –>...
  • Page 91: Dmc (Direct Media Connection) Channels

    sysdat.fm System Data Nur für den internen Gebrauch Static Configuration Rules 2.4.7 DMC (Direct Media Connection) Channels When the DMC interworking feature is active in an IP network between HiPath 3000 and HiPath 4000, gateway connections are set up over DMC channels. From the user’s perspective, a DMC channel is a gateway channel that provides a gateway connection between HiPath 3000 and HiPath 4000.
  • Page 92: Fax/Modem Channels

    sysdat.fm System Data Nur für den internen Gebrauch Static Configuration Rules 2.4.9 Fax/Modem Channels It is possible to transmit faxes with Internet telephony both via G.711 gateway channels and, in HiPath 3000/5000 V7 R4 or later, via T.38 channels. Although T.38 offers the more reliable method of fax transmission, it can only be used to a max- imum of 14 Kbps.
  • Page 93: Dynamic Configuration Rules

    sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules Dynamic Configuration Rules This section describes the underlying theoretical principles for the thumb rule by which the con- trol load, and thus the dynamic performance characteristics, of HiPath 3000/5000 V9 systems can be determined.
  • Page 94 Nur für den internen Gebrauch Dynamic Configuration Rules Project Planning Tools for HiPath Systems An electronic version of the thumb rule in which all the following calculations are implemented will also be made available under the following link: https://enterprise-businessarea.siemens-enterprise.com/productinfo/document/ 9fTFkWdA76U_/Hi- Path%203000%20V8%20Planungsanleitung%20Performance%20Calculation%20Tool.xls A31003-H3590-S100-7-7620, 06/2012 2-54...
  • Page 95: Planning Load For Hipath Systems

    sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules 2.5.2.2 Planning Load for HiPath Systems This section describes a dimensioning method for the various systems. In order to provide for sufficient reserves to handle load fluctuations during operations, a so-called planning load is defined the systems.
  • Page 96: Maximum Permissible Values For Hipath 3000/5000V9

    sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules 2.5.2.3 Maximum Permissible Values for HiPath 3000/5000V9 For version V9, the following maximum permissible point totals are used as a basis for the thumb rule (Norm BHCA): Table 2-34 HiPath 3000/5000 V9 Expansion Levels and their Maximum Points HiPath 3000 Maximum Points...
  • Page 97: Additional Parameters

    sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules 2.5.2.4 Additional Parameters In order to calculate the number of points for a specific system, several additional parameters are usually required. These parameters are described below. Factor F (subscriber traffic factor): ●...
  • Page 98: Current Thumb Rule Values

    sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules Factor g for mobility within a CMI node: ● This thumb rule formula is based on the assumption of the mobility level of mobile subscrib- ers. The factor g determines the probability that a station is not located at its home board when visiting the radio area of it home system.
  • Page 99 sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules Telephones Table 2-35 Points for Devices System Interface Meaning Weight Analog Number of devices connected via T/R wires. 3.3 · F devices Number of devices connected via U (for example, op- 7.7 ·...
  • Page 100 sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules Special Devices Table 2-37 Points for Special Devices System Interface Meaning Weight UCD Agent Number of active UCD agents controlled by the OSCC 59 · C (HPCC, OSCC) application. ACD Agent Number of active ACD agents, where the display of each 179 / T +...
  • Page 101 sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules Additional Overhead for Features The additional overhead values listed below are based on the assumption that the correspond- ing basic overhead for each terminal device involved has already been recorded in Table 2-35. Table 2-39 Additional Overhead for Controlling Process Flows at Devices via CTI Applica- tions...
  • Page 102: Thumb Rule For Hg 1500 V3.0

    sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules 2.5.3 Thumb Rule for HG 1500 V3.0 2.5.3.1 Procedural Principles The thumb rule presented below for calculating the dynamic load for the HG 1500 board is based on the principle of considering every functionality (HFA phone, IP trunking, gateway channels, VPN tunnel, etc.) in terms of its CPU load.
  • Page 103 sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules Table 2-43 Points for Signaling Meaning Weight System System PBX networking Number of digital B channels (networking trunk) to other nodes 3.2 · F channel without or to Xpressions via IP (GK security is deactivated). H.235 PBX networking Number of digital B channels (networking trunk) to other nodes...
  • Page 104 sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules Table 2-44 Points for Gateway Channels (When Using G.711 or G.729) Meaning Weight System System Number of gateway channels (DSP ↔ LAN) if only the Gateway channels with VPN and AES voice codec G.723 and VPN with AES encryption are used.
  • Page 105 sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules Data (LAN) The following table indicates the HG 1500 data routing load (LAN1 ↔ LAN2), e.g., for a DSL connection to the Internet or a data connection for two locations via VPN.
  • Page 106 sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules Table 2-47 Points for PPP Channels Meaning Weight System System Voice channels Number of voice channels with G.723 and a packet assembly of (G.723 – 1) 1 (20ms) that are routed with PPP via ISDN. Voice channels Number of voice channels with G.723 and a packet assembly of (G.723 –...
  • Page 107: Example For Using The Thumb Rule

    sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules 2.5.4 Example for Using the Thumb Rule Using a standard configuration, the following example illustrates a calculation based on the thumb rule. 2.5.4.1 HiPath 3000/5000 V9 Configuration Number Type Anate (analog telephones, terminal devices) Digital terminal devices Digital terminal devices with CTI-controlled functions...
  • Page 108: Hg 1500 Configurations

    sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules 2.5.4.2 HG 1500 Configurations 2.5.4.2.1 IP Trunking with TDM Terminal Points Only A HiPath 3800 system is networked with another system via an IP trunking link with 32 B chan- nels.
  • Page 109 sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules The codec G.711 with a sample rate of 20 ms (without encryption) is required both for the IP trunking link and for the HFA terminal points. This requires an STMI2 module (2 DSPs on board = 32 voice channels are supported).
  • Page 110: Ip Trunking Via Lan And Wan (Isdn/Ppp)

    sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules 2.5.4.2.3 IP Trunking via LAN and WAN (ISDN/PPP) A HiPath 3800 system (head office) is connected to a second system (branch office 1) via an ISDN connection with 2 PPP channels (S ), and to a third system (branch office 2) via a direct LAN connection.
  • Page 111: Ip Trunking With Vpn (Voice Only)

    sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules 6 voice channels over PPP must be calculated for branch office 1. The points for G.729 with a packet assembly of 3 (60ms) must be used. 8 gateway channels via LAN 1 must be calculated for branch office 2.
  • Page 112 sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules Branch Office 1 ISDN HiPath 35x0 4 Voice PBX/Networking Channels AES Encryption Codec G.711 (20ms) LAN 2 ISDN LAN 1 Head Office 8 Gateway Channels 8 Voice PBX/Networking Intranet HiPath 3800 Channels AES Encryption...
  • Page 113: Standalone System With Home Offices Connected Via Vpn

    sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules Calculation for each individual branch office (HiPath 3500/3550): 4 gateway channels via LAN2 with AES encryption, and 8 gateway channels from HFA tele- phones to the local ISDN CO (via LAN1) must be calculated. The signaling load must also be taken into account.
  • Page 114 sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules When calculating the data traffic load, the upstream and downstream packet rates must be cal- culated from the average packet length. 512 · 1000 / 8 byte/s 512 · 1000 / 8 byte/s = 128 packets/s = 128 packets/s 500 bytes/packet...
  • Page 115: Vpn Networking With Data And Voice Connections

    sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules 2.5.4.2.6 VPN Networking with Data and Voice Connections A 1000 Kbps duplex data connection between 2 HiPath 3800 systems should be configured via a 2 Mbps SDSL interface. The average packet size should be 500 bytes. The SDSL connection should also be used for trunk connections with G.729 and a sample rate of 20ms.
  • Page 116 sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules Table 2-56 Performance Calculation (2) Function Formula Points Signaling: IP phones (without H.235) · Gateway channels: G.729 with VPN and AES · Data (LAN): VPN and AES with 500 bytes upstream 1.19 ·...
  • Page 117: Ip Telephones/Clients For Isdn And Itsp Connection In Hipath 3800

    sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules 2.5.4.2.7 IP telephones/clients for ISDN and ITSP Connection in HiPath 3800 Conditions The following conditions apply to this scenario: 100 IP telephones/clients (without H.235) are connected to HiPath 3800 . ●...
  • Page 118 sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules Calculation Table 2-58 Resource requirement for ISDN and ITSP connection for HiPath 3800 Function Formula Points Signaling without H.235 security (inde- 100 x IP telephones/clients, 100 x 0.68 pendent of the setting “Enhanced B 8 calls per hour Channels”) Payload (setting “Enhanced B Chan-...
  • Page 119: Maximum Number Of Devices For Special Cases

    sysdat.fm System Data Nur für den internen Gebrauch Dynamic Configuration Rules 2.5.5 Maximum Number of Devices for Special Cases This thumb rule can be used to calculate the maximum number of terminal devices for specific configurations. The formula for the calculation is as follows: Max No.
  • Page 120: Technical Specifications For Hipath 3000

    sysdat.fm System Data Nur für den internen Gebrauch Technical Specifications for HiPath 3000 Technical Specifications for HiPath 3000 Table 2-59 Technical Specifications Maximum System HiPath 3800 HiPath HiPath HiPath HiPath Values 3550 3350 3500 3300 Ringer Equivalence 2.6 A / 115 - 1.3 A / 115 - 2.6 A / 115 - 1.3 A / 115 -...
  • Page 121: Interface-To-Interface Ranges

    sysdat.fm System Data Nur für den internen Gebrauch Interface-to-Interface Ranges Interface-to-Interface Ranges Telephone interface-to-interface ranges Table 2-60 Telephone Interface-to-Interface Ranges (with J-Y (ST) 2x2x0.6, 0.6 mm di- ameter) Telephone Interfaces Range in m Loop resistance in ohms ISDN-S point-to-point < 600 ISDN S extended bus connection <...
  • Page 122: Country-Specific Ring Frequencies For Analog Subscriber Line Modules

    sysdat.fm System Data Nur für den internen Gebrauch Country-Specific Ring Frequencies for Analog Subscriber Line Modules Country-Specific Ring Frequencies for Analog Subscriber Line Modules The following table contains the ring frequency settings necessary for the implementing analog subscriber line modules in the various countries listed. Table 2-62 Country-Specific Ring Frequencies for Analog Subscriber Line Modules Country...
  • Page 123 sysdat.fm System Data Nur für den internen Gebrauch Country-Specific Ring Frequencies for Analog Subscriber Line Modules Table 2-62 Country-Specific Ring Frequencies for Analog Subscriber Line Modules Country Abbreviation Ring frequency (Hz) Luxembourg Malaysia Morocco Mexico The Netherlands Nigeria Oman Austria Pakistan The Philippines Poland...
  • Page 124: Numbering Plan

    sysdat.fm System Data Nur für den internen Gebrauch Numbering plan Numbering plan 2.9.1 Default Numbering for HiPath 3000/5000 HiPath 3000/5000 provides one default numbering plan for users. Table 2-63 Default numbers for HiPath 3000/5000 Type of numbering Default station numbers HiPath 3800 HiPath 3550 HiPath 3350 HiPath 3500...
  • Page 125: Internet Telephony Phone Numbers

    sysdat.fm System Data Nur für den internen Gebrauch Numbering plan 2.9.2 Internet telephony phone numbers HiPath 3000 supports connection to the Internet telephony service provider (ITSP) and, there- fore, the use of Internet telephony. For Internet telephony subscriber lines, each call number must be individually registered at the ITSP.
  • Page 126: Technical Specifications And Compliance To Hipath 3000

    sysdat.fm System Data Nur für den internen Gebrauch Technical Specifications and Compliance to HiPath 3000 2.10 Technical Specifications and Compliance to HiPath 3000 2.10.1 CE Compliance (not for U.S.) The systems conform to the following guidelines and standards: Guideline Standard R&TTE Directive 99/5/EEC EN 60950-1: 2001 (Safety) ●...
  • Page 127: Fcc Compliance

    2.10.2.1.1 FCC Rules, Part 15 Each Siemens Enterprise Communications GmbH & Co. KG system discussed in this section, except HiPath 3350, has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial envi- ronment.
  • Page 128 Nonlive voice equipment, such as, music-on-hold devices and recorded announcements for systems must be approved by Siemens Enterprise Communications GmbH & Co. KG and reg- istered in accordance with the rules and regulations of Subpart C of the FCC Rules, Part 68;...
  • Page 129 Nur für den internen Gebrauch Technical Specifications and Compliance to HiPath 3000 For the hearing impaired, all Siemens Enterprise Communications GmbH & Co. KG digital de- vices manufactured after August 16, 1989, are hearing-aid-compatible and comply with FCC Rules, Part 68, Section 68.316.
  • Page 130: Industry Canada Compliance

    Equal access is also obtained by dialing the 800/888 or 950 number of the carrier of choice. Each Siemens Enterprise Communications GmbH & Co. KG system discussed in this section is capable of providing user access to interstate providers of operator services through the use of equal access codes.
  • Page 131: Safety International

    sysdat.fm System Data Nur für den internen Gebrauch Technical Specifications and Compliance to HiPath 3000 Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunc- tions, may give the telecommunications company cause to request the user to disconnect the equipment.
  • Page 132: Environmental Conditions

    sysdat.fm System Data Nur für den internen Gebrauch Environmental Conditions 2.11 Environmental Conditions 2.11.1 Electrical Operating Conditions Operating limits ● Room temperature: + 5 ...+ 40 °C (41 ... 104 °F) Absolute humidity: 2 - 25 g H Relative humidity: 5 - 80% System ventilation is by convection only.
  • Page 133: Boards For Hipath 3000

    boards.fm Nur für den internen Gebrauch Boards for HiPath 3000 Boards for HiPath 3000 Chapter contents This chapter covers the following topics: Topic Section 3.1, “Functional and model overview of the boards” Section 3.2, “Central Board” Section 3.3, “Peripheral boards” Section 3.4, “Options”...
  • Page 134 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch NOTE (for Brazil only) > Danger of damage to property due to surge voltage: For protection against overvolt- age due to lightning, the use of the lightning protection strip with part number C39334-Z7052-C33 is absolutely mandatory.
  • Page 135: Functional And Model Overview Of The Boards

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Functional and model overview of the boards Functional and model overview of the boards Functional overview of all boards used Table 3-1 HiPath 3000 - Functional Overview of All Boards Used Board Part number Model...
  • Page 136 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Functional and model overview of the boards Table 3-1 HiPath 3000 - Functional Overview of All Boards Used Board Part number Model Peripheral boards Note: The HiPath 3550, HiPath 3350, HiPath 3500 and HiPath 3300 peripheral boards must be firmly inserted into their slots;...
  • Page 137 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Functional and model overview of the boards Table 3-1 HiPath 3000 - Functional Overview of All Boards Used Board Part number Model SLMAE S30810-Q2225-X200 HiPath 3800 SLMAE8 S30810-Q2225-X100 HiPath 3800 SLMAV8 S30810-Q2227-X100 HiPath 3800...
  • Page 138 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Functional and model overview of the boards Table 3-1 HiPath 3000 - Functional Overview of All Boards Used Board Part number Model TMANI-BRA S30810-Q2327-X82 HiPath 3800 TMC16 S30810-Q2485-X HiPath 3800(for selected countries only) TMCAS S30810-Q2938-X HiPath 3550(for selected countries only)
  • Page 139 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Functional and model overview of the boards Table 3-1 HiPath 3000 - Functional Overview of All Boards Used Board Part number Model Options ALUM4 S30817-Q935-A HiPath 3550/HiPath 3350 ANI4 S30807-Q6917-Axxx HiPath 3550/HiPath 3350 (for selected countries only) ANI4R...
  • Page 140 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Functional and model overview of the boards Table 3-1 HiPath 3000 - Functional Overview of All Boards Used Board Part number Model V24/1 S30807-Q6916-X100 HiPath 3550/HiPath 3350 (not for U.S.) A31003-H3590-S100-7-7620, 06/2012 HiPath 3000/5000 V9, Service documentation...
  • Page 141 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Functional and model overview of the boards Overview of all board models used Table 3-2 HiPath 3000 - Overview of All Boards Models Used Board Part number Function HiPath 3800 AMOM S30807-K5480-Xxxx Opto-electronic converter...
  • Page 142 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Functional and model overview of the boards Table 3-2 HiPath 3000 - Overview of All Boards Models Used Board Part number Function STMD3 S30810-Q2217-X10 Peripheral board STMI2 S30810-Q2316-X100 Peripheral board TM2LP S30810-Q2159-Xxxx Peripheral board...
  • Page 143 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Functional and model overview of the boards Table 3-2 HiPath 3000 - Overview of All Boards Models Used Board Part number Function HiPath 3550 Note: The HiPath 3550, HiPath 3350, HiPath 3500 and HiPath 3300 peripheral boards must be firmly inserted into their slots;...
  • Page 144 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Functional and model overview of the boards Table 3-2 HiPath 3000 - Overview of All Boards Models Used Board Part number Function SLMO24 S30810-Q2901-X Peripheral board SLU8 S30817-Q922-A301 Peripheral board STBG4 S30817-Q934-A Option (France only)
  • Page 145 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Functional and model overview of the boards Table 3-2 HiPath 3000 - Overview of All Boards Models Used Board Part number Function HiPath 3350 Note: The HiPath 3550, HiPath 3350, HiPath 3500 and HiPath 3300 peripheral boards must be firmly inserted into their slots;...
  • Page 146 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Functional and model overview of the boards Table 3-2 HiPath 3000 - Overview of All Boards Models Used Board Part number Function STLS2 S30817-Q924-B313 Peripheral board (not for U.S.) STLS4 S30817-Q924-A313 Peripheral board STLSX2...
  • Page 147 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Functional and model overview of the boards Table 3-2 HiPath 3000 - Overview of All Boards Models Used Board Part number Function HiPath 3500 Note: The HiPath 3550, HiPath 3350, HiPath 3500 and HiPath 3300 peripheral boards must be firmly inserted into their slots;...
  • Page 148 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Functional and model overview of the boards Table 3-2 HiPath 3000 - Overview of All Boards Models Used Board Part number Function HiPath 3300 Note: The HiPath 3550, HiPath 3350, HiPath 3500 and HiPath 3300 peripheral boards must be firmly inserted into their slots;...
  • Page 149: Central Board

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Central Board CAUTION The system must be disconnected from the power source before removing or insert- ing any boards in HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300, and be- fore removing or inserting the central boards in HiPath 3800.
  • Page 150 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Subboards The following subboards can be used depending on the application: Clock module (optional) ● MMC multimedia card ● IMODN integrated modem card new (optional) ● Music on hold (optional): ●...
  • Page 151 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Two digital S interfaces (CO (default) or station) ● Backplane (CUC or CUP) connection via slots 1 (X11), 2 (X5) and 3 (X6) ● Music on Hold: MPPI, MUSIC or EXM ●...
  • Page 152 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Figure CBCC S30810-Q2935-A401 MPPI or IMODN MUSIC sub- board X30/31 8 x U 2 x S Reset/Reload 4 x T/R P0/E RJ45 keys MPPI, MUSIC or EXM jacks RUN LED V.24 interface, 9-pin SUB-D plug LAN connector, 8-pin RJ45 jack...
  • Page 153 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Figure CBCC S30810-Q2935-A301 MPPI or IMODN MUSIC sub- board X30/31 8 x U 2 x S Reset/Reload 4 x T/R P0/E RJ45 keys MPPI, MUSIC or EXM jacks RUN LED V.24 interface, 9-pin SUB-D plug LAN connector, 8-pin RJ45 jack...
  • Page 154 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board X1 to X4 contact assignments Table 3-4 CBCC - X1 to X4 Contact Assignments Contact Connector X1 Connector X2 Connector X3 Connector X4 MPPI or EXM P0/E port 1b port 5b T/R port 1a P0/E...
  • Page 155 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board V.24 interface assignment Table 3-6 CBCC - V.24 Interface Assignment (SUB-D Plug) X18, Pin Signal Description – Not used RxD A Receive data, channel A TxD A Transmit data, channel A –...
  • Page 156 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Default numbering plan when using CBCC in HiPath 3550 Table 3-8 Default numbering plan when using CBCC in HiPath 3550 Station Int. call no. DID no. Port host P0/E P0/E (master)
  • Page 157 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Default numbering plan when using CBCC in HiPath 3350 Table 3-9 Default numbering plan when using CBCC in HiPath 3350 Station Int. call no. DID no. Port host P0/E P0/E (master)
  • Page 158: Cbrc

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board 3.2.2 CBRC NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 159 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Outputs, interfaces Ethernet (10 BaseT)/10 MBit) LAN interface, only in CBRC S30810-Q2935-Z40 ● The interface can, for example, be used for the following applications: – For administration using HiPath 3000 Manager E –...
  • Page 160 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Switches and indicators Reset/reload switch ● – Switch pressed < 5 s = Reset activated – Switch pressed > 5 s = Reload activated (RUN LED out indicates that a reload is in progress) Run LED ●...
  • Page 161 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Figure CBRC S30810-Q2935-Z401 MPPI, MUSIC EXMR sub- IMODN board 2 x S 8 x U Reset/Reload 4 x T/R P0/E RJ45 keys jacks RUN LED V.24 interface, 9-pin SUB-D plug LAN connector, 8-pin RJ45 jack Figure 3-3...
  • Page 162 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Figure CBRC S30810-Q2935-Z301 MPPI, MUSIC EXMR sub- IMODN board 2 x S 8 x U Reset/Reload 4 x T/R P0/E RJ45 keys jacks RUN LED V.24 interface, 9-pin SUB-D plug LAN connector, 8-pin RJ45 jack Figure 3-4...
  • Page 163 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board X1 and X3 contact assignments Table 3-11 CBRC - X1 and X3 Contact Assignments Contact Connector X1 Connector X3 P0/E port 1a T/R port 1a P0/E port 1b T/R port 1b P0/E port 2a...
  • Page 164 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board V.24 interface assignment Table 3-13 CBRC - V.24 Interface Assignment (SUB-D Plug) X18, Pin Signal Description – Not used RxD A Receive data, channel A TxD A Transmit data, channel A –...
  • Page 165 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Default numbering plan when using CBRC in HiPath 3500 Table 3-15 Default numbering plan when using CBRC in HiPath 3500 Station Int. call no. DID no. Port host P0/E P0/E (master)
  • Page 166 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Default numbering plan when using CBRC in HiPath 3300 Table 3-16 Default numbering plan when using CBRC in HiPath 3300 Station Int. call no. DID no. Port host P0/E P0/E (master)
  • Page 167: Cbsap

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board 3.2.3 CBSAP NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 168 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Switches and indicators Reset/reload switch: ● – Switch pressed < 5 s = Reset activated – Switch pressed > 5 s = Reload activated (Fail LED (red) goes out to indicate that a reload is in progress).
  • Page 169 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Diagram of CBSAP board IMODN LIMS MPPI or MUSIC Subboard Figure 3-5 CBSAP Board (S30810-Q2314-X) A31003-H3590-S100-7-7620, 06/2012 3-37 HiPath 3000/5000 V9, Service documentation...
  • Page 170 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Front panel Two LEDs indicating the board status: Run (green, flashing: 0.5 s on/0.5 s off) = correct, error-free op- ● eration Fail (red) = error encountered ● Reset/reload switch Slide-in shelf for MMC V.24 interfaces (9-pin SUB-D plug):...
  • Page 171 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board V.24 interface assignment Table 3-17 CBSAP - V.24 Interface Assignment (SUB-D Plug) X50/X51, Pin Signal Description Data carrier detect (not used) Receive data Transmit data Data terminal ready (not used) Ground Data send ready (not used) Request to send...
  • Page 172: Cma

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board 3.2.4 Caution Place the central control board on a flat surface before inserting the CMA subboard. The spacing bolts supplied guarantee the correct insertion of the subboard, so you should always mount them (see Figure 3-7).
  • Page 173: Cms

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board 3.2.5 Caution Place the central control board on a flat surface before inserting the CMS subboard. The spacing bolts supplied guarantee the correct insertion of the subboard, so you should always mount them (see Figure 3-7).
  • Page 174 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Table 3-19 Recommendations for CMA and CMS Utilization Trunk Reference HiPath Cordless Trunk Refer- HiPath Cordless connec- clock Office connec- ence Office tion tion clock Networking via ISDN S lines: Master system SLAVE system(s)
  • Page 175 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Table 3-19 Recommendations for CMA and CMS Utilization Trunk Reference HiPath Cordless Trunk Refer- HiPath Cordless connec- clock Office connec- ence Office tion tion clock Networking via Ethernet/IP (10/100 BaseT) lines: System 1 System(s) n+1 No trunk...
  • Page 176: Cuc And Cucr

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board 3.2.6 CUC and CUCR The backplane comes in two versions: CUC (Connection Unit Com) S30777-Q750-X (Figure 3-9) - for use in HiPath 3550 (wall ● housing) CUCR (Connection Unit Com Rack) S30777-Q750-Z (Figure 3-10) - for use in HiPath 3500 ●...
  • Page 177 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Replacing the Backplane Replacing the backplane may be necessary due to contact problems. These are evidenced by the following symptoms: Error messages about various peripheral modules occur. ● Erratic error messages about the CBCC/CBRC and UPSCD modules occur.
  • Page 178: Cup And Cupr

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board 3.2.7 CUP and CUPR The backplane comes in two versions: CUP (Connection Unit Point) S30777-Q751-X (Figure 3-11) - for use in HiPath 3350 (wall ● housing) CUPR (Connection Unit Point Rack) S30777-Q751-Z (Figure 3-12) - for use in HiPath 3300 ●...
  • Page 179 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Replacing the Backplane Replacing the backplane may be necessary due to contact problems. These are evidenced by the following symptoms: Error messages about various peripheral modules occur. ● Erratic error messages about the CBCC/CBRC and UPSCD modules occur.
  • Page 180: Dbsap

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board 3.2.8 DBSAP A prerequisite for expanding HiPath 3800 to a two-cabinet system is that the DBSAP (Driver Board for Synergy Access Platform) board is mounted on the backplane of the expansion cab- inet.
  • Page 181 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board DBSAP Figure 3-14 DBSAP on the Backplane of the Expansion Cabinet A31003-H3590-S100-7-7620, 06/2012 3-49 HiPath 3000/5000 V9, Service documentation...
  • Page 182: Imodn

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board 3.2.9 IMODN Caution Place the central control board on a flat surface before inserting the IMODN sub- board. The spacing bolts supplied guarantee the correct insertion of the subboard, so you should always mount them (see Figure 3-7).
  • Page 183: Lim

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board 3.2.10 Caution The LAN interface module must not be plugged in or out when the system is ener- gized. Place the central control board on a flat surface before inserting the LIM sub- board.
  • Page 184 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board RJ45 jack assignment Table 3-20 LIM - RJ45 Jack Assignment Signal Description Tx + Transmit + Tx – Transmit – Rx + Receive + – Not used – Not used Rx –...
  • Page 185: Lims

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board 3.2.11 LIMS Caution The LIMS module must not be plugged in or out when the system is energized. Introduction The LAN Interface Module for SAPP LIMS (S30807-Q6721-X) is an optional plug-in card for CBSAP central control board in HiPath 3800.
  • Page 186 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Figure 3-15 CBSAP with LIMS Module Plugged In RJ45 jack assignment Table 3-21 LIMS - RJ45 Jack Assignment Signal Description Tx + Transmit + Tx – Transmit – Rx + Receive + –...
  • Page 187: Luna2

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board 3.2.12 LUNA2 Introduction LUNA2 (Linepowered Unit for Network-based Architecture No. 2) is used as the central power supply unit in HiPath 3800. Depending on the system configuration up to three LUNA2 modules can be used in the basic cabinet and up to four LUNA2 modules can be used in the expansion cabinet.
  • Page 188 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Part numbers LUNA2: S30122-K7686-A1, S30122-K7686-M1 ● For production-related reasons, two different LUNA2 modules with the same functions are used. Technically identical, the two models have minor mechanical differences and are ful- ly compatible with each other.
  • Page 189 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Table 3-22 LUNA2 - Bridging Times with 48-V/7-Ah Battery Pack, and Powerbox PB3000 System Power supply unit Load levels Maximum bridg- ing time Measurement conditions: All measurements were performed at a room temperature of approximately 22 °C ●...
  • Page 190 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board – Off = At least one secondary operating voltage is outside the tolerance zone. In this case a) the voltage feed for LUNA2 may not be sufficient (an additional LUNA2 module is required.
  • Page 191 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Slots Push the LUNA2 power supply unit into the slots provided in the lower part of the system cab- inet shelf until you hear a click (see Figure 4-18). The power supply unit slots must be covered with the outer panel shown in Figure 3-17 (basic cabinet) and in Figure 3-18 (expansion cabinet) before the system is started up.
  • Page 192 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Figure 3-18 LUNA2 Slots in the Expansion Cabinet (With Outer Panel Mounted) A31003-H3590-S100-7-7620, 06/2012 3-60 HiPath 3000/5000 V9, Service documentation...
  • Page 193 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Calculating the number of LUNA2 modules required The number of LUNA2 modules required in relation to the number and type of peripheral boards installed can be calculated using the following table. Table 3-23 Determining the Number of LUNA2 Modules Required Per Cabinet Number of peripheral...
  • Page 194: Mmc

    Please note that the MMC may only be replaced by an MMC approved by Siemens Enterprise Communications GmbH & Co. KG. Cards that have not been approved may have a different internal structure which can affect temporal access and certain features (for example, CDB backup and APS transfer).
  • Page 195: Psup

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board 3.2.14 PSUP Introduction The power supply PSUP S30122-K5658-M (Figure 3-19) is used in HiPath 3350 (wall housing). The device plugs into a special slot and is secured by screws. It connects to the power outlet using a modular power cord.
  • Page 196: Rgmod (For Selected Countries Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board 3.2.15 RGMOD (for selected countries only) Introduction The external ring voltage generator RGMOD (S30124-X5109-X) is required for generating ring voltages for the HiPath 3800 SLMA2 board. RGMOD is plugged in on the reverse of the back- plane of the basic and/or expansion cabinet.
  • Page 197 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Ring voltage Ring frequency Setting Standard 65 V 25 Hz Switzerland 75 V 50 Hz France 85 V 20 Hz Table 3-25 RGMOD (Selected Countries Only) - Setting the Ring Voltages and Ring Fre- quencies A31003-H3590-S100-7-7620, 06/2012 3-65...
  • Page 198 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Installing RGMOD The RGMOD ring voltage generator is plugged in at the rear of the backplane. Basic cabinet ● When using one or more SLMA2 boards in the basic cabinet, RGMOD must be plugged into the 10-pin port X214 of the basic cabinet (see Figure 3-20).
  • Page 199 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Expansion cabinet ● When using one or more SLMA2 boards in the expansion cabinet, RGMOD must be plugged into the 10-pin port X214 of the expansion cabinet (see Figure 3-21). X214 Figure 3-21 HiPath 3800 - Connectors and Jacks on the Backplane of the Expansion...
  • Page 200: Upsc-D

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board 3.2.16 UPSC-D Introduction The UPSC-D board (S30122-K5660-A300, S30122-K5660-M300 (Figure 3-22)) is used in Hi- Path 3550 and HiPath 3350 (wall housing). The UPSC-D board supports power supply and bat- tery management functions.
  • Page 201 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Approved battery packs for UPSC-D The following battery packs have been approved and released for operation with the UPSC-D board: 48 V battery pack S30122-K5928-X (4 x 12 V/1.2 Ah) ●...
  • Page 202 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board The batteries were fully charged when the measurement was started. ● The maximum bridging times given in the tables are basic orientation values. They can vary from the values given here depending on your system configuration. Table 3-26 HiPath 3350 –...
  • Page 203 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Diagram of UPSC-D LED, yellow Figure 3-22 UPSC-D (S30122-K5660-M300) Slide switch for setting the ring frequen- LED, green Slide switch for activating/deactivating the battery voltage (battery pack): up = off, battery voltage deactivated ●...
  • Page 204 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Switches and indicators NOTE > System voltage can only be switched on or off by plugging in or out the power plug. If the UPSC-D has been set up for emergency battery operation, the battery voltage must also be switched off.
  • Page 205 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Connectors Port for battery pack or batteries (in PB3000) Port for external power supply unit (in PB3000) Power plug Figure 3-25 UPSC-D - Connectors A31003-H3590-S100-7-7620, 06/2012 3-73 HiPath 3000/5000 V9, Service documentation...
  • Page 206: Upsc-Dr

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board 3.2.17 UPSC-DR Introduction The UPSC-DR board (S30122-K7373-A900, S30122-K7373-M900 (Figure 3-26)) is used in Hi- Path 3500 and HiPath 3300 (19-inch housing). This module supports power supply and battery management functions. No other components are required if it is operated as an AC power supply.
  • Page 207 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Danger Do not use 24-V batteries (S30122-K5403-X) in conjunction with UPSC-DR as an explosive gas (hydrogen + oxygen) escapes when the battery is overloaded. Technical Specifications Nominal voltage range: 100 VAC - 240 VAC ●...
  • Page 208 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Table 3-28 UPSC-DR - Bridging Times with four Batteries V39113-W5123-E891 (4 x 12-V/7-Ah Batteries) and Powerbox PB3000 System Power supply unit Load levels Maximum bridg- ing time Measurement conditions: All measurements were performed at a room temperature of approximately 23 °C ●...
  • Page 209 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Slide switch for setting the ring frequen- LED, green Slide switch for activating and deacti- vating the battery voltage (batteries): up = off, battery voltage deactivated ● LED, yellow (battery backup off) CUCR/CUPR down = on, battery voltage activated...
  • Page 210 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Switches and indicators Caution System voltage can only be switched on or off by plugging in or out the power plug. If using an uninterruptible power supply, switch off the battery voltage first. LED, green: +5-V output voltage is available.
  • Page 211 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Central Board Connectors Connector socket for PB3000, Power plug with batteries and LUNA2 Figure 3-29 UPSC-DR - Connectors A31003-H3590-S100-7-7620, 06/2012 3-79 HiPath 3000/5000 V9, Service documentation...
  • Page 212: Peripheral Boards

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Peripheral boards Important information Caution The system must be powered down and de-energized before removing or inserting any boards in HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300, and before removing or inserting the central boards in HiPath 3800.
  • Page 213: Diu2U (For U.s. Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.1 DIU2U (for U.S. only) Introduction The DIU2U (Digital Interface Unit 2 Universal) trunk module connects two digital trunks to Hi- Path 3800 and in this way provides two primary rate interfaces (PRI) ISDN via T1 interfaces. Connection types Fiber optic cable ●...
  • Page 214 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-29 DIU2U (for U.S. only) - adapter cable assignment (C39195-A7269-B625) 15-pin Sub-D 50-pin Amphenol con- Function Color code connector nector a-wire (T), receive wht/ora b-wire (R), receive ora/wht Front panel Two LEDs indicating the board status:...
  • Page 215 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Table 3-30 DIU2U (for U.S. only) - LED Statuses Red LED Green Status Action Board not receiving power or not plugged in Check plug contact on correctly.
  • Page 216: Diun2

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.2 DIUN2 Introduction The DIUN2 (Digital Interface Unit ISDN) provides 2 x 30 B channels (voice channels) for HiPath 3800. These are used for the S trunk connection (via NT). ●...
  • Page 217 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards An additional shielding panel is not required on the front side of this board, because the EMC shield is already provided by the front panel. LED statuses and their meanings Table 3-31 DIUN2 - LED Statuses Red LED...
  • Page 218 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Connection types Fiber optic cable ● The fiber optic cable is only connected via the front panel. The opto-electronic converter AMOM must be used to connect a fiber optic cable to the 15-pin Sub-D jacks on the front panel.
  • Page 219 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Jack assignment Table 3-32 DIUN2 - 15-Pin Sub-D Jack Assignment Signal Signal description Direction TTIP0 a-wire 120 ohms/75 ohms Output LWLO0_FRONT Fiber optic (data output) Output Ground return path for the +5-V Input/output power supply SCAN_IN0...
  • Page 220: Diut2

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.3 DIUT2 Introduction HiPath 3000/5000 V7 Minor Release 5 and higher supports the use of the DIUT2 board (Digital Interface Unit Trunk 2) in HiPath 3800. The DIUT2 board is a compatible successor to the following boards: DIU2U (S30810-Q2216-X) (for U.S.
  • Page 221 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Front panel Two LEDs indicating the board status: LED (green) ● LED (red) ● 15-pin “Sub-D” interface 1 (X10) 15-pin “Sub-D” interface 2 (X11) Figure 3-33 DIUT2 - Front Panel (S30810-Q2226-X100) An additional shielding panel is not required on the front side of this board, because the EMC shield is already provided by the front panel.
  • Page 222 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Table 3-34 DIUT2 - LED Statuses Red LED Green Status Action Board not receiving power or not plugged in Check plug contact on correctly.
  • Page 223 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Definition of application and connection type The board is configured via the loadware once the application and connection type have been selected. The application type is selected with HiPath 3000/5000 Manager E: System status – Sys- ●...
  • Page 224 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Assigning the “Sub-D” interfaces X10 and X11 Table 3-35 DIUT2 - Assigning the “Sub-D” Interfaces X10 and X11 Signal Signal description Direction TTIP0 a-wire 120 ohms/75 ohms Output LWLO0_FRONT Fiber optic (data output) Output...
  • Page 225 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Signal Name Connector contact Signal description Direction BGx_0A, X1-02, X1-26 Sets 0 to 7 AB pair Not connected BGx_0B X1-06, X1-08 X1-10, X2-02 X2-04, X2-06 X2-08, X2-10 X3-02, X3-04 X3-06, X3-08 X3-10, X4-02 HO0 …...
  • Page 226 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Signal Name Connector contact Signal description Direction X7-46 Boundary scan: check mode Not connected selection X7-48 Boundary scan: Check data Not connected input X7-50 Boundary scan: Check data Not connected output Table 3-36...
  • Page 227: Hxgs3, Hxgr3

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.4 HXGS3, HXGR3 Introduction HXGS3 and HXGR3 are VoIP gateway boards (VoIP - Voice over IP) that provide the function- ality of HG 1500 in HiPath 3550, HiPath 3350 (HXGS3), and HiPath 3500, HiPath 3300 (HXGR3): Connection of a local LAN to the HiPath 3000 and connection with external LANs via the ●...
  • Page 228 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Upgrade, fan kit If the following housing covers are available on the HiPath 3350 and HiPath 3550 systems, a fan kit is not required when upgrading with a HXGS3: HiPath 3350: from housing cover C39165-A7021-B53 ●...
  • Page 229 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Extension modules The HXGS3 and HXGR3 boards each have two HGA (HiPath Gateway Accelerator) slots, which can be used to connect extension modules. Table 3-39 HXGS3/HXGR3 - Extension Modules Extension module Part number Function Notes...
  • Page 230 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Interfaces/connectors The HXGS3 and HXGR3 boards provide the following connectors: X1: 50-pin connector (edge connector) to the system ● X2: 8-pin RJ45 jack for LAN interface 1 ● X3: 8-pin RJ45 jack for LAN interface 2 ●...
  • Page 231 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LAN interfaces Table 3-40 HXGS3/HXGR3 - LAN Interface Assignment Pin on Pin of RJ45 con- Signal HXGS3/HXGR3 nector (X2 and X3) TDP (Transmit Data +) TDN (Transmit Data –) RDP (Receive Data +) –...
  • Page 232 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards V.24 interface V.24 cable (C30267-Z355-A25) is used for connecting the service PC. The following settings must be chosen for a terminal or PC connected to the V.24 interface: Transmission rate 19,200 Data bits...
  • Page 233: Ivmnl, Ivmn8

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.5 IVMNL, IVMN8 Introduction The IVMNL and IVMNL8 (Integrated Voice Mail New Large) boards allow you to use the HiPath Xpressions Compact integrated voice mail functionality in HiPath 3800: IVMNL (S30122-H7688-X) = 24 ports ●...
  • Page 234 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Front panel Two LEDs indicating the board status: LED (green) ● LED (yellow) ● Lockout switch Ethernet (10/100BaseT) interface (8-pin RJ45 jack) Figure 3-37 IVMNL, IVMN8 - Front Panel (S30122-H7688-X -X100) An additional shielding panel is not required on the front side of this board, because the EMC shield is already provided by the front panel.
  • Page 235 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Lockout switch settings Pressed = free (default) ● Not pressed = locked: existing connections remain active, new connections are locked. ● – The yellow LED lights up when all connections are ended and the board is effectively locked.
  • Page 236 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-42 IVMNL, IVMN8 - LED Statuses Meaning Action yellow green Flashing At least one active port (call) (500/ 500 ms) Flashing Flashing Lockout switch activated during a call (500/ (500/ 500 ms)
  • Page 237: Ivmp4, Ivmp4R

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.6 IVMP4, IVMP4R Introduction The following boards are used for the integrated voice mail functionality in HiPath Xpressions Compact in V2.5 and later: IVMP4 (Integrated Voice Mail Point) S30122-Q7004-X13 - for HiPath 3550 and HiPath ●...
  • Page 238 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Switches and LEDs X1 = con- Lockout switch nection to LED (green) CUC/ LED (yellow) CUCR/ X3 = LAN CUP/ connector, CUPR 8-pin RJ45 jack Figure 3-38 IVMP4, IVMP4R Lockout switch settings Pressed = free (default) ●...
  • Page 239 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Assignment of the RJ45 jack X3 The Ethernet (10/100BaseT) interface is accessed via the 8-pin RJ45 jack X3. RJ45 Jack X3 Signal Description Tx + Transmit + Tx – Transmit –...
  • Page 240 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Meaning Action yellow green During Startup and Initialization 1 Boot procedure (lasts approx. 60 s) 2 LED test (lasts approx. 10 s) 3 Lockout switch state signaling by Possibly check if board was de- yellow LED (lasts approx.
  • Page 241: Ivmp8 (Not For U.s.) And Ivmp8R (Not For U.s.)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.7 IVMP8 (not for U.S.) and IVMP8R (not for U.S.) Introduction The following boards are used for the integrated voice mail functionality in HiPath Xpressions Compact in V1.2 and later: IVMP8 (Integrated Voice Mail Point) S30122-Q7379-X100 - for HiPath 3350 (wall housing) ●...
  • Page 242 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Packing protection covering You must remove the red packing protection covering (cardboard block), shown in the following picture, before starting up the board. If it is necessary to transport the board again at a later time, for example, for servicing, you must reattach the packing protection covering.
  • Page 243 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Switches and LEDs X1 = con- Lockout switch nection to- LED (green) CUP/ LED (yellow) CUPR X3 = LAN connector, 8-pin RJ45 jack Figure 3-40 IVMP8, IVMP8R (S30122-Q7379-X100, -K7379-Z100) (not for U.S.) Lockout switch settings Pressed = free (default) ●...
  • Page 244 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Assignment of the RJ45 jack X3 The Ethernet (10/100BaseT) interface is accessed via the 8-pin RJ45 jack X3. The signals are output simultaneously at the printed circuit connector X2. Table 3-46 IVMP8 and IVMP8R (not for U.S.) - Assignment of the RJ45 Jack X3 (LAN Connector)
  • Page 245 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Table 3-47 IVMP8 and IVMP8R (not for U.S.) - LED Statuses Meaning Action yellow green During Startup and Initialization 1 Boot procedure (lasts approx. 8 - 12 2 LED test (lasts approx.
  • Page 246: Ivms8, Ivms8R

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.8 IVMS8, IVMS8R Introduction The following boards are used for the integrated voice mail functionality in HiPath Xpressions Compact in V1.2 and later: IVMS8 (Integrated Voice Mail Small) S30122-Q7379-X - for HiPath 3550 and HiPath 3350 ●...
  • Page 247 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Packing protection covering You must remove the red packing protection covering (cardboard block), shown in the following picture, before starting up the board. If it is necessary to transport the board again at a later time, for example, for servicing, you must reattach the packing protection covering.
  • Page 248 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Switches and LEDs X1 = con- Lockout switch nection to LED (green) CUC/ LED (yellow) CUCR/ X3 = LAN CUP/ connector, CUPR 8-pin RJ45 jack Figure 3-42 IVMS8, IVMS8R (S30122-Q7379-X, -K7379-Z) Lockout switch settings Pressed = free (default) ●...
  • Page 249 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Front view of IVMS8R X3 = LAN connector, 8-pin RJ45 jack LED (yellow) LED (green) Lockout switch Figure 3-43 IVMS8R - Front View (S30122-K7379-Z) A31003-H3590-S100-7-7620, 06/2012 3-117 HiPath 3000/5000 V9, Service documentation...
  • Page 250 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Assignment of the RJ45 jack X3 The Ethernet (10/100BaseT) interface is accessed via the 8-pin RJ45 jack X3. The signals are output simultaneously at the printed circuit connector X2. Table 3-48 IVMS8, IVMS8R - Assignment of the RJ45 Jack X3 (LAN Connector) RJ45 Jack X3...
  • Page 251 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Table 3-49 IVMS8, IVMS8R - LED Statuses Meaning Action yellow green During Startup and Initialization 1 Boot procedure (lasts approx. 8 - 12 s) 2 LED test (lasts approx.
  • Page 252: Ivms8N, Ivms8Nr

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.9 IVMS8N, IVMS8NR Introduction The following boards are used for the integrated voice mail functionality in HiPath Xpressions Compact in V2.5 and later: IVMS8N (Integrated Voice Mail Small New) S30122-Q7379-X200 - for HiPath 3550 and Hi- ●...
  • Page 253 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Switches and LEDs X1 = con- Lockout switch nection to LED (green) CUC/ LED (yellow) CUCR/ X3 = LAN CUP/ connector, CUPR 8-pin RJ45 jack Figure 3-44 IVMS8N, IVMS8NR Lockout switch settings Pressed = free (default) ●...
  • Page 254 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Assignment of the RJ45 jack X3 The Ethernet (10/100BaseT) interface is accessed via the 8-pin RJ45 jack X3. RJ45 Jack X3 Signal Description Tx + Transmit + Tx – Transmit –...
  • Page 255 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Meaning Action yellow green During Startup and Initialization 1 Boot procedure (lasts approx. 60 2 LED test (lasts approx. 10 s) 3 Lockout switch state signaling by Possibly check if board was de- yellow LED (lasts approx.
  • Page 256: Sla8N (Not For U.s.), Sla16N, Sla24N

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.10 SLA8N (not for U.S.), SLA16N, SLA24N NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 257 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Table 3-52 SLA8N (not for U.S.), SLA16N, SLA24N - LED Statuses Red LED Green Status Action Board not receiving power or not plugged in Check plug contact on correctly.
  • Page 258 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Cable and connector assignment (backplane, MDFU/MDFU-E, patch panel) Table 3-53 SLA8N, SLA16N, SLA24N Assignment Cable 1 (SU Xx8) (not for U.S.) SU con- SLA8N, Color a-wire b-wire MDFU/ Patch Panel, nector Pair...
  • Page 259 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-54 SLA8N, SLA16N, SLA24N - Assignment Cable 2 (SU Xx9) (not for U.S.) SU con- SLA8N, Color a-wire b-wire MDFU/ Patch Panel, nector Pair SLA16N, Notes group (tip) (ring)1 MDFU-E...
  • Page 260 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-55 SLA16N, SLA24N - Assignment (SU Xx8, Xx9) (for U.S. only) SU connector a-wire b-wire SLA16N, SLA24N CHAMP jack, MDF Notes (tip) (ring)1 BP: Xx8 BP: Xx9 wht/blu Port 1 blu/wht...
  • Page 261 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-55 SLA16N, SLA24N - Assignment (SU Xx8, Xx9) (for U.S. only) SU connector a-wire b-wire SLA16N, SLA24N CHAMP jack, MDF Notes (tip) (ring)1 BP: Xx8 BP: Xx9 red/brn Port 17 brn/red...
  • Page 262: Slad4, Slad8, Slad8R

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.11 SLAD4, SLAD8, SLAD8R NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 263 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards SLAD4, SLAD8 interfaces T/R ports 1-4 CUP/CUC T/R port 5-8 (not SLAD4) Figure 3-46 SLAD4, SLAD8 - interfaces Table 3-56 SLAD4, SLAD8 - assigning the ports X2, Pin T/R ports 1-4 X3, Pin T/R ports 5-8...
  • Page 264 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards SLAD8R interfaces Port 1 T/R ports 1–8 CUPR / CUCR (4-pin MW8 jacks Port 8 Figure 3-47 SLAD8R - interfaces Table 3-57 SLAD8R - assigning the ports MW8 jack X2, Pin T/R ports 1-4 MW8 jack...
  • Page 265: Slad16

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.12 SLAD16 NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 266 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Configuration rules for HiPath 3550 The following table provides which slots have to be used by SLAD16 boards in which sequence depending on the number of analog station ports which have to be realized; and it provides if the fan kit C39165-A7021-B46-1 and/or the Power Box PB3000 have to be assembled.
  • Page 267 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Tabelle 3-58 Decision array for HiPath 3550: Assembly of fan kit and Power Box CBCC (4 a/b ports, Slot Loop current Fan kit Power ports) Number of analog ports 20.5 23.2 28.2...
  • Page 268 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Interfaces T/R ports 1-4 T/R ports 5-8 CUP/CUC T/R ports 9-12 T/R ports 13-16 Figure 3-48 SLAD16 – Interfaces Table 3-59 SLAD16 – Port Assignment X2, Pin T/R ports X3, Pin T/R ports X4, Pin...
  • Page 269 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Installing fan kit C39165-A7021-B46-1 for SLAD16 in HiPath 3550 NOTE > Installing the fan kit marks the end of silent system operation. This must be taken into consideration when operating the system in an office environment. To install and connect the fan kit, proceed as follows: Step Activity...
  • Page 270 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Step Activity Close the system. CAUTION Cuts caused by sharp edges on the shielding plate When opening the system, ensure that you only touch the housing cover from the outside.
  • Page 271 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Figure 3-50 SLAD16 - Fan Kit Connection Cable Figure 3-51 SLAD16 - Connection of the Fan Kit A31003-H3590-S100-7-7620, 06/2012 3-139 HiPath 3000/5000 V9, Service documentation...
  • Page 272: Slc16N (Not For U.s.)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.13 SLC16N (not for U.S.) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 273 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Switches and LEDs LED (green) LED (red) Lockout switch (not pressed = free, factory default) Figure 3-52 SLC16N (S30810-Q2193-X100) (not for U.S.) When you activate the lockout switch (press the switch), all idle mobile telephones >...
  • Page 274 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Table 3-60 SLC16N (not for U.S.) - LED Statuses Red LED Green Status Action Board not receiving power or not plugged in Check plug contact on correctly.
  • Page 275 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Cable and connector assignment (backplane, MDFU/MDFU-E, patch panel) Table 3-61 SLC16N (not for U.S.) - Cable Assignment SU con- Patch Pan- Color a-wire b-wire MDFU/ nector Pair SLC16N Notes group (tip)
  • Page 276 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards System configuration using SLC16N For information on the maximum possible system configuration of HiPath Cordless Office with SLC16N boards, see Table 11-1. Supplying power to base stations Power is supplied to the base stations primarily via the internal PSU in the system in question. HiPath 3550 ●...
  • Page 277 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-62 HiPath 3550 - Maximum Number of Corded Telephones Depending on the Number of BS3/1 Base Stations Connected to SLC16N and BS4s con- nected to SLC16N (not for U.S.) Number Maximum number of corded telephones of BS3/1s and BS4s...
  • Page 278 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Options for supplying power to the base stations For information on connecting the base stations, refer to the HiPath Cordless Office > service manual. Each base station must be connected to the SLC16N via the main distribution frame (MDFU or MDFU-E).
  • Page 279 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Base Station Power Supply via One U Interface P0/E Connect the base station to a free interface on SLC16N as shown in Figure 3-53. Be careful not to exceed the maximum connection cable lengths (1000 m for 2 x 0.6 mm). HiPath 3550 BS3/1 for in- doors...
  • Page 280 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Base station power supply via two U interfaces P0/E Connect the base station to two free interfaces on SLC16N as shown in Figure 3-54. Be careful not to exceed the maximum connection cable lengths (1000 m for 2 x 0.6 mm). Using two U interfaces increases the traffic capacity in BS3/3 base stations.
  • Page 281 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Base Station Power Supply via Three U Interfaces P0/E Connect the base station to three free interfaces on SLC16N as shown in Figure 3-55. Be care- ful not to exceed the maximum connection cable lengths (1000 m for 2 x 0.6 mm). The use of three U interfaces increases the traffic capacity in the base station.
  • Page 282: Slcn (Not For U.s.)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.14 SLCN (not for U.S.) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 283 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Table 3-64 SLCN (not for U.S.) - LED Statuses Red LED Green Status Action Board not receiving power or not plugged in Check plug contact on correctly.
  • Page 284 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-65 SLCN (not for U.S.) - SIVAPAC Connector Assignment on the Backplane a-wire b-wire Pair SIVAPAC connector SLCN MDFU-E Notes (tip) (ring)1 wht/blu Port 1 blu/wht wht/ora Port 2 ora/wht wht/grn...
  • Page 285 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-66 SLCN (not for U.S.) - Assignment of Connector Panels with RJ45 Jacks RJ45 jack SLCN Notes A31003-H3590-S100-7-7620, 06/2012 3-153 HiPath 3000/5000 V9, Service documentation...
  • Page 286 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-66 SLCN (not for U.S.) - Assignment of Connector Panels with RJ45 Jacks RJ45 jack SLCN Notes Free Free Free Free Free Free Free Free A31003-H3590-S100-7-7620, 06/2012 3-154 HiPath 3000/5000 V9, Service documentation...
  • Page 287 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-67 SLCN (not for U.S.) - Assignment of Connector Panels with SIPAC 1 SU Con- nectors (Cable for Ports 1 - 16) Color a-wire b-wire SU con- Patch Panel, Pair SLCN...
  • Page 288 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards System Configuration Using SLCN For information on the maximum possible system configuration of HiPath Cordless Office with the SLCN boards see Table 11-1. SLCN board distribution in HiPath 3800 cabinets You can install up to four SLCN boards in HiPath 3800.
  • Page 289: Slmae8, Slmae (Slmae200)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.15 SLMAE8, SLMAE (SLMAE200) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 290 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Touch guard CAUTION Risk of electric shock through contact with live components The boards are fitted with a touch guard because the onboard heat sinks are ener- gized. Do not remove this touch guard. Figure 3-57 SLMAE8, SLMAE - Touch Guard Front panel...
  • Page 291 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Cover To ensure sufficient shielding, provide the board with a shielding panel. For information on mounting the shielding panel, see Section 4.1.5.3. LED statuses and their meanings Table 3-68 SLMAE8, SLMAE - LED Statuses Red LED Green...
  • Page 292 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-69 SLMAE8, SLMAE - SIVAPAC Connector Assignment on the Backplane a-wire b-wire Pair SIVAPAC connector SLMAE8, SLMAE MDFU-E Notes (tip) (ring)1 wht/blu Port 1 blu/wht wht/ora Port 2 ora/wht wht/grn Port 3...
  • Page 293 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-69 SLMAE8, SLMAE - SIVAPAC Connector Assignment on the Backplane a-wire b-wire Pair SIVAPAC connector SLMAE8, SLMAE MDFU-E Notes (tip) (ring)1 yel/ora Port 17 ora/yel yel/grn Port 18 grn/yel yel/brn Port 19...
  • Page 294 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-70 SLMAE8, SLMAE - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLMA8, Notes SLMAE Not used for SLMAE8 A31003-H3590-S100-7-7620, 06/2012 3-162 HiPath 3000/5000 V9, Service documentation...
  • Page 295 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-70 SLMAE8, SLMAE - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLMA8, Notes SLMAE Not used for SLMAE8 A31003-H3590-S100-7-7620, 06/2012 3-163 HiPath 3000/5000 V9, Service documentation...
  • Page 296 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-71 SLMAE8, SLMAE - Connector Panel Assignment with CHAMP Jack (for U.S. only) CHAMP jack SLMAE8, SLMAE Notes 1 Ring Port 1 1 TIP 2 Ring Port 2 2 TIP 3 Ring Port 3...
  • Page 297 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-71 SLMAE8, SLMAE - Connector Panel Assignment with CHAMP Jack (for U.S. only) CHAMP jack SLMAE8, SLMAE Notes 17 Ring Port 17 17 TIP 18 Ring Port 18 18 TIP 19 Ring Port 19...
  • Page 298 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-72 SLMAE8, SLMAE - Connector Panel Assignment with SIPAC 1 SU Connectors (Cable for ports 1 - 16) Color a-wire b-wire SU con- SLMA8, Patch Panel, Pair MDFU-E Notes Group...
  • Page 299 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-73 SLMAE8, SLMAE - Connector Panel Assignment with SIPAC 1 SU Connectors (Cable for ports 17 - 24) Color a-wire b-wire SU con- SLMA8, Patch Panel, Pair MDFU-E Notes Group...
  • Page 300: Slma, Slma8

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.16 SLMA, SLMA8 NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 301 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Cover To ensure sufficient shielding, provide the board with a shielding panel. For information on mounting the shielding panel, see Section 4.1.5.3. LED statuses and their meanings Table 3-74 SLMA/SLMA8 - LED Statuses Red LED Green...
  • Page 302 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-75 SLMA/SLMA8 - SIVAPAC Connector Assignment on the Backplane a-wire b-wire Pair SIVAPAC connector SLMA, SLMA8 MDFU-E Notes (tip) (ring)1 wht/blu Port 1 blu/wht wht/ora Port 2 ora/wht wht/grn Port 3...
  • Page 303 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-75 SLMA/SLMA8 - SIVAPAC Connector Assignment on the Backplane a-wire b-wire Pair SIVAPAC connector SLMA, SLMA8 MDFU-E Notes (tip) (ring)1 yel/ora Port 17 ora/yel yel/grn Port 18 grn/yel yel/brn Port 19...
  • Page 304 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-76 SLMA/SLMA8 - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLMA, SLMA8 Notes Not used for SLMA8 A31003-H3590-S100-7-7620, 06/2012 3-172 HiPath 3000/5000 V9, Service documentation...
  • Page 305 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-76 SLMA/SLMA8 - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLMA, SLMA8 Notes Not used for SLMA8 A31003-H3590-S100-7-7620, 06/2012 3-173 HiPath 3000/5000 V9, Service documentation...
  • Page 306 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-77 SLMA/SLMA8 - Connector Panel Assignment with CHAMP Jack (for U.S. only) CHAMP jack SLMA, SLMA8 Notes 1 Ring Port 1 1 TIP 2 Ring Port 2 2 TIP 3 Ring Port 3...
  • Page 307 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-77 SLMA/SLMA8 - Connector Panel Assignment with CHAMP Jack (for U.S. only) CHAMP jack SLMA, SLMA8 Notes 17 Ring Port 17 17 TIP 18 Ring Port 18 18 TIP 19 Ring Port 19...
  • Page 308 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-78 SLMA, SLMA8 - Connector Panel Assignment with SIPAC 1 SU Connectors (Cable for Ports 1 - 16) Color a-wire b-wire SU con- Patch Panel, Pair SLMA, SLMA8 MDFU-E Notes Group...
  • Page 309 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-79 SLMA, SLMA8 - Connector Panel Assignment with SIPAC 1 SU Connectors (Cable for Ports 17 - 24) Color a-wire b-wire SU con- Patch Panel, Pair SLMA, SLMA8 MDFU-E Notes Group...
  • Page 310: Slma2 (For Selected Countries Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.17 SLMA2 (for selected countries only) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 311 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards To ensure sufficient shielding, provide the board with a shielding panel. For informa- > tion on mounting the shielding panel, see Section 4.1.5.3. A31003-H3590-S100-7-7620, 06/2012 3-179 HiPath 3000/5000 V9, Service documentation...
  • Page 312 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Table 3-80 SLMA2 (for selected countries only) - LED Statuses Red LED Green Status Action Board not receiving power or not plugged in Check plug contact on correctly.
  • Page 313 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-81 SLMA2 (Selected Countries Only) - SIVAPAC Connector Assignment on the Backplane a-wire b-wire Pair SIVAPAC connector SLMA2 MDFU-E Notes (tip) (ring)1 wht/blu Port 1 blu/wht wht/ora Port 2 ora/wht wht/grn...
  • Page 314 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-81 SLMA2 (Selected Countries Only) - SIVAPAC Connector Assignment on the Backplane a-wire b-wire Pair SIVAPAC connector SLMA2 MDFU-E Notes (tip) (ring)1 yel/blu Port 16 blu/yel yel/ora Port 17 ora/yel yel/grn...
  • Page 315 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-82 SLMA2 (Selected Countries Only) - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLMA2 Notes A31003-H3590-S100-7-7620, 06/2012 3-183 HiPath 3000/5000 V9, Service documentation...
  • Page 316 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-82 SLMA2 (Selected Countries Only) - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLMA2 Notes A31003-H3590-S100-7-7620, 06/2012 3-184 HiPath 3000/5000 V9, Service documentation...
  • Page 317 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-83 SLMA2 (Selected Countries Only) - Connector Panel Assignment with CHAMP Jacks (U.S. only) CHAMP jack SLMA2 Notes 1 Ring Port 1 1 TIP 2 Ring Port 2 2 TIP 3 Ring Port 3...
  • Page 318 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-83 SLMA2 (Selected Countries Only) - Connector Panel Assignment with CHAMP Jacks (U.S. only) CHAMP jack SLMA2 Notes 17 Ring Port 17 17 TIP 18 Ring Port 18 18 TIP 19 Ring Port 19...
  • Page 319 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-84 SLMA2 (for selected countries only) - Connector Panel Assignment with SIPAC 1 SU Connectors (Cable for Ports 1 - 16) Color a-wire b-wire SU con- Patch Panel, Pair SLMA2 MDFU-E...
  • Page 320 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-85 SLMA2 (for selected countries only) - Connector Panel Assignment with SIPAC 1 SU Connectors (Cable for Ports 17 - 24) Color a-wire b-wire SU con- Patch Panel, Pair SLMA2 MDFU-E...
  • Page 321: Slmav8, Slmav24

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.18 SLMAV8, SLMAV24 NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 322 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Product image SLMAV8 SLMAV24 Figure 3-61 SLMAV8, SLMAV24 Front panel Two LEDs indicating the board status: LED (red) ● LED (green) ● Figure 3-62 SLMAV8, SLMAV24 – LEDs in the front panel Cover To ensure sufficient shielding, provide the board with a shielding panel.
  • Page 323 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Table 3-86 SLMAV8, SLMAV24 – LED statuses Red LED Green Status Action Board not receiving power or not plugged in Check plug contact on correctly.
  • Page 324 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-87 SLMAV8, SLMAV24 - SIVAPAC Connector Assignment on the Backplane a-wire b-wire Pair SIVAPAC connector SLMAV8, SLMAV24 MDFU-E Notes (tip) (ring)1 wht/blu Port 1 blu/wht wht/ora Port 2 ora/wht wht/grn Port 3...
  • Page 325 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-87 SLMAV8, SLMAV24 - SIVAPAC Connector Assignment on the Backplane a-wire b-wire Pair SIVAPAC connector SLMAV8, SLMAV24 MDFU-E Notes (tip) (ring)1 yel/ora Port 17 ora/yel yel/grn Port 18 grn/yel yel/brn Port 19...
  • Page 326 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-88 SLMAV8, SLMAV24 - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLMAV8, Notes SLMAV24 not used in SLMAV8 A31003-H3590-S100-7-7620, 06/2012 3-194 HiPath 3000/5000 V9, Service documentation...
  • Page 327 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-88 SLMAV8, SLMAV24 - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLMAV8, Notes SLMAV24 not used in SLMAV8 A31003-H3590-S100-7-7620, 06/2012 3-195 HiPath 3000/5000 V9, Service documentation...
  • Page 328 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-89 SLMAV8, SLMAV24 - Connector Panel Assignment with CHAMP Jack (for U.S. only) CHAMP jack SLMAV8, SLMAV24 Notes 1 Ring Port 1 1 TIP 2 Ring Port 2 2 TIP 3 Ring Port 3...
  • Page 329 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-89 SLMAV8, SLMAV24 - Connector Panel Assignment with CHAMP Jack (for U.S. only) CHAMP jack SLMAV8, SLMAV24 Notes 17 Ring Port 17 17 TIP 18 Ring Port 18 18 TIP 19 Ring Port 19...
  • Page 330 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-90 SLMAV8, SLMAV24 - Connector Panel Assignment with SIPAC 1 SU Connec- tors (Cable for ports 1 - 16) Color a-wire b-wire SU con- SLMAV8, Patch Panel, Pair MDFU-E Notes...
  • Page 331 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-91 SLMAV8, SLMAV24 - Connector Panel Assignment with SIPAC 1 SU Connec- tors (Cable for ports 17 - 24) Color a-wire b-wire SU con- SLMAV8, Patch Panel, Pair MDFU-E Notes...
  • Page 332: Slmo2, Slmo8

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.19 SLMO2, SLMO8 NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 333 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Table 3-92 SLMO2 and SLMO8 - LED Statuses Red LED Green Status Action Board not receiving power or not plugged in Check plug contact on correctly.
  • Page 334 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-93 SLMO2/SLMO8 - SIVAPAC Connector Assignment on the Backplane a-wire b-wire Pair SIVAPAC connector SLMO2, SLMO8 MDFU-E Notes (tip) (ring)1 wht/blu Port 1 blu/wht wht/ora Port 2 ora/wht wht/grn Port 3...
  • Page 335 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-93 SLMO2/SLMO8 - SIVAPAC Connector Assignment on the Backplane a-wire b-wire Pair SIVAPAC connector SLMO2, SLMO8 MDFU-E Notes (tip) (ring)1 yel/ora Port 17 ora/yel yel/grn Port 18 grn/yel yel/brn Port 19...
  • Page 336 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-94 SLMO2/SLMO8 - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLMO2, SLMO8 Notes Not used for SLMO8 A31003-H3590-S100-7-7620, 06/2012 3-204 HiPath 3000/5000 V9, Service documentation...
  • Page 337 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-94 SLMO2/SLMO8 - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLMO2, SLMO8 Notes Not used for SLMO8 A31003-H3590-S100-7-7620, 06/2012 3-205 HiPath 3000/5000 V9, Service documentation...
  • Page 338 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-95 SLMO2/SLMO8 - Connector Panel Assignment with CHAMP Jack (for U.S. only) CHAMP jack SLMO2, SLMO8 Notes 1 Ring Port 1 1 TIP 2 Ring Port 2 2 TIP 3 Ring Port 3...
  • Page 339 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-95 SLMO2/SLMO8 - Connector Panel Assignment with CHAMP Jack (for U.S. only) CHAMP jack SLMO2, SLMO8 Notes 17 Ring Port 17 17 TIP 18 Ring Port 18 18 TIP 19 Ring Port 19...
  • Page 340 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-96 SLMO2/SLMO8 - Connector Panel Assignment with SIPAC 1 SU Connectors (Cable for Ports 1 - 16) Color a-wire b-wire SU con- Patch Panel, Pair SLMO2, SLMO8 MDFU-E Notes Group...
  • Page 341 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-97 SLMA, SLMA8 - Connector Panel Assignment with SIPAC 1 SU Connectors (Cable for Ports 17 - 24) Color a-wire b-wire SU con- Patch Panel, Pair SLMA, SLMA8 MDFU-E Notes Group...
  • Page 342: Slmo8 (Not For U.s.), Slmo24

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.20 SLMO8 (not for U.S.), SLMO24 NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 343 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Table 3-98 SLMO8 (not for U.S.) and SLMO24 - LED Statuses Red LED Green Status Action Board not receiving power or not plugged in Check plug contact on correctly.
  • Page 344 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Cable and connector assignment (backplane, MDFU/MDFU-E, patch panel) Table 3-99 SLMO8 (not for U.S.), SLMO24 - Cable 1 Assignment (SU Xx8) SU con- Color a-wire b-wire SLMO8, MDFU/ Patch Panel, nector Pair...
  • Page 345 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-100 SLMO8 (not for U.S.), SLMO24 - Cable 2 Assignment (SU Xx9) SU con- Color a-wire b-wire SLMO8, MDFU/ Patch Panel, nector Pair Notes Group (ring)1 SLMO24 MDFU-E MW8 pin (tip)
  • Page 346 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-101 SLMO24 - Assignment (SU Xx8, Xx9) (for U.S. only) SU connector a-wire b-wire SLMO24 CHAMP jack, MDF Notes (tip) (ring)1 BP: Xx8 BP: Xx9 wht/blu Port 1 blu/wht wht/ora Port 2...
  • Page 347 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-101 SLMO24 - Assignment (SU Xx8, Xx9) (for U.S. only) SU connector a-wire b-wire SLMO24 CHAMP jack, MDF Notes (tip) (ring)1 BP: Xx8 BP: Xx9 red/brn Port 17 brn/red red/gry Port 18...
  • Page 348: Slu8

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.21 SLU8 NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 349 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-102 SLU8 Contact Assignments Contact X2 (U ports 1-4) X3 (U ports 5-8) Po/E P0/E A31003-H3590-S100-7-7620, 06/2012 3-217 HiPath 3000/5000 V9, Service documentation...
  • Page 350: Slu8R

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.22 SLU8R NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 351 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-103 SLU8R Contact Assignments X2, Pin ports X2, Pin ports P0/E P0/E jack jack A31003-H3590-S100-7-7620, 06/2012 3-219 HiPath 3000/5000 V9, Service documentation...
  • Page 352: Stls2 (Not For U.s.), Stls4

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.23 STLS2 (not for U.S.), STLS4 NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 353 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Interface Assignments (for U.S. only) Table 3-104 STLS4 Module Interface Assignments (for U.S. only) Port Assignment Port Assignment Transmit Transmit Receive Receive Receive Receive Transmit Transmit Transmit Transmit Receive Receive Receive...
  • Page 354 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Connecting ISDN (S ) interfaces (not for U.S.) You can use the MW jacks on the STLS boards to connect between one and four ISDN S bus- es. The interfaces on the STLS boards are freely configurable. EURO CO point-to-point ●...
  • Page 355 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Connecting ISDN terminals (not for U.S.) Depending on the system, you can set up a maximum of four internal S buses (S 1 to S A maximum of eight ISDN terminals can be addressed on each S bus.
  • Page 356 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards System Mini-Western 1 to S through-jack (MW8 = 8-pin) SR.1 Receive 5 SX.1 Transmit 3 Twisted To switch from external to inter- SX.2 Transmit 6 pair 7 6 5 4 3 2 SR.2 Receive 4 nal S operation, you must first...
  • Page 357 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Connecting ISDN Terminals to HiPath 3550 and HiPath 3350 (for U.S. only) Bus With MW8 jack, connecting S 1 to S ● – Connect the provided, silver-satin connector cord to each port on the STLS4 Module. Connect the other end to a mounted MW jack, reversing the transmit and receive wires.
  • Page 358: Stls4R

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.24 STLS4R NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 359 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-105 STLS4R Contact Assignments MW8 (RJ45) Jack X2, Pin Ports 1-4 port 1 transmit+ port 1 receive+ port 1 receive– port 1 transmit– port 2 transmit+ port 2 receive+ port 2 receive–...
  • Page 360: Stlsx2, Stlsx4, Stlsx4R

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.25 STLSX2, STLSX4, STLSX4R NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 361 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards port 1 CUP/CUC (for STLSX2/ ports STLSX4) (MW8 (RJ45)- jacks) CUPR/CUCR port 4 (for STLSX4R) ports 3 and 4 are not assigned in STLSX2..MW8 (RJ45) jack assignment: 3 = Transmit + 4 = Receive + 5 = Receive –...
  • Page 362 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Configuring S interfaces Depending on how the interfaces are applied, use HiPath 3000/5000 Manager E to define the relevant protocols for the trunks to be connected. Please note the additional information con- tained in the protocol templates when selecting a suitable S protocol: CO = Interfaces to the public CO...
  • Page 363 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Connecting ISDN telephones Depending on the system, you can set up a maximum of four internal S buses (S 1 to S A maximum of eight ISDN terminals can be addressed on each S bus.
  • Page 364 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards System Mini-Western 1 to S through-jack (MW8 = 8-pin) SR.1 Receive 5 SX.1 Transmit 3 Twisted To switch from external to inter- SX.2 Transmit 6 pair 7 6 5 4 3 2 SR.2 Receive 4 nal S operation, you must first...
  • Page 365: Stmd3

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.26 STMD3 NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 366 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Table 3-107 STMD3 - LED Statuses Red LED Green Status Action Board not receiving power or not plugged in Check plug contact on correctly.
  • Page 367 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-108 STMD3 - SIVAPAC Connector Assignment on the Backplane a-wire b-wire Pair SIVAPAC connector STMD3 MDFU-E Notes (tip) (ring)1 wht/blu blu/wht Basic rate access 1 wht/ora ora/wht wht/grn grn/wht Basic...
  • Page 368 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-109 STMD3 - Connector Panel Assignment with RJ45 Jacks RJ45 jack STMD3 Notes Subscriber line Trunk connection Basic rate access 1 Basic rate access 2 Basic rate access 3 Basic rate access 4 Basic...
  • Page 369 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-110 STMD3 - Connector Panel Assignment with CHAMP Jack (for U.S. only) CHAMP jack STMD3 Notes , Receive , Receive Basic rate access 1 , Transmit , Transmit , Receive , Receive Basic...
  • Page 370 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-111 STMD3 - Connector Panel Assignment with SIPAC 1 SU Connectors (Cable for Ports 1 - 16) patch panel, MW8 pin Color a-wire b-wire Pair STMD3 MDFU-E group (tip) (ring)1...
  • Page 371: Stmi2

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.27 STMI2 Introduction STMI2 (Subscriber Trunk Module IP) is a VoIP gateway board (VoIP - Voice over IP) which pro- vides the functionality of HG 1500 in HiPath 3800. This includes: Connection of a local LAN to the HiPath 3800 and connection with external LANs via the ●...
  • Page 372 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Extension modules The STMI2 board has two HGA (HiPath Gateway Accelerator) slots, which can be used to con- nect the extension modules. HGA- Slot 1 HGA- Slot 0 Figure 3-76 STMI2 (S30810-Q2316-X100) - HGA Slots Connections...
  • Page 373 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Front panel Two LEDs indicating the board status: Run (green) ● – on = at least 1 B channel busy – off = normal operation Fail (red) = error encountered ●...
  • Page 374 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards An additional shielding panel is not required on the front side of this board, because the EMC shield is already provided by the front panel. V.24 interface V.24 cable (C30267-Z355-A25) is used for connecting the service PC.
  • Page 375 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LAN interfaces Table 3-114 STMI2 - LAN Interface Assignment (RJ45 Jacks) Signal TDP (Transmit Data +) TDN (Transmit Data –) RDP (Receive Data +) TT1 (Transmit Termination 1) TT2 (Transmit Termination 2) RDN (Receive Data –) RT1 (Receive Termination 1)
  • Page 376: And Tcasr-2 (For Selected Countries Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.28 TCAS-2 and TCASR-2 (for selected countries only) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 377 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Figure 3-78 TCAS-2 (S30810-Q2945-X) (for selected countries only) – Figure Interfaces and Jumpers Modem (optional) CAS interface 1: X910 X909 3 2 1 X805: Analog modem CAS interface 2: X911 X912 X803: V.24 interface...
  • Page 378 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Settings Table 3-115 TCAS-2, TCASR-2 (for selected countries only) – Jumper Functions Jumper Function Setting Pins 1–2 closed Pins 2–3 closed Sets the V.24 baud rate See Table 3-116 Deletes the flash mem- Flash memory is deleted Flash memory is not de-...
  • Page 379 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Connections X910 (MINI BNC connector, 75 ohms): Receive (RX) CAS interface 1: X909 (MINI BNC connector, 75 ohms): Transmit (TX) X805 (RJ45 jack): Analog modem (optional) X911 (MINI BNC connector, 75 ohms): Receive (RX) CAS interface 2: X912 (MINI BNC connector, 75 ohms): Transmit (TX) X803 (9-pin MINI DIN jack): V.24 interface...
  • Page 380 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards TCASR-2 front panel Line 1 MODEM Line 2 V.24 ETHERNET Figure 3-81 TCASR-2 (for selected countries only) – Front Panel Seven-segment display The card’s software status can be ascertained on the basis of the seven-segment display. For this a distinction is made between the following boot phases: Power supply unit switched on The decimal point is flashing to indicate that the U-...
  • Page 381 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards U-boot (firmware) states ● Table 3-117 TCAS-2, TCASR-2 (for selected countries only) – U-boot (firmware) States Display Meaning Initializing hardware Downloading DSP (Digital Signal Processor) firmware Downloading FPGA (Field Programmable Gate Array) firmware Accessing flash EPROM (Save and Delete) Activating built-in self test BIST (BIST1 or BIST2) Administration (Service PC connected)
  • Page 382 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-118 TCAS-2, TCASR-2 (for selected countries only) – Linux Operating System States Display Meaning Mounting flash file system Error mounting flash (flashing display) Configuring network interface Loading real-time kernel modules Loading board-specific modules Core files available CAS application software states...
  • Page 383 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Modem (optional) X21: Pin1 Figure 3-83 TCAS-2, TCASR-2 (for selected countries only) – Optional Modem The analog modem (modem kit F31505-E1-A147) is an optional submodule for the TCAS-2 and TCASR-2 cards, which is plugged into the X20 and X21 ports.
  • Page 384 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Administration of the CAS protocol converter A separate tool, the CAS Manager, is used to download the software and administer the TCAS- 2 and TCASR-2. The CAS Manager software is stored on a CD supplied with the card. For in- formation on how to install the CAS Manager software on the Service PC, refer to the readme file.
  • Page 385 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards RJ45 Cable C39195-Z7208-A10 (included in modem kit F31505-E1-A147) HiPath 3500 ● Plug the RJ45 connector into TCASR-2: X805 the free jack on an analog sub- scriber line module. HiPath 3550 ●...
  • Page 386 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Assigning the CAS cable The following options are available for connecting network terminators (NT), multiplexers (MUX) or modems to the TCAS-2 and TCASR-2 cards (MINI BNC connections): Coaxial trunk (75 ohms), length = 10 m ●...
  • Page 387 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Figure 3-87 TCAS-2, TCASR-2 (for selected countries only) – Impedance Converter F31505-E1-A146 CAS cable shield contacts ● To ensure sufficient electromagnetic shielding (according to EN 55022), both shielded CAS cables must be contacted at the appropriate points on the HiPath 3550/HiPath 3350.
  • Page 388 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Figure 3-88 CAS cable – shield contacts A31003-H3590-S100-7-7620, 06/2012 3-256 HiPath 3000/5000 V9, Service documentation...
  • Page 389: Tla2 (Not For U.s.), Tla4 (Not For U.s.), Tla8 (Not For U.s.)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.29 TLA2 (Not for U.S.), TLA4 (Not for U.S.), TLA8 (not for U.S.) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 390 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-120 TLA2, TLA4 (not for U.S.) - Contact Assignments Contact Connector X2 Connector X4 Call charging module assignment (GMZ) Not for TLA2 A31003-H3590-S100-7-7620, 06/2012 3-258 HiPath 3000/5000 V9, Service documentation...
  • Page 391 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards The MSI board TLA8 with eight analog trunks for DP and DTMF signaling in HiPath 3550 and HiPath 3350. To GEE module T/R ports MSI 1 - 4 TLA8 to trunk To CUP/CUC...
  • Page 392: Tla4R (Not For U.s.)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.30 TLA4R (not for U.S.) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 393 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-122 TLA4R (not for U.S.) - Contact Assignments MW8 jack X5, pin Trunk connections 1-4 a trunk 1 b trunk 1 a trunk 2 b trunk 2 a trunk 3 b trunk 3 a trunk 4...
  • Page 394: Tm2Lp

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.31 TM2LP NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 395 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Table 3-123 TM2LP - LED Statuses Red LED Green Status Action Board not receiving power or not plugged in Check plug contact on correctly.
  • Page 396 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-124 TM2LP - SIVAPAC Connector Assignment on the Backplane a-wire b-wire Pair SIVAPAC connector TM2LP MDFU-E Notes (tip) (ring)1 wht/blu Port 1 blu/wht wht/ora Port 2 ora/wht wht/grn Port 3 grn/wht...
  • Page 397 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards see “Abbreviations for colors“ at the start of Section 3.3. A31003-H3590-S100-7-7620, 06/2012 3-265 HiPath 3000/5000 V9, Service documentation...
  • Page 398 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-125 TM2LP - Connector Panel Assignment with RJ45 Jacks RJ45 jack TM2LP Notes Free Free Free Free Free Free Free Free A31003-H3590-S100-7-7620, 06/2012 3-266 HiPath 3000/5000 V9, Service documentation...
  • Page 399 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-125 TM2LP - Connector Panel Assignment with RJ45 Jacks RJ45 jack TM2LP Notes Free Free Free Free Free Free Free Free A31003-H3590-S100-7-7620, 06/2012 3-267 HiPath 3000/5000 V9, Service documentation...
  • Page 400 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-126 TM2LP - Connector Panel Assignment with CHAMP Jack (for U.S. only) CHAMP jack TM2LP Notes 1 Ring Port 1 1 TIP 2 Ring Port 2 2 TIP 3 Ring Port 3 3 TIP...
  • Page 401 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-127 TM2LP - Connector Panel Assignment with SIPAC 1 SU Connectors (Cable for Ports 1 - 16) Color a-wire b-wire SU con- Patch Panel, Pair TM2LP MDFU-E Notes Group (tip)
  • Page 402: Tmamf (For Selected Countries Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.32 TMAMF (for selected countries only) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 403 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Notes on DSP diagnosis You can use the trace function built into the TMAMF module to diagnose malfunctions or obtain more precise error analysis. The subminiature D connector provides information about MFC- R2 signaling.
  • Page 404 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings H100 LED (see Figure 3-93): signal processor status ● Table 3-128 TMAMF - LED Statuses (H100) LED status Meaning Action (on/off) During Startup and Initialization –...
  • Page 405 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Cable and connector assignment (backplane, MDFU/MDFU-E, patch panel) Table 3-130 TMAMF - Cable Assignment SU con- Color a-wire b-wire MDFU/ Patch Panel, nector Pair TMAMF Notes Group (tip) (ring)1 MDFU-E MW8 pin...
  • Page 406: Tlani2, Tlani4, Tlani8

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.33 TLANI2, TLANI4, TLANI8 NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 407 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Interfaces X106 X105 T/R ports 1 2 3 1 2 3 MSI 1 - 4 (LS 3, 4 not Jumper for TLANI2) to CUP/ X3 (free) ALUM 1, 2 TLANI2, TLANI4 Figure 3-95 TLANI2, TLANI4 - Interfaces (S30810-H2953-X1xx / -Xxx)
  • Page 408 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards – Loop start setting = pins 3–4 closed (default) – Ground start setting = pins 1–2 closed [ground start not possible for TLANI8-IM and TLANI8-BRA] Contact assignments Table 3-131 TLANI2, TLANI4 - Contact Assignments Contact Connector X2...
  • Page 409: Tlani4R

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.34 TLANI4R NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 410 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Interfaces X106 X105 MSI 1 1 2 3 1 2 3 Jumper MSI 4 to CUPR/ 8 MW8 CUCR jacks ALUM 1 + 2 TLANI4R Figure 3-97 TLANI4R - Interfaces (S30810-K2953-X2xx) Contact assignments Table 3-133 TLANI4R - Contact Assignments...
  • Page 411 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-133 TLANI4R - Contact Assignments MW8 jack X5, pin ALUM 1 + 2 ALUM1: Subsc. line module connection ALUM2: Subsc. line module connection ALUM1: Analog telephone connection ALUM2: Analog telephone connection Jumper for setting the procedure for analog trunk interfaces Process settings for the analog trunk interface is via X105 and X106 jumpers.
  • Page 412: Tmani, Tmani-Im, Tmani-Bra [Tmani8]

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.35 TMANI, TMANI-IM, TMANI-BRA [TMANI8] NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 413 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards “Silent Reversal”, which is used to register the beginning and end of an outgoing call in dif- ferent countries, is also supported. It can be activated with HiPath 3000/5000 Manager E (Settings menu: Lines/networking ...
  • Page 414 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Jumper for setting the procedure for analog trunk interfaces The procedure for the analog trunk interfaces is set via jumper X100 and X101. Loop start setting = pins 1–2 closed (default) ●...
  • Page 415 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-135 TMANI8 - SIVAPAC Connector Assignment on the Backplane a-wire b-wire Pair SIVAPAC connector TMANI8 MDFU-E Notes (tip) (ring)1 wht/blu Port 1 blu/wht wht/ora Port 2 ora/wht wht/grn Port 3 grn/wht...
  • Page 416 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-136 TMANI8 - Connector Panel Assignment with RJ45 Jacks RJ45 jack TMANI8 Notes Free Free Free Free Free Free Free Free Free A31003-H3590-S100-7-7620, 06/2012 3-284 HiPath 3000/5000 V9, Service documentation...
  • Page 417 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-136 TMANI8 - Connector Panel Assignment with RJ45 Jacks RJ45 jack TMANI8 Notes Free Free Free Free Free Free Free A31003-H3590-S100-7-7620, 06/2012 3-285 HiPath 3000/5000 V9, Service documentation...
  • Page 418 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-137 TMANI8 - Connector Panel Assignment with CHAMP Jack (for U.S. only) CHAMP jack TMANI8 Notes 1 Ring Port 1 1 TIP 2 Ring Port 2 2 TIP 3 Ring Port 3 3 TIP...
  • Page 419 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-138 TMANI8 - Connector Panel Assignment with SIPAC 1 SU Connectors (Cable for Ports 1 - 16) Color a-wire b-wire SU con- Patch Panel, Pair TMANI8 MDFU-E Notes Group (tip)
  • Page 420: Tmc16 (For Selected Countries Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.36 TMC16 (for selected countries only) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 421 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Table 3-139 TMC16 (for selected countries only) - LED Statuses Red LED Green Status Action Board not receiving power or not plugged in Check plug contact on correctly.
  • Page 422 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-140 TMC16 (for selected countries only) - SIVAPAC Connector Assignment on the Backplane a-wire b-wire Pair SIVAPAC connector TMC16 MDFU-E Notes (tip) (ring)1 wht/blu Port 1 blu/wht wht/ora Port 2 ora/wht...
  • Page 423 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards see “Abbreviations for colors“ at the start of Section 3.3. A31003-H3590-S100-7-7620, 06/2012 3-291 HiPath 3000/5000 V9, Service documentation...
  • Page 424 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-141 TMC16 (for selected countries only) - Connector Panel Assignment with CHAMP Jack CHAMP jack TMC16 Notes 1 Ring Port 1 1 TIP 2 Ring Port 2 2 TIP 3 Ring Port 3...
  • Page 425 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-142 TMC16 (for selected countries only) - Connector Panel Assignment with SIPAC 1 SU Connectors (Cable for Ports 1 - 16) Color a-wire b-wire SU con- Patch Panel, Pair TMC16 MDFU-E...
  • Page 426: Tmcas (For Selected Countries Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.37 TMCAS (for selected countries only) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 427 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Switches and display Display 25-pin SUB-D jack: V24 interface for connecting the service PC with the ECGM tool Battery Lockout switch (position = free, factory default) Switch S4 = default Jumper 3 2 1...
  • Page 428 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 100 ohms 75 ohms No function Impedance on the S Side Switches S4-3 S4-4 120 ohms (default) 100 ohms 75 ohms No function Switches S4-5 to S4-8 Switches Function S4-5 Reserved...
  • Page 429 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Jumpers S2 and S3 for GND connection You can set the GND connection (signal ground) of the receiving (Rx) and transmitting (Tx) lines on the CAS side here. GND connection Jumper setting no signal ground (default)
  • Page 430 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Seven-segment display H1 The board statuses listed in the following table are displayed on H1. Table 3-143 TMCAS - Seven-Segment Display H1 Display Meaning Waiting for the TMCAS software download TMCAS software download start TMCAS software download Writing the TMCAS software/extender software into the flash memory...
  • Page 431 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-144 Assignment of the TMCAS Cable C39195-A9700-B512 SU connector Xx8, pin Function Color code a-wire (T), transmit b-wire (R), transmit coaxial line (75 ohms) ● Table 3-145 Assignment of the TMCAS Cable C39195-A9700-B514 SU connector Xx8, pin Function...
  • Page 432 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Procedure for retrofitting a TMCAS board Step Activity Disconnect system from power supply and open system. Insert TS2N (HiPath 3550). HiPath 3550 (wall housing): Insert TMCAS in slot 10. Plug in TMS2/TS2N-TMCAS connection cable.
  • Page 433 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Installing the ECGM tool and configuring the CAS protocol converter This section describes how to install the ECGM tool on the service PC and configure the CAS protocol converter on the TMCAS board. The ECGM tool supports the following actions: Extender, database and software download ●...
  • Page 434 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Step Activity Make the following settings in the ECGM tool: File/Options menu: Select the service PC’s COM interface (for example: ● COM1) File/Install Software menu: Select the file E1v0xx.pnm (for exam- ●...
  • Page 435: Tmcas-2 (For Selected Countries Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.38 TMCAS-2 (for selected countries only) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 436 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Figure 3-101 TMCAS-2 (S30810-Q2946-X) (for selected countries only) – Figure A31003-H3590-S100-7-7620, 06/2012 3-304 HiPath 3000/5000 V9, Service documentation...
  • Page 437 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Interfaces and Jumpers Modem (optional) 3 2 1 X909: CAS inter- 1 2 3 face 1 X999 X910: CAS inter- face 2 1 2 3 3 2 1 X803: V.24 inter- face X804: Ethernet (10/...
  • Page 438 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Settings Table 3-146 TMCAS-2 (for selected countries only) – Jumper Functions Jumper Function Setting Pins 1–2 closed Pins 2–3 closed Sets the V.24 baud rate See Table 3-147 Deletes the flash mem- Flash memory is deleted Flash memory is not de-...
  • Page 439 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Front panel Seven-segment display X909 (15-pin Sub-D jack): CAS interface 1 X910 (15-pin Sub-D jack): CAS interface 2 X803 (9-pin MINI DIN jack): V.24 interface X804 (RJ45 jack): Ethernet (10/100BaseT) interface Two LEDs indicate the current interface status: Yellow LED = transmitting data ●...
  • Page 440 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Seven-segment display The card’s software status can be ascertained on the basis of the seven-segment display. For this a distinction is made between the following boot phases: Power supply unit switched on The decimal point is flashing to indicate that the U- U-boot U-boot...
  • Page 441 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-148 TMCAS-2 (for selected countries only) – U-boot (firmware) States Display Meaning Downloading image file (Linux and CAS application) Initializing the Linux operating system Error Resetting the card U-boot (firmware) operational (decimal point flashing) Linux operating system states ●...
  • Page 442 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards CAS application software states ● Interface 1 (ISDN) active Interface 1 (CAS) active Interface 2 (ISDN) active Interface 2 (CAS) active CAS application operational (flashing display) Figure 3-104 TMCAS-2 (for selected countries only) –...
  • Page 443 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Administration of the CAS protocol converter A separate tool, the CAS Manager, is used to download the software and administer the TM- CAS-2. The CAS Manager software is stored on a CD supplied with the card. For information on how to install the CAS Manager software on the Service PC, refer to the readme file.
  • Page 444 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Assigning both CAS cables You can use one of the following two cables to connect network terminators (NT), multiplexers (MUX), or modems to the TMCAS-2 card (15-pin sub-D jacks X909 and X910): symmetrical line (120 ohms), length = 10 m ●...
  • Page 445: Tmdid (For U.s. Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.39 TMDID (for U.S. only) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 446 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Front panel LEDs (green) for displaying the trunk status: Trunk circuit 0 ● Trunk circuit 1 ● Trunk circuit 2 ● Trunk circuit 3 ● Trunk circuit 4 ●...
  • Page 447 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-153 TMDID (for U.S. only) - SIVAPAC Connector Assignment on the Backplane a-wire b-wire Pair SIVAPAC connector TMDID MDFU-E Notes (tip) (ring)1 wht/blu Port 1 blu/wht wht/ora Port 2 ora/wht wht/grn...
  • Page 448 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-154 TMDID (for U.S. only) - Connector Panel Assignment with CHAMP Jack CHAMP jack TMDID Notes 1 Ring Port 1 1 TIP 2 Ring Port 2 2 TIP 3 Ring Port 3 3 TIP...
  • Page 449 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-155 TMDID (for U.S. only) - Connector Panel Assignment with SIPAC1SU Connec- tors (Cable for Ports 1 - 16) Color a-wire b-wire SU con- Patch Panel, Pair TMDID MDFU-E Notes...
  • Page 450: Tmdid2 (For Selected Countries Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.40 TMDID2 (for selected countries only) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 451 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Front panel Two LEDs indicating the board status: LED (red) ● LED (green) ● Figure 3-110 TMDID2 (for selected countries only) - LEDs on the Front Panel To ensure sufficient shielding, provide the board with a shielding panel. For informa- >...
  • Page 452 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Table 3-156 TMDID2 (for selected countries only) - LED Statuses Red LED Green Status Action Board not receiving power or not plugged in Check plug contact on correctly.
  • Page 453 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-157 TMDID2 (for selected countries only) - SIVAPAC Connector Assignment on the Backplane a-wire b-wire Pair SIVAPAC connector TMDID2 MDFU-E Notes (tip) (ring)1 wht/blu Port 1 blu/wht wht/ora Port 2 ora/wht...
  • Page 454 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards see “Abbreviations for colors“ at the start of Section 3.3. A31003-H3590-S100-7-7620, 06/2012 3-322 HiPath 3000/5000 V9, Service documentation...
  • Page 455 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-158 TMDID2 (for selected countries only) - Connector Panel Assignment with RJ45 Jacks RJ45 jack TMDID2 Notes Free Free Free Free Free Free Free Free A31003-H3590-S100-7-7620, 06/2012 3-323 HiPath 3000/5000 V9, Service documentation...
  • Page 456 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-158 TMDID2 (for selected countries only) - Connector Panel Assignment with RJ45 Jacks RJ45 jack TMDID2 Notes Free Free Free Free Free Free Free Free A31003-H3590-S100-7-7620, 06/2012 3-324 HiPath 3000/5000 V9, Service documentation...
  • Page 457 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-159 TMDID2 (for selected countries only) - Connector Panel Assignment with CHAMP Jacks (for U.S. only) CHAMP jack TMDID2 Notes 1 Ring Port 1 1 TIP 2 Ring Port 2 2 TIP 3 Ring...
  • Page 458 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-160 TMDID2 (for selected countries only) - Connector Panel Assignment with SI- PAC 1 SU Connectors (Cable for ports 1-16) Color a-wire b-wire SU con- Patch Panel, Pair TMDID2 MDFU-E...
  • Page 459: Tmew2

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.41 TMEW2 NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 460 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Signaling paths E&M trunks are used for signaling between networked communications systems: E-wire = ear (receive), M-wire = mouth (transmit). Protocol settings TMEW2 supports interface types 1A and 5. Interface types 1A and 5 are identical. Before starting up the tie trunk, you must ensure that the two participating systems support the specified interface types.
  • Page 461 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards HiPath 3000/5000 Manager E is used to set the signaling protocol. Settings Menu: Lines/net- working ... –> Trunks –> (double-click) Parameters –> Template Editor: Board type = TMDID, TIEL, TMEW2 ●...
  • Page 462 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Front panel Two LEDs indicating the board status: LED (red) ● LED (green) ● Figure 3-113 TMEW2 - Front Panel (S30810-Q2292-X100) To ensure sufficient shielding, provide the board with a shielding panel. For informa- >...
  • Page 463 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards LED statuses and their meanings Table 3-161 TMEW2 - LED Statuses Red LED Green Status Action Board not receiving power or not plugged in Check plug contact on correctly.
  • Page 464 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-162 TMEW2 - SIVAPAC Connector Assignment on the Backplane in Tie Trunk Traf- fic via Interface Type 1A (or 5) a-wire b-wire Pair SIVAPAC connector TMEW2 MDFU-E Notes (tip) (ring)1...
  • Page 465 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-163 TMEW2 - SIVAPAC Connector Assignment on the Backplane with Genius An- nouncement Device Connected (Interface Type 2): a-wire b-wire Pair SIVAPAC connector TMEW2 MDFU-E Notes (tip) (ring)1 wht/blu Ring...
  • Page 466: Tmgl4 (For U.s. Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.42 TMGL4 (for U.S. only) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 467 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Contact assignment Table 3-164 TMGL4 (for U.S. only) - Contact Assignment Contact Connector X2 Port b-wire (ring), trunk 1 a-wire (tip), trunk 1 b-wire (ring), trunk 2 a-wire (tip), trunk 2 b-wire (ring), trunk 3 a-wire (tip), trunk 3 b-wire (ring), trunk 4...
  • Page 468: Tmgl4R (For U.s. Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.43 TMGL4R (for U.S. only) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 469 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Contact assignment Table 3-165 TMGL4R (for U.S. only) - Contact Assignment Port X3 Pin X4 Pin X5 Pin Signal (To GEE) (To trunks 1-4) (To ANI4R) b-wire (ring), trunk 1 a-wire (tip), trunk 1 b-wire (ring), trunk 2 a-wire (tip), trunk 2...
  • Page 470: Tmq4 (For U.s. Only)

    Q interface. The interface supports the following central office protocols: AT&T 5Ess NI-1 ● AT&T 5ESS Custom ● Nortel DMS100 NI-1 ● Siemens EWSD NI-1 ● Interfaces To CUP/ TMQ4 board To trunks Figure 3-116 TMQ4 (for U.S. only) (S30810-Q2917-X)
  • Page 471 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Contact assignment Table 3-166 TMQ4 (for U.S. only) - Contact Assignment Contact Connector X2 Port Contact Connector X2 Port b-wire (ring), trunk 1 b-wire (ring), trunk 3 a-wire (tip), trunk 1 a-wire (tip), trunk 3 b-wire (ring), trunk 2 b-wire (ring), trunk 4...
  • Page 472: Tst1 (For U.s. Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.45 TST1 (for U.S. only) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 473 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Interfaces To CO To CUC/ TST1 CUCR Figure 3-117 TST1 (for U.S. only) (S30810-Q2919-X/S30810-K2919-Z) A31003-H3590-S100-7-7620, 06/2012 3-341 HiPath 3000/5000 V9, Service documentation...
  • Page 474 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Contact assignment Table 3-167 TST1 (for U.S. only) - Contact Assignment Contact Contact b-wire (ring), receive a-wire (tip), transmit a-wire (tip), receive not connected not connected not connected b-wire (ring), transmit not connected A31003-H3590-S100-7-7620, 06/2012...
  • Page 475: Ts2N (Old: Ts2) [Not For U.s.], Ts2R (Not For U.s.)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.46 TS2N (old: TS2) [Not for U.S.], TS2R (not for U.S.) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 476 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards with each ECG cabinet, for information on the connection and power supply. For HiPath 3000 V1.0 and later, you can also use the new TMCAS board to support country- specific CAS protocols.
  • Page 477 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Network interfaces The TS2N board is connected to the network transfer point (NT1) via the symmetrical line (120 ohms, four-wire twisted-pair cable) at X2 or via an MW line at X5. Note: use the connection kits listed on Page 3-347 for NT connections in Spain and Portugal.
  • Page 478 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards trunk connection HiPath 3550, HiPath 3500 Public network TS2N/TS2R Figure 3-120 trunk connection Keep the cable from the NT to HiPath 3550 or HiPath 3500 as short as possible to ensure prop- er operation.
  • Page 479 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Cable set for NT connections (Spain and Portugal only) Spain (and in certain cases Portugal) Public network HiPath 3550, HiPath 3500 Cable 1 Interface TS2N/TS2R Cable 2 converter Portugal Public network HiPath 3550, HiPath 3500...
  • Page 480: 4Sla (Not For U.s.), 8Sla, 16Sla (Not For U.s.)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.47 4SLA (not for U.S.), 8SLA, 16SLA (Not for U.S.) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 481 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-170 4SLA (not for U.S.), 8SLA Contact Assignments Contact X2 (T/R ports 1 to 4) X3 (T/R ports 5 to 8) T/R ports Stns. 1 to 4 T/R ports To CUP/ Stns.
  • Page 482 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards The operating mode (short or long line with the appropriate flash times) can be set up for each subscriber line interface with HiPath 3000/5000 Manager E (the menu settings: Set up station –>...
  • Page 483: 8Slar

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards 3.3.48 8SLAR NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 484 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Peripheral boards Table 3-172 8SLAR Contact Assignments RJ45 jack X2, Pin T/R ports 1-4 MW8 jack X2, Pin T/R ports 5-8 Technical connection conditions Maximum supply current: approximately 34 mA; maximum supply voltage: approximately ●...
  • Page 485: Options

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Options Abbreviations for colors The tables in this section use abbreviations to denote the colors of connector assignments. The abbreviations used are as follows: wh: white rd: red bn: brown ●...
  • Page 486: Alum4

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options 3.4.1 ALUM4 NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 487 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Interfaces CB side from the CO ALUM module to the tele- Board side Figure 3-126 ALUM4 - Interfaces (S30817-Q935-A) The cable that is plugged in by default is split and is connected to the TLA and to the >...
  • Page 488 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Table 3-173 ALUM4 - Interface Assignments (not for U.S.) Contact Connector X3 Connector X4 Connector X6 – – TA2 to SLA* a – – TB2 to SLA* b – –...
  • Page 489 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options ALUM module block diagram Trunk Connector HiPath 3550 HiPath 3350 ALUM Relay Connector X6 K1-B K2-B BT1 (T1) Trunk board AT1 (R1) Subscriber line module K1-C K2-C Relay Connector Analog telephone Figure 3-127 ALUM4 - Basic Structure...
  • Page 490: Amom

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options 3.4.2 AMOM Introduction AMOM is an opto-electronic converter that can be used to connect fiber optic cables to the Sub- D jacks on the front panel of the DIU2U, DIUN2, and DIUT2 boards.
  • Page 491 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Connector assignment Table 3-175 AMOM - 15-Pin Sub-D Plug Assignment Signal Signal description Direction LWLO0_FRONT Data output on the optical fiber in- Input terface Ground return path for the +5-V Input/output power supply SCAN_IN0...
  • Page 492: Ani4 (For Selected Countries Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options 3.4.3 ANI4 (for selected countries only) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 493 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options If ANI4 is properly detected by the system, the green LED is reset (after the initialization of all system software) and the bottom line of the display on the optiPoint 500 phones appears. This means that the ANI4 has received system software activation for all four channels.
  • Page 494 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Table 3-176 ANI4 (for selected countries only) - LED Statuses for Trunk 1 Meaning Action Red LED - Checksum Status The received caller ID signal has a checksum error. If the red LED is on after ev- The LED is reset after the next correct caller ID mes- ery call: the FSK signal is...
  • Page 495 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options ANI4 installation instructions Follow the steps below to install ANI4 in the HiPath 3550 or HiPath 3350 system. Caution Remove the trunk slip-on connectors from the TMGL4 board before starting to work on the system.
  • Page 496: Ani4R (For Selected Countries Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options 3.4.4 ANI4R (for selected countries only) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 497 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Contact assignment Table 3-178 ANI4R (for selected countries only) - Contact Assignment X3 Pin Signal X3 Pin Signal – a-wire (tip), trunk 3 a-wire (tip), trunk 1 b-wire (ring), trunk 3 b-wire (ring), trunk 1 a-wire (tip), trunk 4 a-wire (tip), trunk 2...
  • Page 498: Announcement And Music Modules

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options 3.4.5 Announcement and Music Modules Caution Place the central control board on a flat surface before inserting a subboard. Other- wise you may damage the board. Introduction The HiPath 3000 systems use different modules or boards for playing announcements and mu- sic on hold.
  • Page 499 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Table 3-179 Announcement and Music Modules Module / Board Part number UAM (not for U.S.) S30122-X7217-X Used in HiPath 3550 and HiPath 3350 (wall hous- ● ing). Connected to OPAL and T/R interface (for the an- ●...
  • Page 500 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Slot for EXM Cable duct Slot for EXM module Figure 3-132 EXM Slot for HiPath 3550 and HiPath 3350 Wall Housing Connection of EXMR EXMR Direct (component side) connection of the ex- ternal music source Note: A cable binder has been provided in the cable duct for suitable strain relief of the connecting cable.
  • Page 501 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Installing the EXMR S30122-K7403-T on the CBRC S30810-K2935-Z401 The installation of the EXMR on the CBRC is described in Section 4.2.4.13, “Installing the EXMR on the CBRC”. A31003-H3590-S100-7-7620, 06/2012 3-369 HiPath 3000/5000 V9, Service documentation...
  • Page 502: Evm

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options 3.4.6 Introduction The optional EVM (Entry Voice Mail) subboard enables the function of integrated voice mail in HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300. The prerequisite for this is the use of the S30810-Q2935-A301/-A401 (CBCC) and S30810-Q2935-Z301/-Z401 (CBRC) central boards.
  • Page 503 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Interfaces Spacing bolts 26-pin socket strip X1 (not used for HiPath 3000) Figure 3-135 EVM (S30807-Q6945-X) - Interfaces Individual announcements in the case of upgrades In the case of a Fast Upgrade, i.e., within a release, the individual announcements and mes- sages are retained.
  • Page 504: Exmna (For U.s. Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options 3.4.7 EXMNA (for U.S. only) Introduction The EXMNA (external music on hold) module provides a connection for external music on hold in HiPath 3550 and HiPath 3350. The EXMNA connects to the CBCC and CBCP board (connector X4) by means of a ribbon ca- ble.
  • Page 505 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Contact assignment Table 3-180 EXMNA (for U.S. only) - Contact Assignments Contact Connector X1 Connector X2 Input Not assigned Input Not assigned Not assigned EXMCL Not assigned EXMDIR HRES EXMD EXMDET +5 V...
  • Page 506: Gee12 (Not For U.s.), Gee16 (Not For U.s.), Gee50 (Not For U.s.)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options 3.4.8 GEE12 (not for U.S.), GEE16 (not for U.S.), GEE50 (not for U.S.) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 507 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Contact assignments Table 3-182 GEE12, GEE16, GEE50 (not for U.S.) - Contact Assignments Contact Connector X3 Connector Connector GND * CO 1 (AL1) CO 1 (BN 1) CO 1 (BL1) CO 1 (AN 1) CO 2 (AL2) CO 2 (BN 2)
  • Page 508: Hope (For U.s. Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options 3.4.9 HOPE (for U.S. only) Introduction The HOPE (Hicom Office PhoneMail Entry) board provides Hicom Office PhoneMail Entry func- tions. The HOPE board does not identify itself to the system and is therefore not visible in >...
  • Page 509 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options The on/off switch turns the Office PhoneMail system on and off ● The PCMCIA slot is for Office PhoneMail software cards (for example, voice cards). ● The card ejector ejects the software cards from the PMCIA slot ●...
  • Page 510: Opal And Opalr

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options 3.4.10 OPAL and OPALR Introduction The adapter cable for connecting the central board to the first optional board comes in two ver- sions: OPAL (Options Adapter Cable Long) C39195-A7001-B130 (Figure 3-140 - for use in Hi- ●...
  • Page 511 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options OPALR interface Option board connection CBRC interface Figure 3-141 OPALR (C39195-A7001-B142) A31003-H3590-S100-7-7620, 06/2012 3-379 HiPath 3000/5000 V9, Service documentation...
  • Page 512: Pft1 (Not For U.s.), Pft4 (Not For U.s.)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options 3.4.11 PFT1 (not for U.S.), PFT4 (not for U.S.) Introduction In the event of a power failure or system error in HiPath 3800, analog trunks can be transferred (ALUM) to designated analog telephones. These are: 1 analog trunk with a PFT1 (Power Failure Tranfer) board ●...
  • Page 513 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Installation location of the PFT1 and PFT4 board (MDFU/MDFU-E) Wire PFT1 or PFT4 into the MDFU or MDFU-E. The boards require -48 V. For the assignments of both boards, see Figure 3-144. 2 x PFT1 1 x PFT4 System side...
  • Page 514 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options PFT1 and PFT4 board assignment PFT4 - 48 PFT1 TMA, TMB = Trunk circuit A, B = a, b (Telephone company) SMA, SMB = SLA board SLA, SLB = Analog telephone - 48 Figure 3-144 PFT1 (S30777-Q539-X) and PFT4 (S30777-Q540-X) Board Assignment...
  • Page 515: Reals

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options 3.4.12 REALS NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 516 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Two -48-V lines fused using a PTC resistor are available for external applications. The voltage is picked up by the MDFU-E (Table 3-183: M48VF1 / 0V_F and M48VF2 / 0V_F). Each trunk has a maximum load capacity of 300 mA.
  • Page 517 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Slot Insert the REALS board into the slot marked 3 in the lower part of the shelf in the basic cabinet and apply pressure until you hear a click (see Figure 4-21). The slots for the power supply units and for the REALS board must be covered with an outer panel before the system is started up.
  • Page 518 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Table 3-183 REALS - SIVAPAC Connector Assignment on the Backplane a-wire b-wire SIVAPAC Connec- Pair REALS MDFU-E Notes (tip) (ring)1 tor X116 wht/blu M48VF1 – 48 V (max. 300 mA) blu/wht 0V_F wht/ora...
  • Page 519 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Table 3-183 REALS - SIVAPAC Connector Assignment on the Backplane a-wire b-wire SIVAPAC Connec- Pair REALS MDFU-E Notes (tip) (ring)1 tor X116 blk/gry gry/blk yel/blu PFTTSb ALUM: Subscriber line module blu/yel PFTTSa...
  • Page 520: Stbg4 (For France Only)

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options 3.4.13 STBG4 (for France only) NOTE > Danger of damage to property due to surge voltage. The required lightning protec- tion measures must be taken for this board, see Section 2.1.2, “Lightning Protec- tion”.
  • Page 521 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options Table 3-184 STBG4 (for France only) - Contact Assignment Contact Connector X3 Connector X4 On 4 – Not used – A31003-H3590-S100-7-7620, 06/2012 3-389 HiPath 3000/5000 V9, Service documentation...
  • Page 522: Strb, Strbr

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options 3.4.14 STRB, STRBR Introduction This option comes in two versions: STRB (Control Relay Board) S30817-Q932-A (Figure 3-148) - for use in HiPath 3550 and ● HiPath 3350 (wall housing) STRBR (Control Relay Board Rack) S30817-K932-Z (Figure 3-149) - for use in HiPath ●...
  • Page 523 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options STRB interfaces CBCC/CBCP side STRB Board side Figure 3-148 STRB Interfaces (S30817-Q932-A) STRBR interfaces CBRC side 8-pin MW8 jacks STRBR Board side Figure 3-149 STRBR Interfaces (S30817-Q932-Z) Control relay connection values Warning The STRB or STRBR interface is an SELV (Safety Extra-Low Voltage Circuit) inter- face, as defined by IEC 60950.
  • Page 524 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options STRB and STRBR Board Relay and Sensor Functions STRB or STRBR K1.21 K1.22 K1.23 Relay K1.11 K1.12 K1.13 +12 V +12 VI Short the wires to activate the sensor. OPTKP1 Sensor To system...
  • Page 525 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options STRB contact assignment Table 3-185 STRB Contact Assignments Connector Contact Signal Name Function K 4.21 Relay contact K4.2 (common) K 4.22 Relay contact K4.2 (NO) K 4.23 Relay contact K4.2 (NC) K 3.21 Relay contact K3.2 (common) K 3.22...
  • Page 526 boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options STRBR contact assignments Table 3-186 STRBR Contact Assignments X3, Pin Signal Name Function ACT4-2M Relay contact K203 (common) 2 ACT4-2B Relay contact K203 (NO) 2 ACT4-2A Relay contact K203 (NC) 2 ACT4-1M Relay contact K203 (common) 1 ACT4-1B...
  • Page 527: Usb V.24 Adapter

    boards.fm Boards for HiPath 3000 Nur für den internen Gebrauch Options 3.4.15 USB V.24 Adapter The following adapters have been tested for connecting serial devices to the USB interface on the service PC: Serial USB adapter F5U103 from Belkin Corporation (www.belkin.com) ●...