Table 3-55
SLA16N, SLA24N - Assignment (SU Xx8, Xx9) (for U.S. only)
a-wire
b-wire
#
1
(tip)
(ring)1
red/brn
17
brn/red
red/gry
18
gry/red
blk/blu
19
blu/blk
blk/ora
20
ora/blk
blk/grn
21
grn/blk
blk/brn
22
brn/blk
blk/gry
23
gry/blk
yel/blu
24
blu/yel
1
see "Abbreviations for colors" at the start of Section 3.3.
Technical connection conditions
Maximum supply current: approximately 34 mA; maximum supply voltage: approximately
40 V DC
Ring voltage against negative supply voltage (a-wire (tip)/RING): two telephones maxi-
mum
Range, see Section 2.7
Loop current detection > 10 mA
Ground button detection > 20 mA
The transmission technology is set according to the specific country through the respec-
tively entered country code (for country initialization, see Chapter 5, "Starting Up HiPath
3000").
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
SU connector
BP: Xx8
BP: Xx9
11
31
02
22
13
33
04
24
15
35
06
26
17
37
08
28
SLA16N, SLA24N
17a
Port 17
17b
18a
Port 18
18b
19a
Port 19
19b
20a
Port 20
20b
21a
Port 21
21b
22a
Port 22
22b
23a
Port 23
23b
24a
Port 24
24b
Boards for HiPath 3000
Peripheral boards
CHAMP jack, MDF
9
9a
34
9b
10
10a
35
10b
11
11a
36
11b
12
12a
37
12b
13
13a
38
13b
14
14a
39
14b
15
15a
40
15b
16
16a
41
16b
boards.fm
Notes
not
used
in
SLA16N