Introduction
From HiPath 3000/5000 V6 R4 and V7 R4 or higher the following boards can be used to con-
nect analog stations (analog telephones, fax group 3 etc.):
SLAD4 (Subscriber Line Analog with DuSLIC) S30810-H2956-X100 – for HiPath 3550 and
HiPath 3350
SLAD8 (Subscriber Line Analog with DuSLIC) S30810-H2956-X200 – for HiPath 3550 and
HiPath 3350
SLAD8R (Subscriber Line Analog with DuSLIC Rack) S30810-K2956-X300 - for
HiPath 3500 and HiPath 3300
The SLAD boards are compatible successor modules for the following boards:
4SLA (S30810-Q2923-X200)
8SLA (S30810-Q2923-X100)
8SLAR (S30810-K2925-Z).
These are being phased out and can no longer be ordered.
Main features
A DTMF code receiver is available for each analog interface (permits DTMF dialing at analog
telephones). This guarantees that all analog terminals connected are fully accessible.
These boards support calling name identification presentation (CLIP).
The connection of external extensions via OPS (Off-Premises Station) signaling is supported.
Ring voltage is generated by the power supply unit of the relevant system
and SLAD8,
UPSC-DR
the country-specific ring frequency.
3-130
for SLAD8R). Please refer to Section 2.8 for information on how to set