Siemens HiPath 3000 Series Service Documentation page 215

Table of Contents

Advertisement

Nur für den internen Gebrauch
LED statuses and their meanings
Table 3-30
DIU2U (for U.S. only) - LED Statuses
Red LED
Green
LED
Off
Off
On
Off
Flashing
Off
Off
On
Off
Flashing At least one channel is activated.
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Status
Board not receiving power or not plugged in
correctly.
Board is out of order.
Board is receiving power and board test is
in progress.
Board is defective if status remains un-
changed (board test unsuccessful).
Loadware loading not successfully com-
pleted. Board is faulty.
Error detected on board.
Board is deactivated (not applicable to er-
rors detected by test loops) or board was
deactivated using HiPath 3000/5000 Man-
ager E.
Loadware is being loaded.
Board test completed successfully. Board is
OK (idle state).
boards.fm
Boards for HiPath 3000
Peripheral boards
Action
Check plug contact on
board.
Replace board.
Replace board.
Check whether the board
was deactivated using Hi-
Path 3000/5000 Manager
E. If not, replace board.
3-83

Hide quick links:

Advertisement

Table of Contents
loading