DIU2U (for U.S. only)

Introduction
The DIU2U (Digital Interface Unit 2 Universal) trunk module connects two digital trunks to Hi-
Path 3800 and in this way provides two primary rate interfaces (PRI) ISDN via T1 interfaces.
Connection types
Fiber optic cable
The fiber optic cable is only connected via the front panel. The opto-electronic converter
AMOM
must be used to connect a fiber optic cable to the 15-pin Sub-D jacks on the front
panel.
Copper cable
The copper cable is connected to T1-CSU (Customer Service Unit) or DSU (Data Service
Unit) via the adapter cable (C39195-A7269-B625) shown in Figure 3-30.
Adapter cable C39195-A7269-B625
Figure 3-30
DIU2U (for U.S. only) Adapter Cable C39195-A7269-B625
Table 3-29
DIU2U (for U.S. only) - adapter cable assignment (C39195-A7269-B625)
15-pin Sub-D
connector
Pin
9
1
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
50-pin Amphenol con-
nector
Pin
38
13
Boards for HiPath 3000
Function
a-wire (T), transmit
b-wire (R), transmit
boards.fm
Peripheral boards
Color code
wht/blu
blu/wht
3-81