Nur für den internen Gebrauch
Definition of application and connection type
The board is configured via the loadware once the application and connection type have been
selected.
The application type is selected with HiPath 3000/5000 Manager E: System status – Sys-
tem-wide – SW expansion – Card selection
The following options are available:
DIUT2 T1 S2: for use as an S2M interface (S2M trunk connection, S2M network)
DIUT2 T1: for use as a T1 interface (T1-PRI trunk connection)
DIUT2 T1 analog: for use as a T1 interface for T1 analog (T1 analog trunk connection)
The connection type is selected with HiPath 3000/5000 Manager E: System status – Sys-
tem-wide – SW expansion – Card data.
The following options are available:
DIUT2 T1 S2 mod., DIUT2 T1 mod., DIUT2 T1 analog mod.: for connection via fiber
optic cable
The fiber optic cable is only connected via the front panel. The opto-electronic convert-
er
AMOM
must be used to connect a fiber optic cable to the 15-pin Sub-D jacks on the
front panel.
DIUT2 T1 S2, DIUT2 T1, DIUT2 T1 analog: for connection via copper cable (system
cable S30267-Z167-Axxx)
The copper cable is only connected via the 15-pin Sub-D jacks on the front panel.
The connection type setting always applies to both interfaces in a board. Different connection
types cannot be used at the same time.
Both interfaces can be operated with different versions of the AMOM adapter (see
sions).
The DIUN2 board automatically performs a reload after switching the connection type to load
the loadware for the connection type.