Replacing the Backplane
Replacing the backplane may be necessary due to contact problems. These are evidenced by
the following symptoms:
Error messages about various peripheral modules occur.
●
Erratic error messages about the CBCC/CBRC and UPSCD modules occur.
●
The system displays the error message B16-12 RESTART: Power down and performs
●
a restart.
Please note, however, that the backplane should only be replaced if the errors still occur even
after the following points have been checked and the mentioned problems eliminated:
Have the necessary grounding regulations been followed?
●
Do the cables have contact problems or visible damage?
●
Do the system components have any visible damage?
●
The following part numbers must be used to order the necessary replacement parts for HiPath
3500:
L37911-A10-A17:
S30777-Q751-Z:
Replacing the backplane is described in Section 4.2.5, "Replacing the Backplane".