Planning Load for HiPath Systems

This section describes a dimensioning method for the various systems. In order to provide for
sufficient reserves to handle load fluctuations during operations, a so-called planning load is
defined the systems. This planning load consists of 70 % of the capacity available for call pro-
cessing (switching) transactions (see Figure below).
Relative shares
(w/o basic load)
Figure 2-7
Planning Load for HiPath 3000/5000 Systems
The planning load values described here are taken into account in the following table as the
"maximum permissible points".
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Basic load
(e.g., polling)
Reserve for load fluctua-
tions
70 %
Planning load for call
processing
HiPath 3000
Dynamic Configuration Rules
100 %
Absolute shares
70 (1-basic load)%
sysdat.fm
System Data
2-55