Thumb Rule For Hg 1500 V3.0; Procedural Principles; Maximum Permissible Values For Hg 1500 V3.0; Current Thumb Rule Values - Siemens HiPath 3000 Series Service Documentation

Table of Contents

Advertisement

sysdat.fm
System Data
Dynamic Configuration Rules
2.5.3

Thumb Rule for HG 1500 V3.0

2.5.3.1

Procedural Principles

The thumb rule presented below for calculating the dynamic load for the HG 1500 board is
based on the principle of considering every functionality (HFA phone, IP trunking, gateway
channels, VPN tunnel, etc.) in terms of its CPU load.
2.5.3.2

Maximum Permissible Values for HG 1500 V3.0

For version V3.0, the following maximum permissible point totals are used as a basis for the
thumb rule:
Table 2-41
HG 1500 V3.0 Boards and Corresponding Maximum Points
HG 1500 Board
HXGS3, HXGR3
STMI2
2.5.3.3

Current Thumb Rule Values

The following table lists the interfaces taken into account in the thumb rule.
PDM Modules
Table 2-42
Points for the PDM Modules to Increase the DSP Number
System
System
PDM1
Signaling
Table 2-43
Points for Signaling
System
System
IP phones
Number of terminal devices connected via IP using HFA func-
without H.235
tionality or SIP (GK security is deactivated).
IP phones
Number of terminal devices connected via IP using HFA func-
with H.235
tionality (full or reduced GK security is activated).
2-62
Corresponding Systems
HiPath 3300/3350/3500/3550
HiPath 3800
Meaning
Number of PDM1 modules on the board
Meaning
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Maximum
Points
780
980
Weight
10
Weight
0.68 · F
Tln
0.78 · F
Tln