This example assigns a virtual MAC address to port 3 and displays the MAC addresses of the ports 2 ~ 4.
The assigned virtual MAC address should be unique in both the Switch and the network to which it
belongs.
sysname# config
sysname(config)# interface port-channel 3
sysname(config-interface)# ethernet cfm virtual-mac 00:19:cb:12:34:56
sysname(config-interface)# exit
sysname(config)# exit
sysname# show ethernet cfm virtual-mac port 2-4
Virtual MACPort MAC
---- -----------------
2
00:19:cb:00:00:02
3
00:19:cb:12:34:56
4
00:19:cb:00:00:02
sysname#
This example sets the Switch to carry its host name and management IP address 192.168.100.1 in CFM
packets.
sysname# config
sysname(config)# ethernet cfm management-address-domain ip 192.168.100.1
This example shows remote MEP database information. The remote MEP has been configured to carry its
host name and a specified IP address in CFM packets.
sysnam# show ethernet cfm remote
MD Index: 1
MD Name: customer123(string)
MD Level: 2
MA Index: 1
MA Name: 123(vid)
Primary Vlan: 123
MEP: 11
Remote MEP ID:
MAC Address: 00:19:cb:6f:91:5a
Chassis Id: MGS-3712F
Management Address: 192.168.100.1:161
sysname#