29.3 Command Examples
In this example, the administrator looks at the Switch's GARP timer settings and decides to change
them. The administrator sets the Join Timer to 300 milliseconds, the Leave Timer to 800 milliseconds, and
the Leave All Timer to 11000 milliseconds.
sysname# show garp
GARP Timer
------------------------
Join
Timer
Leave Timer
Leave All Timer
sysname# configure
sysname(config)# garp join 300 leave 800 leaveall 11000
sysname(config)# exit
sysname# show garp
GARP Timer
------------------------
Join
Timer
Leave Timer
Leave All Timer
Chapter 29 GARP Commands
:200
:600
:10000
:300
:800
:11000
Ethernet Switch CLI Reference Guide