Table 229 zuld Command Summary (continued)
COMMAND
zuld probe-time <5-65535>
show zuld [<port-list>]
show zuld summary
104.3 Command Example
This example enables Ethernet OAM on the Switch and ports 1-3 first, then enables ZULD on the Switch
and ports 1-3. It also sets a ZULD mode and displays the configuration details.
sysname# configure
sysname(config)# ethernet oam
sysname(config)# interface port-channel 1-3
sysname(config-interface)# ethernet oam
sysname(config-interface)# exit
sysname(config)# zuld
sysname(config)# interface port-channel 1-3
sysname(config-interface)# zuld
sysname(config-interface)# zuld mode aggressive
sysname(config-interface)# exit
sysname(config)# exit
sysname# show zuld 1-3
Port 1
Active
Mode
Probe Time
Link State
Port 2
Active
Mode
Probe Time
Link State
Port 3
Active
Mode
Probe Time
Link State
sysname#
Chapter 104 ZULD Commands
DESCRIPTION
Sets the length of time that ZULD waits before declaring
that a link is unidirectional. When the probe time expires,
and one port (either on the Switch or the connected
device) still has not received an OAMPDU, then ZULD
declares that the link is unidirectional.
Displays ZULD details and link state for all ports or the
specified port(s).
Displays ZULD details of each port in a summary table.
: Yes
: Aggressive
: -
: Linkdown
: Yes
: Aggressive
: -
: Linkdown
: Yes
: Aggressive
: -
: Linkdown