ZyXEL Communications XS3800-28 Cli Reference Manual page 241

Hide thumbs Also See for XS3800-28:
Table of Contents

Advertisement

Table 160 pwr Command Summary (continued)
COMMAND
pwr interface <port-list>
no pwr interface <port-list>
pwr interface <port-list> auto-pd-
recovery
no pwr interface <port-list> auto-
pd-recovery
pwr interface <port-list> auto-pd-
recovery action <reboot-
alarm|alarm>
pwr interface <port-list> auto-pd-
recovery mode <lldp|ping <ip>
[polling-interval <10-300>]
[polling-count <2-5>]>
pwr interface <port-list> auto-pd-
recovery pd-reboot-count <1-5>
pwr interface <port-list> auto-pd-
recovery resume-polling-interval
<60-800>
pwr interface <port-list> auto-pd-
recovery resume-power-interval <50-
120>
pwr interface <port-list> max-power
<1000-33000>
no pwr interface <port-list> max-
power
Chapter 63 PoE Commands
DESCRIPTION
Enables PoE (Power over Ethernet) on the specified
port(s).
Disables PoE (Power over Ethernet) on the specified
port(s).
Turns on auto PD recovery on the specified port(s).
Turns off auto PD recovery on the specified port(s).
Set the action to take when the connected PD has
stopped responding.
reboot-alarm
power of the connected PD and turn it back ON
again to restart the PD after sending an SNMP trap
and generating a log message.
alarm
generate a log message.
Sets whether the Switch uses LLDP or ping to check
current status of a connected PD.
lldp
status of the connected PD by reading LLDP packets
from the PD on the specified port(s).
ping
connected PD to test whether the PD is reachable or
not.
Sets how many times the Switch attempts to restart
the PD on the specified port(s).
Sets the number of seconds the Switch waits before
monitoring the PD status again after it restarts the PD
on the specified port(s).
Sets the number of seconds the Switch waits before
supplying power to the connected PD again after it
restarts the PD on the specified port(s).
Sets the maximum amount of power the PD could use
from the Switch on the specified port(s).
Note: The user-configured maximum power
Removes the maximum power settings for the
specified port(s). The PD(s) that is connected to the
port(s) then can use power up to the Switch's total
power budget.
Ethernet Switch CLI Reference Guide
241
: to have the Switch turn OFF the
: to have the Switch send an SNMP trap and
: to have the Switch passively monitor current
: to have the Switch ping the IP address of the
setting will not take effect when the
power-up mode is set to 802.3bt.
M
P
C
13
C
13
C
13
C
13
C
13
C
13
C
13
C
13
C
13
C
13
C
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents