where
1-65535
variable
interval-integer
absolute|delta
startup-alarm
rising-integer
rising-event-index
falling-integer
falling-event-index
owner
This example shows you how to configure an alarm using the following settings:
Chapter 75 RMON
This is an alarm's index number in the alarm table.
This is the variable(s) whose data is sampled. The allowed options are:
[ifType.<port>]
[ifMtu.<port>]
[ifSpeed.<port>]
[ifAdminStatus.<port>]
[ifOperStatus.<port>]
[ifLastChange.<port>]
[ifInOctets.<port>]
[ifInUcastPkts.<port>]
[ifInNUcastPkts.<port>]
[ifInDiscards.<port>]
[ifInErrors.<port>]
[ifInUnknownProtos.<port>]
[ifOutOctets.<port>]
[ifOutUcastPkts.<port>]
[ifOutNUcastPkts.<port>]
[ifOutDiscards.<port>]
[ifOutErrors.<port>]
[ifOutQLen.<port>]
[sysMgmtCPUUsage.<index>]
[sysMemoryPoolUtil.<index>]
[<OID>]
This is the time interval (in seconds) between data samplings.
This is the method of obtaining the sample value and calculating the value to be
compared against the thresholds.
absolute - the sampling value of the selected variable will be compared
directly with the thresholds.
delta - the last sampling value of the selected variable will be subtracted from
the current sampling value first. Then use the difference to compare with the
thresholds.
Specify when the Switch should generate an alarm regarding to the rising and/or
falling thresholds.
risingAlarm - the Switch generates an alarm if the sampling value (or
calculated value) is greater than or equal to the rising threshold.
fallingAlarm - the Switch generates an alarm if the sampling value (or
calculated value) is less than or equal to the falling threshold.
risingOrFallingAlarm - the Switch generates an alarm either when the
sampling value (or calculated value) is greater than or equal to the rising
threshold or when the sampling value (or calculated value) is less than or equal
to the falling threshold.
Specify an integer for the rising threshold. When the value is greater or equal to this
threshold, the Switch generates an alarm.
Specify an event's index number (between 0 and 65535). The Switch will take the
corresponding action of the selected event for the rising alarm. Set this to 0 if you
do not want to take any action for the alarm.
Specify an integer for the falling threshold. When the value is smaller or equal to this
threshold, the Switch generates an alarm.
Specify an event's index number (between 0 and 65535). The Switch will take the
corresponding action of the selected event for the falling alarm. Set this to 0 if you
do not want to take any action for the alarm.
Specify who should handle this alarm.