[E480] Bridge unit open jam
Is the Bridge unit open?
YES
Remove the paper if there is any, then close the unit.
NO
Is the bridge unit cover opening/closing detection switch working?
(Perform the input check: 03-[FAX]ON/[0]/[B])
|
NO
1) Check if the connector of the bridge unit cover opening/closing detection
|
|
2) Check if the connector CN353 on the LGC board is disconnected.
|
3) Check if the connector pins are disconnected or the harnesses are open
|
|
4) Check if the conductor pattern on the LGC board is short circuited or open
|
|
5) Replace the bridge unit cover opening/closing detection switch.
|
6) Replace the LGC board.
|
YES
Replace the LGC board.
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
switch is disconnected.
circuited.
circuited.
5 - 23
e-STUDIO281c/351c/451c
TROUBLESHOOTING
5