ABB IRB 760 Product Manual page 19

Hide thumbs Also See for IRB 760:
Table of Contents

Advertisement

To be observed by the supplier of the complete system
Complete manipulator
Safety risk
Hot components!
Removed parts may result in collapse of
manipulator!
Removed cables to the measurement sys-
tem
3HAC039838-001 Revision: C
1.2.3.1 Safety risks during installation and service work on manipulators
The axes are affected by the force of gravity when the brakes are released.
In addition to the risk of being hit by moving manipulator parts, there is a risk
of being crushed by the parallel arm (if there is one).
Energy stored in the manipulator for the purpose of counterbalancing certain
axes may be released if the manipulator, or parts thereof, are dismantled.
When dismantling/assembling mechanical units, watch out for falling objects.
Be aware of stored heat energy in the controller.
Never use the manipulator as a ladder, which means, do not climb on the
manipulator motors or other parts during service work. There is a serious
risk of slipping because of the high temperature of the motors and oil spills
that can occur on the manipulator.
The supplier of the complete system must ensure that all circuits used in the
safety function are interlocked in accordance with the applicable standards
for that function.
The supplier of the complete system must ensure that all circuits used in the
emergency stop function are interlocked in a safe manner, in accordance
with the applicable standards for the emergency stop function.
© Copyright 2013 ABB. All rights reserved.
Description
CAUTION
Motors and gears are HOT after running the
manipulator! Touching motors and gears may
result in burns!
With a higher environment temperature, more
surfaces on the manipulator will get HOT and
may also result in burns.
WARNING
Take any necessary measures to ensure that
the manipulator does not collapse as parts
are removed, e.g. secure the lower arm ac-
cording to repair instruction if removing mo-
tor, axis 2.
WARNING
If the internal cables for the measurement
system have been disconnected during repair
or maintenance, then the revolution counters
must be updated.
Continues on next page