ABB IRB 760 Product Manual page 122

Hide thumbs Also See for IRB 760:
Table of Contents

Advertisement

3 Maintenance
3.3.8 Inspecting, additional mechanical stops
Continued
2
3
4
122
Action
Check additional stops on axis 1 for damage.
Make sure stops are properly attached.
Correct tightening torque, mechanical stops:
Axis 1 = 115 Nm
If any damage is detected, the mechanical stops
must be replaced!
Correct attachment screws:
Axis 1: M16 x 35, quality 12.9.
© Copyright 2013 ABB. All rights reserved.
Note
Shown in figure
Location of
mechanical stops on page
Art. no. is specified in
Required
equipment on page
121.
3HAC039838-001 Revision: C
121.