3.4
Home Position Return Data
The home position return data is used to perform the home position return.
[Motion Control Parameter] [Axis Setting Parameter] "Home Position Return Data"
No. Item
Default
value
1
Home position
0
return direction
2
Home position
2
return method
3
Home position
0 [pulse]
address
4
Home position
return speed
5
Creep speed
6
Travel value
after proximity
dog ON
7
Parameter
block setting
8
Home position
return retry
function
9
Dwell time at
the home
position return
retry
10
Home position
shift amount
11
Speed set at
the home
position shift
12
Torque limit
value at the
creep speed
3 PARAMETERS FOR POSITIONING CONTROL
178
3.4 Home Position Return Data
Setting range
mm
inch
0: Reverse direction (Address decrease direction)
1: Forward direction (Address increase direction)
0: Proximity dog method 1
4: Proximity dog method 2
1: Count method 1
5: Count method 2
6: Count method 3
2: Data set method 1
3: Data set method 2
14: Data set method 3
7: Dog cradle method
8: Stopper method 1
9: Stopper method 2
10: Limit switch combined method
11: Scale home position signal detection method
12: Dogless home position signal reference method
13: Driver home position return method
-2147483648
-2147483648
to 2147483647
to 2147483647
-1
-5
(10
[m])
(10
[inch])
1 to
1 to
600000000
600000000
-2
-3
(10
[mm/
(10
[inch/
min])
min])
1 to
1 to
600000000
600000000
-2
-3
(10
[mm/
(10
[inch/
min])
min])
0 to
0 to
2147483647
2147483647
-1
-5
(10
[m])
(10
[inch])
1 to 64
0: Invalid (Do not execute the home position return retry by limit
switch.)
1: Valid (Execute the home position return retry by limit switch.)
0 to 5000 [ms]
-2147483648
-2147483648
to 2147483647
to 2147483647
-1
-5
(10
[m])
(10
[inch])
0: Home position return speed
1: Creep speed
-1
1 to 10000 (10
[%])
degree
pulse
0 to 35999999
-2147483648
-5
(10
to 2147483647
[degree])
[pulse]
1 to
1 to
2147483647
2147483647
-3
(10
[degree/
[pulse/s]
*3
min])
1 to
1 to
2147483647
2147483647
-3
(10
[degree/
[pulse/s]
*3
min])
0 to
0 to
2147483647
2147483647
-5
(10
[pulse]
[degree])
-2147483648
-2147483648
to 2147483647
to 2147483647
-5
(10
[pulse]
[degree])
*2
Direct
Indirect setting
*1
setting
Valid/
Valid/
Fetch
invalid
invalid
cycle
(Required
size)
(2 word)
At the
home
position
return
(2 word)
start
(2 word)
(2 word)
(1 word)
At the
home
position
return
start
(2 word)
(1 word)
At the
home
position
return
start
Reference
Section
Page
179
Page
180
Page
180
Page
180
Page
180
Page
181
Page
182
Page
183
Page
184
Page
185