iX4-280/380 Series Printer
User Manual
Printing Media Calibration &
3.2
Configuration
Before calibration, be sure media and ribbon (for thermal transfer printing) have
been loaded correctly. The label sensor needs to locate properly to index labels'
gaps/ notches/ holes. After the media is loaded, please perform media calibration to
calibrate the label sensor in advance. For non-LCD printers, see Indicators.
1. Turn off the printer.
2. Press and hold the PAUSE button and turn on the power.
3. When "CALIBRATION ..." is displayed on the LCD, and both READY and MEDIA
indicators blink, release the PAUSE button.
4. The printer feeds 1 or 2 blank labels.
5. When "READY" is displayed, the READY and MEDIA indicators stop blinking
but remain illuminated.

3.3 Printing a Configuration Report

Perform a self-test and print a configuration report to check the printer's print quality
and internal settings. Follow the steps below:
1. Turn off the printer.
2. Load media and ribbon.
3. Press and hold the FEED button while turning on the power.
4. When "SELF-TEST ..." is displayed on the LCD, release the FEED button.
5. The printer will now print a configuration report, as shown in the example on
the next page. All characters will be printed in 2 columns: the right shows
characters received from your system, and the left are the corresponding
hexadecimal values of the characters. It allows users or engineers to verify
and debug the program.
For non-LCD printers, see Indicators.