REP 15.2.16 End Wall Motor
Parts List on
PL 18.15
Removal
To avoid personal injury or shock, disconnect the Finisher cable connector. Switch off
the machine power and disconnect the machine Power Cord.
1.
Switch off the printer power and disconnect the AC Power Cord.
2.
Remove the Stapler Cover Assembly
3.
Remove the End Wall Motor
(Figure
1.
Remove the screws (2) securing the Harness Holder to the Finisher frame and push
the wire harness to one side.
2.
Remove the End Wall Spring.
3.
Remove the screws (2) securing the End Wall Motor Bracket to the finisher frame.
Remove the Bracket along with the attached End Wall Motor.
4.
Release the end Wall Motor wire harness from the harness clips.
5.
Disconnect the End Wall Motor wire harness at the back of the motor or disconnect
P/J1083.
6.
Remove the screws (2) securing the End Wall Motor to the Bracket, and remove the
Motor.
Figure 1 Remove the End Wall Motor
Finisher/Sorter
REP 15.2.16
WARNING
(REP
15.3.3).
1).
Replacement
1.
Reinstall the End Wall Motor onto the Motor Bracket.
2.
Reconnect the End Wall Motor Wire Harness.
3.
Reinstall the End Wall Motor Bracket onto the Finisher frame, making sure the End Wall
Link is captured inside the End Wall Motor yoke.
4.
Connect the End Wall Motor Connector P/J1083.
5.
Use the screws (2) to secure the End Wall Motor Bracket to the Finisher frame.
6.
Reinstall the End Wall Spring, with one end of the Spring attached to the End Wall
7.
Install the Stapler Cover Assembly.
1/05
8d-92