Remove the Stacker Motor Belt. Enter dC330012-041 Stacker Motor Down and press
Start. The Stacker Motor rotates.
Y
N
Go to
Flag 15
and
Flag 16
on BSD 12.15 Check for an open circuit or a short to
GND. If the wires are good, replace the Stacker Motor
tinues, replace the Finisher PWB
Ensure that the gears in the Stacker Motor Assembly are installed correctly, and are free
from damage.
Ensure that the Front and Rear Stacker Tray Drive Belts are installed correctly (refer to
REP
15.2.9).
The problem appears to be intermittent. Go to
BSD 12.15. Check the circuits of the Stacker Motor and the Stacker Upper Limit Sensor for a
loose connection or an intermittent short circuit to GND.
Reissue
DocuColor 12/DCCS50
(PL
18.26) If the problem con-
(PL
18.4).
Flag
3,
Flag
4,
Flag
7,
Flag
15, and
Flag 16
12-256 RAP
The Stacker Lower Limit Sensor detects the Stacker Tray at the lower limit during ascension, or
does not detect a change of state during ascension.
Initial Actions
Refer to BSD 12.1 and 12.15 for the following procedure
Procedure
Remove the Rear Lower Cover. The Stacker Lower Limit Sensor is blocked by the Actua-
tor.
Y
N
on
Enter dC330 012-260 Stacker Lower Limit Sensor. Press Start. Manually actuate the
Stacker Lower Limit Sensor. The display changes from Low to High to Low.
Y
N
The display is always Low.
Y
N
Disconnect P/J1066. There is +5 VDC from J1066-1 to J1066-3.
Y
N
+5 VDC is measured from P/J1038-5 to P/J1038-6.
Y
N
+5 VDC is measured from P/J1026-3 to P/J1026-2.
Y
N
Go to
open circuit.
Replace the Finisher PWB
Go to
Flag 5
cuit.
There is +5 VDC from J1066-2 to J1066-3.
Y
N
Go to
Flag 6
wire is good, replace the Finisher PWB
Replace the Stacker Upper Limit Sensor
replace the Finisher PWB
Disconnect P/J1066. The display is High.
Y
N
Go to
Flag 6
and
GND. If the wire is good, replace the Finisher PWB
Replace the Stacker Lower Limit Sensor
Go to
Flag 5
and
Flag 6
on BSD 12.15. Check for a loose connection or an intermittent
short circuit to GND. If the wires are good, replace the Stacker Lower Limit Sensor
18.27).
Enter dC330 012-040 Stacker Motor Up and press Start. The Stacker Tray moves up.
1/05
8d-47
Flag 17
on BSD 12.1. Check the +5VDC wiring for an
(PL
18.4).
and
Flag 7
on BSD 12.15. Check the harness for an open cir-
on BSD 12.15. Check the harness for an open circuit. If the
(PL
18.4)
(PL
18.27). If the problem continues,
(PL
18.4).
Flag 7
on BSD12.15. Check the wire for a short circuit to
(PL
18.4)
(PL
18.27).
12-255, 12-256