BULLETIN NUMBER:
APPLICABLE MODEL:
GESTETNER – 9002/10512
LANIER – LD090/LD0105
RICOH – AFICIO 2090/2105
SAVIN – 4090/40105
SUBJECT: E32 OR E44 OCCUR DURING FIRMWARE UPDATE
SYMPTOM:
Error codes E32 and E44 are sometimes displayed when several firmwares are installed simultaneously.
NOTE:
These codes cannot be cleared powering the unit OFF/ON.
CAUSE:
A firmware transmission error may occur when installing several types of firmware simultaneously. Since the
error data is saved to the NVRAM, the machine is unable to boot up normally, even after the main switch is
turned OFF/ON.
SOLUTION:
Clear the error code with the following procedure and re-install the firmware again.
1. Press  ("1", "4", "3" key) on the operation panel when the error codes appear.
2. Press
("Clear" key) three times.
C
The machine will indicate the error has been cleared with a beep.
 Important Notice
To ensure the above error codes do not occur, please be sure to follow the procedure below whenever
installing several kinds of firmware at the same time:
1. Before installing any firmware, install the "System" firmware individually.
2. After successfully installing the "System" firmware, turn the machine main power OFF/ON and confirm
that the machine boots up to Ready status normally.
3. The remaining firmware may now be installed simultaneously.