2.10.7 FUSING PRESSURE

[A]
[D]
A294D557.WMF
[F]
Fusing pressure is constantly applied between the hot roller [A] and pressure roller
[B] by the upper pressure lever [C] and lower pressure lever [D], which are lifted by
the fusing unit release lever [E] via the pressure cam [F]. The pressure can be
adjusted by using the pressure adjustment screw [G].
The fusing pressure is released by turning the fusing unit release lever
counterclockwise.