Gestetner B070 Service Manual page 1068

Table of Contents

Advertisement

BULLETIN NUMBER:
APPLICABLE MODEL:
GESTETNER – 9002/10512
LANIER – LD090/LD0105
RICOH – AFICIO 2090/2105
SAVIN – 4090/40105
SUBJECT: SEAL IMPROVEMENTS IN THE TONER BANK UNIT
SYMPTOM:
The following conditions may occur:
1.
Misdetection of the Waste Toner Bottle Full Condition.
2.
The Toner Bottle cannot be pulled out from the Toner Bank Unit.
CAUSE:
1. Misdetection of the Waste Toner Bottle Full Condition
Toner may fall onto the outer portion of the toner bank unit when the toner bottle chuck opens the toner
bottle. The falling toner covers the detection area of the toner over flow sensor, causing it to misdetect the
Waste Toner Bottle Full Condition.
2. Toner bottle cannot be pulled out from the Toner Bank Unit
When toner is supplied to the toner bank unit, it may leak out from the bottle and gradually accumulate in the
chuck area, eventually preventing the bottle-holding mechanism on the chuck from releasing the bottle.
Copyright  2004 RICOH Corporation. All rights reserved.
CÓPIA NÃO CONTROLADA
TECHNICAL SERVICE BULLETIN
B070/B071 – 026
CÓPIA NÃO CONTROLADA
1/22/2004
Page 1 of 4

Advertisement

Table of Contents
loading

This manual is also suitable for:

B071

Table of Contents