Tech Service Bulletin No. B070/B071 – 035
SP2602
PTL Settings
004
Back – On/Off Timing
Adj.
Front – On/Off Setting:
005
Low Speed Mode
006
Front – Off Timing Adj.:
Low Speed Mode
007
Back– On/Off Setting:
Low Speed Mode
008
Back – Off Timing Adj.:
Low Speed Mode
CÓPIA NÃO CONTROLADA
This SP adjusts the length of the space from the leading edge
where the PTL quenching is applied to the back side at normal
speed. For example, if you set +5, 5 mm from the leading
edge will be quenched.
[-5~10/2/0.1 mm]
Switches the PTL on and off for the front side of the paper
passing through the fusing unit at in the low speed mode.
Note: When feeding thick paper or OHP transparencies, this
setting is always off.
[0~1/0/1]
0: Off
1: On
This SP adjusts the length of the space from the leading edge
where the PTL quenching is applied to the front side in low
speed mode. For example, if you set +5, 5 mm from the
leading edge will be quenched.
[-5~10/2/0.1 mm]
Switches the PTL on and off for the back side of the paper
passing through the fusing unit in the duplex mode in low
speed mode.
[0~1/0/1]
0: Off
1: On
Note:
When this setting is switched on, make sure that the
setting of SP2940 016 is the same as the default setting
of SP2940 009.
When feeding thick paper or OHP transparencies, this
setting is always off.
This SP adjusts the length of the space from the leading edge
where the PTL quenching is applied to the back side in slow
speed mode. For example, if you set +5, 5 mm from the
leading edge will be quenched.
[-5~10/2/0.1 mm]
CÓPIA NÃO CONTROLADA