Tech Service Bulletin No. B070/B071 – 035
3. FUSING TEMPERATURE RANGE:
The adjustable temperature range for the fusing unit has been changed as follows.
SP
B070: [168 ~ 178 / 168 / 1 deg]
SP1105-001
B071: [168 ~ 178 / 173 / 1 deg]
B070: [148 ~ 158 / 148 / 1 deg]
SP1105-002
B071: [148 ~ 158 / 153/ 1 deg]
NOTE:
The default value for the of the new enhanced versions have not changed
4. NEW PRE-TRANSFER LAMP:
A new pre-transfer lamp (PTL) has been added to the B070/B071 enhanced models. The PTL has been
added to aid in poor drum separation problems, but if the PTL is used a blurred image may appear on the
leading edge of the paper. Therefore, the default setting for the PTL is set to "Off."
The following service programs have been added for the new pre-transfer lamp.
SP2602
PTL Settings
001
Front – On/Off Setting
002
Front – Off Timing Adj.
003
Back – On/Off Setting
CÓPIA NÃO CONTROLADA
Old Function/[Setting]
Switches the PTL on and off for the front side of the paper
passing through the fusing unit at normal speed.
Note: When feeding thick paper or OHP transparencies, this
setting is always off.
[0~1/0/1]
0: Off
1: On
PTL timing can be adjusted with SP2602 002.
This SP adjusts the length of the space from the leading edge
where the PTL quenching is applied to the front side at normal
speed. For example, if you set +5, 5 mm from the leading
edge will be quenched.
[-5~10/2/0.1 mm]
Switches the PTL on and off for the back side of the paper
passing through the fusing unit in the duplex mode at normal
speed.
[0~1/0/1]
0: Off
1: On
Note:
When this setting is switched on, make sure that the
setting of SP2940 008 is the same as the default setting
of SP2940 001.
When feeding thick paper or OHP transparencies, this
setting is always off.
CÓPIA NÃO CONTROLADA
New Function/[Setting]
B070E: [120 ~ 178 / 168 / 1 deg]
B071E: [120 ~ 178 / 173 / 1 deg]
B070E: [100 ~ 158 / 148 / 1 deg]
B071E: [100 ~ 158 / 153/ 1 deg]