RADIUS Protocol Configuration Commands
329
View
RADIUS scheme view
Parameter
data: Sets data unit.
byte: Sets 'byte' as the unit of data flow.
giga-byte: Sets 'giga-byte' as the unit of data flow.
kilo-byte: Sets 'kilo-byte' as the unit of data flow.
mega-byte: Sets 'mega-byte' as the unit of data flow.
packet: Sets data packet unit.
giga-packet: Sets 'giga-packet' as the unit of packet flow.
kilo-packet: Sets 'kilo-packet' as the unit of packet flow.
mega-packet: Sets 'mega-packet' as the unit of packet flow.
one-packet: Sets 'one-packet' as the unit of packet flow.
Description
Use the data-flow-format command to configure the unit of data flow that send
to RADIUS Server.
Use the undo data-flow-format command to restore the unit to the default
setting.
By default, the data unit is byte and the data packet unit is one-packet.
Related command, see display radius.
Example
# Set the unit of data flow that send to RADIUS Server 3Com is kilo-byte and the
data packet unit is kilo-packet.
[3Com-radius-3com] data-flow-format data kilo-byte packet kilo-packet

debugging radius

Syntax
debugging radius packet
undo debugging radius packet
View
User view
Parameter
packet: Enable packet debugging