3Com 8807 Command Reference Manual page 894

8800 series
Hide thumbs Also See for 8807:
Table of Contents

Advertisement

892
C
51: P
E PSU S
HAPTER
O
C
UPERVISION
OMMANDS
View
Any view
Parameter
None
Description
Use the display supervision-module information command to display the
name of the supervision module, power supply model, specifications and output
power, and other information.
Example
# Display current information about the power system
<SW8800> display supervision-module information
Supervision Module Version
Supervision Module Name
Power Type
:PSE4500-A
Power Rating Value
Power Current Value
Power Remaining Value : 2197 W
Power Peak Value
Power Average Value
PSU Number
PSU 1
Rating Output Power
Hard Version Info
PSU 2
Rating Output Power
Hard Version Info
Table 123 Description on the fields of the display supervision-module information
command
Field
Supervision Module Version Software version of the supervision module
Supervision Module Name
Power Type
Power Rating Value
Power Current Value
Power Remaining Value
Power Peak Value
Power Average Value
Rating Output Power
: 2.0
:Spring Pms
: 2250 W (220V)/1125 W(110V)
: 53 W
: 0 W
: 0 W
: 2
: 2500 W
:NP 2500
: 2500 W
:NP 2500
Description
Name of the supervision module
Power type
Rated power of the power system
Current consumption power of the power system
Current remaining power of the power system
Peak power of the power system
Average power of the power system
Rated output power. When one or two PSUs are available, it is
2250 W for 220 VAC input and 1125 W for 110 VAC input.
When three PSUs are available, it is 4500 W for 220 VAC input
and 2250 W for 110 VAC input.