Display Poe Interface Power - 3Com 8807 Command Reference Manual

8800 series
Hide thumbs Also See for 8807:
Table of Contents

Advertisement

880
C
50: P
E C
HAPTER
O
ONFIGURATION
n
display poe interface
power
C
OMMANDS
Table 118 Description on the fields of the display poe interface command
Field
Description
PoE status of the port:
1 disabled: PoE is disabled on the port.
2 searching: the port is searching for a PD.
Port power status
3 delivering: the port is supplying power to the PD.
4 PD disconnected: the port is not connected with a PD.
5 testing: the port is in testing.
6 fault: the port detected an nonstandard or fault PD.
PoE mode of the port:
1 auto: the system automatically selects the PoE mode.
Port power mode
2 signal
3 spare
Port PD class
The class of the power the port supplies to the PD
Port priority:
1 critical (the highest)
Port power priority
2 high
3 low
Port max power
Maximum power on the port
Port current power
Present power on the port
Port average power
Average power on the port
Port peak power
Peak power on the port
Port current
Present current on the port
Port voltage
Present voltage on the port
Port remaining
Remaining power on the port
power
The sampling cycle of the power, current and voltage of ports is 1 second;
The sampling cycle of the peak power and average power of ports is 5 minutes
Syntax
display poe interface power [ interface-type interface-num ]
View
Any view
Parameter
interface-type interface-num: Port type and port number; refer to Command
Manual - Port for details.
Description
Use the display poe interface power interface-type interface-num command to
display the PoE power information of the specified port on the switch. If you enter