Timer Response-Timeout; User-Name-Format - 3Com 8807 Command Reference Manual

8800 series
Hide thumbs Also See for 8807:
Table of Contents

Advertisement

RADIUS Protocol Configuration Commands
351

timer response-timeout

Syntax
timer response-timeout seconds
undo timer response-timeout
View
RADIUS scheme view
Parameter
seconds: The value range is 1 to 10 in seconds. The default response timeout value
of the RADIUS server is 3 seconds.
Description
Use the timer response-timeout command to set the response-timeout value of
RADIUS server.
Use the undo timer response-timeout command to restore the default
configuration.
Related command: display radius.
Example
# Set the response timeout value of the RADIUS server to 5 seconds.
[SW8800] radius scheme test1
[3Com-radius-test1] timer response-timeout 5

user-name-format

Syntax
user-name-format { with-domain | without-domain }
View
RADIUS scheme view
Parameter
with-domain: Specifies to send the username with domain name to RADIUS
server.
without-domain: Specifies to send the username without domain name to
RADIUS server.
Description
Use the user-name-format command to configure the username format sent to
RADIUS server.
By default, as for the newly created RADIUS scheme, the username sent to
RADIUS servers includes an ISP domain name; as for the "system" RADIUS scheme
created by the system, the username sent to RADIUS servers excludes the ISP
domain name.
The supplicants are generally named in userid@isp-name format. The part
following "@" is the ISP domain name. The switch will put the users into certain
ISP domains according to the domain names. However, some earlier RADIUS

Hide quick links: