<SW8800> system-view
System View: return to User View with Ctrl+Z.
[SW8800] link-status hold 5

interface

Syntax
interface interface-type interface-number
View
System view
Parameter
interface-type: Specifies the port type. It can be Aux, Ethernet, Loopback,
M-Ethernet, NULL, VLAN-interface, GigabitEthernet or 10-GigabitEthernet.
interface-number: Specifies the port number. It adopts
slot-number/subslot-number/ port-number format. slot-number specifies the I/O
Module slot number of the port. For Switch 8807, it ranges from 2 to 6. For
Switch 8810, it ranges from 0 to 3 and 6 to 9 (slot number 4 and 5 are Fabric). For
Switch 8814, it ranges from 0 to 5 and 8 to 13 (slot number 6 and 7 are Fabric).
subslot-number specifies the sub-slot number of the port and ranges from 1 to 3.
port-number specifies the port number on the daughter card. It is 1 or ranges
from 1 to 12, 20, or 48, depending on the module type. M-Ethernet is used to
update and maintain. It ranges from 0/0/0.
Description
Use the interface command to enter various types of Ethernet port views.
Before you can configure the related parameters of a type of Ethernet port, you
must first use this command to enter the Ethernet port view of this type.
Example
# Enter the Ethernet2/1/1 port view.
<SW8800> system-view
System View: return to User View with Ctrl+Z.
[SW8800] interface ethernet2/1/1

jumboframe enable

Syntax
jumboframe enable [ jumboframe-value ] slot slot-num
undo jumboframe enable
View
System view
Parameter
slot-num: Specifies the slot number of the card.
jumboframe-value: specifies the maximum size of jumbo frames permitted to pass
the card.