display poe-power
dc-output value
display poe-power
switch state
display
supervision-module
information
Syntax

display poe-power dc-output value

View
Any view
Parameter
None
Description
Use the display poe-power dc-output value command to display the DC
output voltage/current value of the PoE PSUs.
Example
# Display the DC output voltage/current value of the PoE PSUs.
<SW8800> display poe-power dc-output value
DC Output Voltage : 53.997 V
DC Output Current : 0.000 A
Syntax

display poe-power switch state

View
Any view
Parameter
None
Description
Use the display poe-power switch state command to display the number and
current state of the AC power distribution switches of the PSUs.
Example
# Display the number and current state of the AC power distribution switches.
<SW8800>display poe-power switch state
Switch Number : 0
Table 122 Description on the fields of the display poe-power switch state command
Field
Description
On
The switch is on.
Off
The switch is off.
High Volt Input The input is high voltage.
Low Volt Input
The input is low voltage.
Syntax

display supervision-module information

PoE PSU Supervision Display Commands
891