OVERVIEW
Category:
Primary context:
Related Commands
Usage: sflow <RECEIVER-INSTANCE> destination <IP-ADDRESS> [UDP-PORT]
sflow <RECEIVER-INSTANCE> polling [ethernet] PORT-LIST
sflow <RECEIVER-INSTANCE> sampling [ethernet] PORT-LIST
[no] sflow <RECEIVER-INSTANCE>
Description: Configure or un-claim an sflow sampling receiver.
Parameters:
COMMAND STRUCTURE
■ [no] sflow
sflow-receiver
(p. 510)
destination
■
sflow-udp-port
■
receiver/collector/management station. (NUMBER)
polling
-- Specify the ports for which packets are to be polled. ([ethernet] PORT-LIST)
■
sflow-polling-interval
■
between polling of counters.
sflow-polling-int-off
■
sampling
■
509)
sflow-sampler-off
■
sflow-sampler-rate
■
sampled.
© 2009 Hewlett-Packard Development Company, L.P.
config
<POLLING-INTERVAL>
<SAMPLING-RATE>
If the [no] option is not used, this command will
configure the sflow sampling receiver, polling,
and sampling.
IP-ADDRESS - Ip address of the sFlow
receiver/collector/management station
UDP-PORT - The udp application port of the sFlow
receiver/collector/management station (default: 6343).
POLLING-INTERVAL - The maximum interval (seconds) between
polling of counters. (a value of 0 causes polling to be
disabled.
PORT-LIST - Port(s) for which packet are to be sampled.
RECEIVER-INSTANCE - One of three posible sFlow receiver tables.
SAMPLING-RATE - N, where 1/N is the number of packets sampled.
(a value of 0 causes sampling to be disabled.)
< 1 to 3 > -- Select one of three possible sFlow receiver tables. (NUMBER)
-- IP address of sFlow receiver/collector/management station. (IP-ADDR)
< 1 to 65535 > -- UDP application port of sFlow
< 20 to 2147483647 > -- Specify the maximum interval (seconds)
< 0 > -- Disable polling of counters.
-- Specify the ports for which packets are to be sampled. ([ethernet] PORT-LIST)
< 0 > -- Disable sampling.
< 50 to 16441700 > -- Specify N, where 1/N is the number of packets
(p. 510)
(p. 510)
(p. 509)
(p. 510)
sflow
(p. 509)
(p. 509)
(p. 509)
(p.
508